Electronic
- Dual Voltage Input
120/277 VAC, 60 Hz
- Line-latching
- Solid-state Voltage
Limited Charger
- Solid-state Switching
- Brownout Circuit
- Low-Voltage Disconnect
- Overload/Short Circuit
Protection
- Sealed Test Switch/Power
Indicator Light
Housing Construction
- NEMA 4X corrosion
resistant fiberglass
housing
- Industrial grey color
- Vented enclosure
Housing Construction Cont.
- Tough, high contrast
polycarbonate lens
- Rubber booted momentary
test switch and gasketed
charge indicator lamp
- Surface mount only
- Fully gasketed housing
- Wet Location Listed for
operation in ambient
temperatures above
32 degrees F.
Battery
- 6 Volt Sealed Lead Calcium
or Sealed Nickel Cadmium
- Maintenance-Free, Long-Life
- Full Recharge Time
24 hrs. (max.)
Code Compliance
- UL 924 Wet Location Listed
- Life Safety NFPA 101
- NEC/OSHA
- Most State and Local Codes
Warranty
- Exit: 1-year
- Battery: 5-year pro-rata
(Lead Calcium); 15-year
pro-rata (Nickel Cadmium)
Lamp Data
- AC: Two F6T5 fluorescent lamps
- DC: Two 6V, 6W DC lamps
- Long-life, low energy
consumption
- Available with emergency
lighting heads mounted on
enclosure - consult Cooper
Lighting Representative
UMX
SERIES
WET LOCATION EXITS
SELF-POWERED
EMERGENCY FLUORESCENT
LAMPS
Exit Lighting
11 3/4" [298mm]
7 1/2" [191mm]
11 3/4"
[298mm]
E N E R G Y D AT A
Charge Mode (Fully Discharged Battery)
Sealed Lead Calcium Battery
Fluorescent Exits - 6W Lamps
Input Power:
120V= 41W
277V= 43W
Input Current (Max.):
120V= .51A
277V= .22A
Power Factor:
120V= >.66
277V= >.69
T.H.D.:
120V= <14%
277V= <14%
Standby Mode (Fully Charged Battery)
Sealed Lead Calcium Battery
Input Power consumption is reduced by
approximately 18 Watts in the standby
operating mode.
Sealed Nickel Cadmium Battery
Fluorescent Exits - 6W Lamps
Input Power:
120V= 29W
277V= 29W
Input Current (Max.):
120V= .42A
277V= .17A
Power Factor
120V= >.57
277V= >.62
T.H.D.:
120V= <9%
277V= <38%
Sample Number: UMX203
Options
DH
Dual Heads=
Accessories
Protective Housing
WG7
Wire Guard
=
VS2
Polycarbonate Vandal Shield
=
VS2WP
Polycarbonate Vandal Shield ­Weather Proof
=
Letter Color / Arrow Direction
8
Red Letters / Right Arrow=
7
Red Letters / No Arrow=
6
Red Letters / Left Arrow=
5
Red Letters / Double Arrow=
4
Green Letters / Right Arrow=
3
Green Letters / No Arrow=
2
Green Letters / Left Arrow=
1
Green Letters / Double Arrow
=
Series
UMX
Self-Powered Wet Location with Fluorescent Lamps
=
Battery
20
Self-Powered, Lead Calcium
=
22
Self-Powered, Nickel Cadmium
=
10
Lead Calcium Battery w/Remote Capability
=
COOPER LIGH T I N G - SURE-LI T E S
®
Specifications and Dimensions subject to change without notice.
WATTAGE RATINGS
TECHNICAL DATA
UMX EXITS
UMX201 – UMX208 Lead Calcium=18W for 1 1/2 hrs.; 15W for 2 hrs. UMX101 – UMX108 Lead Calcium=27W for 1 1/2 hrs.; 24W for 2 hrs. UMX221 – UMX228 Nickel Cadmium=15W for 1 1/2 hrs.; 12W for 2 hrs.
L a mps
Two F6T5 fluorescent lamps provide long life and normal mode illumination of the lens. Two 6V, 6W DC lamps illuminate the face panel in the emergency mode.
H o usi n g C o n s tru c t i on
The Sure-Lites UMX Series incorporates a rugged enclosure of moisture and corrosion resistant industrial grey fiberglass with a durable polycarbonate lens. Housing is fully gasketed. A breather vent permits ventilation of internal pressure from gases released by charging batteries. UMX Series Exits are suitable for surface mounting onl y. Wet Location Listed for operation in ambient temperatures above 32°F. Optional Thermal Heater available to facilitate use in unheated areas where battery performance would be diminished due to low temperature operation.
L i ne- L a t c h e d
Sure Lites’ line-latched electronic circuitry makes installation easy and economical. A labor efficient AC activated load switch prevents the lamps from turnin g on during installation to a non-energized AC circuit. Line-latching eliminates the need for a contractor’s return to a job site to connect the batteries when the building’s main power is turned on .
S o lid - S t a t e Cha r g e r
Supplied with a 120/277 VAC, voltage regulated solid-state charger. Immediately upon restoration of AC current after a power failure, the charger provides a high charge rate. The charge circuit reacts to the condition of the battery and alters the rate of charge in order to maintain peak battery capacity and maximize battery life. Solid-state construction recharges the battery following a power failure in accordance with UL 924.
O v erl o a d a n d Sh o r t C i rcu i t P r o t ect i o n
The solid-state overload monitoring device in the DC circuit disconnects the lamp load from the battery should excessive wattage demands be made and automatically resets when the overload or short circuit is removed. This overload current protective feature eliminates the need for fuses or circuit breakers for the DC load.
B r own o u t C i r cui t
The brownout circuit on Sure­Lites’ exits monitors the flow of AC current to the exit and activates the emergency lighting system when a predetermined reduction of AC power occurs. This dip in voltage will cause most ballasted fixtures to extinguish causing loss of normal lighting even though a total power failure has not occurred.
S o lid - S t a t e Tr a nsfe r
The UMX Exit incorporates solid-state switching which eliminates corroded and pitted contacts or mechanical failures associated with relays. The switching circuit is designed to detect a loss of AC voltage and automatically energizes the lamps. Upon restoration of AC power, the emergency lamps will switch off and the charger will automatically recharge the battery.
Te s t S wit c h / P o w er I n d i c a t or L i ght
Conveniently located rubber booted Test Switch allows for manual verification of proper operation of the transfer circuit and emergency lamps. A sealed light emitting diode (Power Indicator Light) provides visual assurance that the AC power is on.
S e ale d L e a d Cal c i u m B att e ry
The fully sealed, long-life, maintenance-free, lead calcium battery is ideal for emergency lighting applications. These batteries typically provide 8 to 10 years of life and may be operated in any position.
S e ale d N i c k e l C a dmi u m B a t ter y
Sure-Lites’ sealed nickel cadmium batteries are maintenance-free with a life expectancy of 15 years. The sealed rechargeable nickel cadmium battery offers high discharge rates and stable performance over a wide range of temperatures. The specially designed resealable vent automatically controls cell pressure, assuring safety and reliability. This battery is best suited for harsh ambient temperatures because the electrolyte is not active in the electrochemical process.
W arr a n t y
All Sure-Lites’ products are backed by a firm one-year warranty against defets in material and workmanship (excluding lamps). Maintenance­free, long-life, sealed lead calcium batteries carry a five-year, pro-rata warrant y. Maintenance-free, long-life, sealed nickel cadmium batteries carry a fifteen-year pro-rata warranty.
Sure-Lites • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
10/02/2008 9:07:48 AM
ADX041112
Loading...