Cooper Lighting ELVSTPP66344KZ, VSTPP66344KZ Installation Instructions

Instruction Leaflet
K1112V
November 2016
Instruction Manual - K1112V November 2016
VersaPanel
VersaPanel
Product luminaires comply with BSEN60598 Class1/Class 2.
This luminaire has an ambient temperature range of 5C to 25C
1
Typical 600x600mm
Suspended Ceiling Grid
Ceiling Tile
Remove the ceiling tile from the position the LED Panel is to be installed
3
IP44
2
ENSURE MAINS SUPPLY IS SWITCHED OFF
Class I Product
Wire LED Driver to mains supply,
Live, Eath and Neutral
IMPORTANT NOTE:
accordance with local wiring
LUMINAIRE MUST BE EARTHED
Class II Product
Wire to Live & Neutral on LED driver
(Brown)
(Blue)
Position Driver on ceiling tile next to LED Panel
4
ENSURE MAINS SUPPLY IS SWITCHED OFF
cables.
ermination to be in
T
Live (Brown)
Earth (Yellow/Green)
Neutral (Blue)
L N
connect the
regulations
Safe Operation
2. Ensure that the mains supply is switched off when working on this luminaire, whether installing or carrying out any other servicing.
3. To prevent damage to driver, do not mix with conventional magnetic ballasts on the same electrical circuit.
4. Where use in more onerous situations is required, e.g. In part-completed buildings before “drying-out” is completed, or areas where ambient temperatures are outside the normal temperature range, then consult our Sales Office.
Servicing and Disposal
1. At commissioning and handing over of installation ensure that a copy of these instructions is presented to the authority responsible for the operation and maintenance of the luminaries.
2. Servicing, e.g. cleaning, must only be carried out after the electricity supply has been switched off. It must not be assumed that luminaries with lamps not lit are switched off-always check before servicing.
3. Cleaning should be carried out at regular intervals to ensure that dirt does not accumulate to an extent that will impair the thermal safety or optical performance of the luminaire. Regular cleaning will also ensure that the optical performance of the luminaries is maintained.
4. Avoid touching the LED array surface. To clean - Blow surface with either dry air or nitrogen gas.
5. At the end of life the luminaire is classed as WEEE under directive 2002/96/EC and should be disposed of in accordance with local legislation.
Luminaire Cleaning
End of Life and Components Disposal
Move LED Panel into aperature in ceiling and position halfway. Take note of the below points:
1. Before installation ensure that the ceiling support system is adequate to carry total LED Panel weight.
2. Ensure prepared ceiling aperature will accommodate the LED Panel dimensions for installation.
Connect the driver to the LED Panel
1. Position LED Panel fully in aperature.
2. Ensure LED Panel rests fully on ceiling grid.