Cooper Lighting VRX User Manual

COOPER LIGHTING - SURE-LITES
4 7/8"
(124mm)
2 1/4"
(57mm)
1"
(26mm)
®
VRX SERIES
Thin Profile High-Abuse
AC Only Self-Powered
EXIT LIGHTING
• Dual-voltage input 120/277
INDUSTRIAL & HAZARDOUS LOCATION Exit Signs
VAC, 60 Hz
• Die cast aluminum faceplate exposed unit thickness is 1”
• 20 gauge recessed housing fits in 2x4 construction
• 18 gauge mounting plate with clearance holes for 1/4" fasteners
• LED lamp panel provides uniform light output
• Convex .125" polycarbonate Vandal Shield standard
• Centerpin Torx tamper resistant screws
DESCRIPTION
The VRX Thin Profile High-Abuse
DIMENSIONS
AC ONLY/SELF-POWERED REMOTE POWERED
Exit Series combines the strength of die cast aluminum, the profile of a recessed design and the superior aesthetics of Sure- Lites LED technology to create an exit with optimum
8 11/16" (221mm)
versatility and aesthetics. The VRX Series faceplate/mounting plate/lens is only 1" thick, yielding a sign with minimal
14" (356mm)
off-wall protrusion without requiring the large wall opening of a fully recessed exit. The VRX
1" (26mm)
Series also includes a Remote Powered Exit which can be powered from a VRX Series AC Only or Self Powered Exit.
ORDERING INFORMATION - AC ONLY EXITS / SELF-POWERED EXITS
SAMPLE NUMBER: VRX610000RB
Product Family VRX=Thin
Profile, High Abuse
ORDERING INFORMATION - REMOTE POWERED LED EXITS
SAMPLE NUMBER: VRX810000RB
Series 6=AC Only,
LED
7=Self-
Powered, LED
Face Options 1=Single
10 3/4" (273mm)
Battery 00=AC Only,
120/277 (VRX6 only)
70=Nickel
Cadmium Battery (VRX7 only)
Factory Options 00=No Options 20=Flasher
(VRX7 only)
30=Flasher/
Buzzer
(VRX7 only)
90=DC Fire
Alarm Interface (VRX7 only)
95=AC Only,
Fire Alarm Interface (VRX6 only)
2 1/4"
(57mm)
Letter Colors R=Red G=Green
Faceplate Finishes Blank=Brushed
Aluminum Face with Black Trim
W=White B=Black
1"
(26mm)
(26mm)
1"
664
• NFPA compliant knockout chevrons allow quick conversion to directional signs
• Adjustable hanger bars
• EPDM shock-absorbing gasket between mounting plate and wall
• Self-powered Exits feature line-latching, solid-state voltage limited charger, solid-state switching, low-voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/ power indicator light
• UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, UL Listed as suitable for floor proximity installation, most state and local codes
COOPER LIGHTING
Product Family VRX=Thin
Profile, High-Abuse
Energy Data
Series 8=Remote,
LED
Face Options 1=Single
Battery 00=Remote
Powered
Factory Options 00=No Options
Letter Colors R=Red G=Green
Faceplate Finishes Blank=Brushed
Aluminum Face with Black Trim
W=White B=Black
LED EXITS-AC ONLY
Input Power; Input Current (Max.): Power Factor: T.H.D.:
120V 277V 120V 277V 120V 277V 120V 277V
Red Letters Single Face 5.6W 5.7W .07A .03A >.71 >.71 <36% <36% Red Letters Single Face with Remote 7.3W 7.3W .07A .03A >.83 >.83 <33% <34% Green Letters Single Face 6.7W 6.8W .07A .03A >.79 >.79 <30% <31% Green Letters Single Face with Remote 9.5W 9.7W .09A .04A >.90 >.90 <26% <27%
Remote Powered
Red Letters Single Face 2.0 watts additional Green Letters Single Face 2.5 watts additional
Energy Data
Sealed Nickel Cadmium Battery-LED Exit
Input Power; Input Current (Max.): Power Factor: T.H.D.:
120V 277V 120V 277V 120V 277V 120V 277V
Red Letters Single Face 7.4W 7.5W .08A .04A >.72 >.72 <34% <34% Red Letters Single Face with Remote 9.3W 9.5W .08A .04A >.84 >.84 <31% <32% Green Letters Single Face 8.5W 8.7W .09A .04A >.79 >.79 <30% <31% Green Letters Single Face with Remote 11.4W 11.7W .11A .05A >.90 >.90 <26% <26%
Loading...