Cooper Lighting Portfolio HD7500QT4, Portfolio HD7250QT4 Installation Instructions Manual

Page 1
PORTFOLIO
A
y
A
y
®
Installation Instructions for HD7500QT4 and HD7250QT4 Commercial Recessed Housing
Top Accessory Cover
Housing
Heat Sink and Lamp Assembly
Junction Box
Upper Reflector
ssembl
Hanger Bracket
Plaster Frame
CAUTION: To avoid possible electrical shock, be sure that power supply is turned
off before installing or servicing this fixture.
Note: This fixture should be supported by main runners or other structure that
Step 1 To Install Fixture: Using standard bar hangers, C-Channels (available
through Portfolio or furnished by others), ¾” and 1-1/2” lathing or ½” conduit (all supplied by others), insert thought the universal hanger brackets and secure the mounting bars or channels to the ceiling structure so that the edge of the die cast mounting frame is flush with the finished ceiling.
Junction Box Cover
Lower Reflector
ssembl
Step 2 To Install Upper Reflector: Cut plastic tie wrap securing heat sink to
bracket. Install quartz mini-can frosted lamp. WARNING: DO NOT
handle quartz lamps with bare hands. Grease from fingerprints may cause premature end of life or shattering of lamp. Install heat
sink to upper reflector assembly carefully guiding lamp into reflector opening (Fig 1). Rotate heat sink until flanges are seated under retention springs. Insert completed assembly through housing opening and into moveable bracket until seated securely (Fig 2).
Step 3 To Install Lower Trim: Attach trim safety tether to mounting bracket via
clip. Trim is held in place with torsion springs that pass through slots in mounting bracket.
1
FIG 1
Page 2
PORTFOLIO
®
Installation Instructions for HD7500QT4 and HD7250QT4 Commercial Recessed Housing
Step 4 To Clean Trim: First, gently wipe with a soft, clean, dry lint-free cloth to
remove loose dust. Then, use mild detergent solution on a soft cloth to remove finger prints and stains. Rinse with clean, soft water and dry with lint-free cloth.
Step 5 Relamping: Allow sufficient time for the lamp to cool. Relamping may
be performed from above or below the fixture. To relamp from below the fixture: Remove lower trim and then remove upper reflector by pressing the four retention springs inward (Fig 3). Rotate heat sink to clear retention springs and carefully separate from reflector assembly. Replace lamp and reassemble as described in steps 1-4. To relamp from above the fixture (Fig 4): Remove the top access cover. Rotate heat sink to clear retention springs and carefully separate from reflector assembly. Replace lamp and reassemble.
FIG 2
FIG 3
FIG 4
2