Vault
These installation instructions are valid with the above Ametrix styles.
C-Scroll
Roundel
Installation Instructions
Sheet 1 of 3
Large, INDOOR
P1R
(Pendant, 1-way, Remote ballast)
Visor and Non-Visor
Warning
that all sources of power are turned off. All
work must meet local/national codes and be
performed by a certified electrician.
mount fixtures vertically.
: Before starting any work ensure
Do not
Exploded view and part call-out
Mounting plate
Wire ways
Canopy
#10-32
End screw
(2x)
Appropriate fasteners
(by others)
(2x)
#10-32 x3/8"
Pan head screw
(2x)
1/4-20 x3/4"
Hex cap screw
(2x)
Attention:
Large fixtures require additional bracing/structure
around J-box to support fixture..
2
J-box
(by others)
Appropriate
fasteners
(by others)
(4x)
Canopy
Mounting and wiring fixture Aiming the fixture
Use additional bracing
around J-box to support
fixture.
#6-32 x 3/8"
Pan head screws
(2x)
1
Wire connector
#6-32 x 1/4"
Flat head screw
End cap
End screw
(2x)
1. Begin by removing end screw, #6-32 x 1/4" Flat head screw
and end cap from one side of Yoke and remove fixture head.
2. Mount yoke to pendant with both 1/4-20 Hex cap screws.
3. Feed fixture wire through connector in pendant up through
mounting plate and reattach fixture head to yoke.
Securing fixture to pendant
Mounting plate
Yoke
Fixture wire
1/4-20 x 3/4"
Hex cap screw
(2x)
3
#10-32
End Screw
1. Loosen #6-32x 3/8" Pan head screws and allow canopy to slide
down pendant.
2. Feed wires from J-box through wire ways in mounting plate
and secure fixture to bracing around J-box.
3. Attach appropriate wires and ensure all connections are
properly matched.
4. Replace canopy and secure with both #6-32 x3/8" Pan head
screws.
ADY071470 REV A(ECN070347)
Yoke arm
indicator
1. To aim fixtures, loosen both #10-32 end screws on
fixture. When both indicators are lined up, the slope of the
lens face is 40-degrees. Each subsequent notch is an
additional +/- 10-degrees.
2. When fixture head is rotated to the desired angle, retighten
end screws to secure the position.
Fixture head
indicator
Vault w/ visor
These installation instructions are valid with the above Ametrix styles
C-Scroll w/ visor
Mounting Plate Dimensions In[mm]
1
1
2
38.10
1
"
3
5"
127
2
88.90
Roundel w/ visor
"
3
"
4
19.05
Installation Instructions
Sheet 2 of 3
Large, INDOOR
P1R
(Pendant, 1-way, Remote ballast)
Visor and Non-Visor
Warning
that all sources of power are turned off. All
work must meet local/national codes and be
performed by a certified electrician.
mount fixtures vertically.
3
4
19.05
: Before starting any work ensure
Do not
"
Top View
1
"
2
12.70
1
3
"
2
88.90
5"
127
Length dependant
on order
9
32
7.11
"
Side View
ADY071470 REV A(ECN070347)