Cooper Lighting Power Failure Emergecny Light ENC User Manual

INVUE
15 25/32" [400 mm]
7 3/4"
[196 mm]
8 1/8" [206 mm]
IP66 Rated U.L. 1598
Full Cutoff
FCO
CSA Listed 40°C Ambient ISO 9001
Certifications
NOTE: 250W Quartz requires thru-way mounting box. 150W requires magnetic ballast.
TM
WALL MOUNT
ENC
ENTRI ROUND CLEAN
26-250W
Metal Halide
WhiteSON High Pressure
Sodium
Compact Fluorescent
Quartz Halogen
ARCHITECTURAL WALL
LUMINAIRE
• One piece die-cast aluminum construction. Accommodates either up or down mounting configurations with no modifications
• One piece die-cast aluminum faceplate utilizes a continuous silicone gasket to seal securely to housing
• Side hinged faceplate swings open via release of one (1) flush mount die-cast aluminum latch on housing side panel
• Choice of ten (10) high efficiency optical systems
• Ballast and related electrical componentry are heat sunk to the housing
• Optional die-cast aluminum adapter box to allow for surface conduit wiring, quartz lamp options, and emergency battery pack capability
DESCRIPTION
DIMENSIONS
ENTRI Series’ family of modular faceplate designs provide a tasteful architectural statement equally suitable for indoor and outdoor environments. Available luminous faceplate window adds a signature look, while affording custom color capability.
In downlight only configurations with no faceplate window.
ORDERING INFORMATION
SAMPLE NUMBER: ENC-150-MH-120-EB-3S-BK-LG-L
1
Lamp Type MH=Metal Halide WS=White SON
CF=Compact
2
HL=Quartz
3
4
3
3
5
Product Family ENC=ENTRI
Round Clean
Optional Luminous Faceplate Insert LG=Luminous Glass Insert LGO=Luminous Glass Insert
with Warm Orange Gel
LGR=Luminous Glass Insert
with Red Gel
LGB=Luminous Glass Insert
with Bright Blue Gel
LGG=Luminous Glass Insert
with Deep Green Gel
Lamp Wattage HID 39=39W 70=70W 100=100W 150=150W Compact Fluorescent 26=26W 32=32W 42=42W 52=52W 57=57W 64=64W 84=84W Halogen 100=100W 150=150W 250=250W
High Pressure Sodium
Fluorescent
Halogen
14
Options F=Single Fuse (120, 277 or 347V)
FF=Double Fuse (208, 240 or 480V)
DSAB=Dual Fluorescent Switching
QAB=Quartz Restrike Adapter Box EMAB=Quartz Restrike with Delay Adapter Box
EM/SCAB=Quartz Emergency Separate Circuit
CF/EMAB=Emergency Battery Backup Adapter Box
PC=Button Type Photocontrol
WG=Wire Guard FRM=Frosted Main Flat Glass FRS=Frosted Secondary Flat Glass L=Lamp Included
Voltage 120=120V 208=208V 240=240V 277=277V
6
347=347V 480=480V
7
DT=Dual-Tap
Wired 277V
MT=Multi-Tap
Wired 277V
TT=Triple-Tap
Wired 347V
UNV=120-277V
14
Specify Voltage
Specify Voltage
Control Adapter Box
(Also Strikes at Cold Start)
Adapter Box
(Specify 120 or 277V)
(specify voltage)
(Standard for all Halogen lamps)
17
8
Universal Electronic Ballast
Ballast MB=Magnetic EB=Electronic
Ballast
X=None
(for Halogen Lamp)
9
10
11
15
16
18
Optical System Downlight or Uplight (HID or
12
Halogen) 3S=Type III FT=Forward
Throw
FX=Wall Grazing
Optic
TS=Tight Spot Downlight and Uplight (HID and Halogen) 3SG=Type III, 90% Main/10% Secondary
Glow
3SP=Type III with Pencil Secondary FTG=Forward Throw, 90% Main/
10% Secondary Glow
FTP=Forward Throw with Pencil Secondary FXF=Wall Grazing Optic, 50% up/50% Down TSF=Tight Spot, 50% up/50% Down Compact Fluorescent CFG=90% Main + 10% Secondary Glow CFM=100% Main, Up or Downlighting
Accessories VA2001-XX=Thru-way Box VA2002-XX=Wire Guard Kit
19
ENC
WATTAGE TABLE
Metal Halide 39, 70, 100, 150W
White Son HPS 100W
Compact Fluorescent 26, 32, 42, 57W
Dual Compact Fluorescent (2) 26, (2) 32, (2) 42W
Quartz Halogen 100, 150, 250W
Colors (add as suffix/must specify)
BK=Black AP=Grey BZ=Bronze WH=White DP=Dark Platinum GM=Graphite Metallic
Options &
13
Accessories
(See Below)
• Approximate net weight: 13 lbs. (6 kgs.)
1120
COOPER LIGHTING
NOTES: 1 All MH lamps are T6 envelope with G12 lamp base. All HPS lamps are T6 envelope with GX12 lamp base. 2 All 26/32/42/57W CF lamps feature a 4-pin lamp
base. Available in CFM and CFG distributions only. 3 Dual compact fluorescent lamps. 4 Nominal M.O.L lamp length of 57W CFL not to exceed 7". 5 All Halogen lamps are T4 envelope with mini-can base, 120V lamp. 6 WhiteSON HPS lamp available in 100W only. Requires electronic ballast. 120/277V only. Includes use of VA2001 accessory Thru-way Box. 7 Compact Fluorescent ballasts contain internal fusing. No supplemental fusing is necessary. CF ballasts are 120 through 277V. Specify with UNV voltage designation. 8 Products also available in non-US voltages and 50Hz for international markets. Consult factory for availability and ordering information. 9 Dual-tap is 120/277V wired 277V. 10 Multi-tap is 120/208/240/277V wired 277V. 11 Triple-tap is 120/277/347V wired 347V. 12 120 through 277V only. Electronic ballasts contain internal fusing, no supplemental fusing is necessary. Electronic ballast available with all CF lamps, and 39/70/100W MH lamps. Available with 150W MH lamp. Includes VA2001 accessory Thru-way Box. Not available with QAB or EMAB options. 13 Custom and RAL color matching available upon request. Consult your INVUE Lighting Systems Representative for further information. 14 Add as suffix in the order shown. 15 Dual switching requires dual 26, 32 or 42W Compact Fluorescent lamps. Allows independent switching control of each lamp through use of two (2) electronic ballasts. Allows 50% power reduction when dual ballasts are independently wired and controlled. 16 CF lamps only. Battery backup operates 90 minutes at minimum 32°F (0°C), 42W maximum. 17 For use in down lighting applications only. 18 Frosted secondary lens provided standard on 3SG, FTG, and CFG distributions. 19 Order separately, replace XX with color suffix. 20 Specifications and dimensions subject to change without notice.
Loading...