INSTALLATION INSTRUCTIONS
STEALTH GRAZE
STEALTH GRAZE
V90181
V90181
Avoid Fire or Electric Shock
*Installation Instructions for qualified electricians only.
*Install per National Electrical Code and local regulations.
*Read Installation Instructions completely before installation.
*Failure to follow Installation Instructions may void warranties.
FIXTURE MOUNTING
FIXTURE MOUNTING
1. Before Stealth Graze can be installed, blocking should be
1. Before Stealth Graze can be installed, blocking should be
installed above ceiling around the fixture. (Figure 1)
installed above ceiling around the fixture. (Figure 1)
Vertical Wall
(Grazed Surface)
Ceiling
FIXTURE MOUNTING
FIXTURE MOUNTING
Thermal
Bracket
Thermal
Protector
U
L
R
C
Thumb Screw
US
Blocking
FIGURE 1
2. The Trim of the Stealth Graze must now be removed so that
access can be gained to the Thermal Protector. This step may
be skipped if blocking is not in the way of the Thermal
Protector or a different mounting method is being used. Place
the Utility Wedge between the Trim and the Plaster Frame and
push straight up until the Trim pops out. (Figure 2) Do not
bend the Utility Wedge while in the Fixture, as it might break.
Thermal Protector
Trim
Plaster Frame
3. Once the Trim is removed, the Thermal Protector should be
pulled inside the Housing so that the Fixture will slide past
the Blocking. To do this, reach inside the Housing, unscrew
the Thumb Screw, and pull the Thermal Bracket (with the
Thermal Protector attached) into the Housing. (Figure 3)
The Fixture can now be hoisted into the ceiling for mounting.
Utility Wedge
FIGURE 2
Housing
4a.If two or more Stealth Graze Housings are being used, align
Housings into Ceiling, butting fixtures end to end tightly. Place
two (2) Connecting Screws through Connecting Holes on
Housings, and secure with Connecting Nuts. (Figure 4)
4b.Once the Fixture is placed into the ceiling, it can be secured
using countersunk screws. Fixture should be mounted by
screwing through the Plaster Frame (screw holes are already
countersunk) and into the blocking. (Figures 5 & 6) If additional
screw locations are needed, there is a screw line in the Plaster
Frame extrusion to facilitate this process.
Connecting Screws
Housing A
Housing B
FIGURE 3
FIGURE 4
Connecting
Holes
Connecting Nuts
RSA Lighting
Visit our web site at: www.rsalighting.com
7945 Orion Avenue, Van Nuys, CA 91406 818-349-3030/ 800-356-3030 FAX 818-349-3031
INSTALLATION INSTRUCTIONS
STEALTH GRAZE
V90181
V90181
FIXTURE MOUNTING
Avoid Fire or Electric Shock
*Installation Instructions for qualified electricians only.
*Install per National Electrical Code and local regulations.
*Read Installation Instructions completely before installation.
*Failure to follow Installation Instructions may void warranties.
FIXTURE MOUNTING (Cont'd)
FIXTURE MOUNTING (Cont'd)
5. Once the fixture is mounted, the Thermal Protector can be returned
5. Once the fixture is mounted, the Thermal Protector can be returned
to proper position by placing the Thermal Bracket back into the
to proper position by placing the Thermal Bracket back into the
Housing using the Thumb Screw. (Figure 6)
Housing using the Thumb Screw. (Figure 6)
U
L
R
C
6. The Fixture can now be mudded with the ceiling material. Apply
drywall tape to inside of the fixture to ensure fixture is not mudded.
Place mudding compound on edge of Plaster Frame and feather
away from fixture on all three sides. (Figure 6) Once the ceiling is
dry, the Trim can now be inserted into the Housing.
Housing
Thumb Screw
Thermal Protector
US
Blocking
Ceiling
Blocking
Mounting Screws
Ceiling
Mounting Screw
Plaster Frame
Mudding Material
FIGURE 5
Trim
FIGURE 6
RSA Lighting
Visit our web site at: www.rsalighting.com