CATALOG#: TYPE:
Specification grade wet listed 32 or 26 Watt triple tube compact fluorescent fixture rated for use in wet locations. Regressed frosted lens provides a low brightness aperture and a smooth illumination pattern. Triple tube lamps provide excellent color
and long life. Dimming and emergency ballast options are available. Lamp module and optical
A
...
Reflector
.040 thick aluminum specular clear upper and spun parabolic lower reflector in Clear, Gold, Haze, Warm Haze, Black Alzak®finish,
painted gloss
white or matte white
. Special cone colors listed
below.
B
...
Flange
Self flange reflector or die cast flange with either matte white or clear coat finish. Die cast flanges are easily removed for field painting. Elements are keyed for proper insertion. Gasket is a closed cell foam.
C
...
Lens
.125 thick frosted lens obscures lamp and is retained during relamping.
D
...
Attachment
Positive torsion springs pull flange tight to ceiling. Mechanical light trap eliminates spill light at edge of flange or reflector.
E
...
Socket
4 pin G24q3 base for 32 or 26W PLT, TBX and TTT lamps. Fatigue free stainless steel spring ensures positive lamp retention. Fixed socket height ensures consistent lamp position.
F
...
Electronic Ballast
Thermally protected, current controlled electronic ballast produces full light output and rated lamp life. Meets stringent FCC part 18 Class B requirements.
G
...
Electrical
Keyed quick connect provides easy lamp module installation.
H
...
Frame/Housing
Hot dipped galvanized 20 gauge steel frame with built in 1/2 inch plaster lip Aluminum .032 thick housing allows for heat dissipation and reduces weight.
I
...
Junction Box
18 cubic inches, listed for 4#12 AWG or 6#14 AWG 90° C additional feed through conductors, has five 1/2 inch pryouts.
J
...
Bar Hangers
No Flex®bar hangers with positive locking, for use with joists spaced up to 24" O.C. ship with plat­form. For use in T-bar ceilings order accessory MBCLP. Nailess barb and locator lip provide con­sistent installation height.
K
...
Codes
Thermally protected, IP labeled. Unit is airtight and exchanges less than 2.0 CFM with the plenum at apressure of 75 pascals. Insulation must be kept three inches away from fixture sides and none on top as to entrap heat.
L
...
Labels
UL and cUL listed, standard wet label, IBEW union made.
ADI030825
SPECIFICATION FEATURES
I
B
A
E
G
F
J
H
D
C
M32T= 32/26W Compact Flourescent Ballast
M32T Lutron = 32W only
Tu Wire Dimming Ballast
ORDERING INFORMATION
Complete unit consists of a platform, module and element
PN5
PN5 = 5" Airtight Non-IC Rated Housing
Lamp
Module
E5SR = 5" Regressed Lens Showerlight
Optical
Element
Platform
COOPER LIGHTING
PN5
M32T
E5SR
32W TRIPLE
Compact Fluorescent
5" REGRESSED LENS
SHOWERLIGHT
5
1/ 4
"
ENERGY DATA 5" AirTight
Input Power: 120V = 36W Input Current (Max.): 120V = .306 Power Factor: 120V = .98 T.H.D.: 120V = <10%
M32T LUTRON
Input Power: 120V = 36W Input Current (Max.): 120V = .33A Power Factor: 120V = >.95 T.H.D.: 120V = <20%
DESCRIPTION
5 1/4"
[134mm]
6 1/4"
[159mm]
6 3/4"
[172mm]
Accessories
MBCLP = 40 Push On T Bar Clips (for 10 Units)
PLE5 = Plaster Lip Extension for Max 2" Thick Ceiling
Blank= Matte White die-cast
SF= Self Flange RAW= Natural
Die-cast SFWF= Self
Flange Painted White
Flange
Finish
Standard
C = Clear H = Haze G = Gold WMH = Warm Haze W = Gloss White MW= Matte White B= Black
Custom
K = Cognac KH = Cognac Haze
Custom
CC = Chocolate CCH = Chocolate Haze BU = Blush BUH = Blush Haze GP = Graphite GPH = Graphite Haze PN = Pine PNH = Pine Haze SK = Sky SKH = Sky Haze
8 1/2"
[216mm]
8 1/2"
[216mm]
4 15/16" [126mm]
16 1/2"
[419mm]
Ceiling Cutout
6 1/4" [159mm]
For additional options please consult factory. Matte white is recommended for self flanged reflectors
PHOTOMETRICS
P5-M32T-E5SRC
Test No. H36117 Lamp: 26W PLT
Lumens: 1800 Cutoff: 75°
Spacing: 1.1 Efficiency: 32.4% Unit LPW: 22.43
Unit Number: PN5-M32T-E5SRC
Candelas
Vertical CD Angle
90 0 85 0 75 5 65 37 55 82 45 142 35 202 25 256 15 294
5 309 0 311
Luminance
Degree cd/m
2
85
˚
0
75
˚
1410
65
˚
6266
55
˚
10183
45
˚
14384
4'6" 5'6" 6'6" 8'0" 10'0" 12'0"
5'0" 6'6" 7'6"
9'6" 11'6" 14'0"
15 10
7 5 3 2
Cone of Light
Distance to Initial Nadir Beam Illuminated Plane Footcandles Diameter
Notes and Formulas:
Luminance: To convert cd/m
2
to footlamberts, multiply by 0.2919
Cone of Light:
• Footcandle and CU multiplier: clear x 1.0, Haze x .95, Gold x .90, Black x .65, Warm Haze x .90
• Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
• Footcandle values are initial. Apply appropriate light loss factors where necessary.
CU Notes/Formulas:
• maintained illuminance=lamp lumens x CU x light loss factors room area
• total number of luminaires=total room area x maintained illuminance
lamp lumens x CU x light loss factors
• CU data based on 20% effective floor cavity reflectance.
80% 70% 50% 30% 0%
70 50 30 10 50 10 50 10 50 10 0
38 38 38 38 38 38 36 36 34 34 32 36 35 34 33 34 33 33 32 32 31 29 34 32 31 29 32 29 30 28 29 28 26 32 29 27 26 32 29 30 28 29 28 26 30 27 25 23 26 23 26 22 25 22 21 28 24 22 20 24 20 23 20 23 20 19 26 22 20 18 22 18 21 18 21 18 17 24 20 18 16 20 16 19 16 19 16 15 22 18 16 14 18 14 18 14 17 14 14 21 17 15 13 17 13 16 13 16 13 12 19 16 13 12 15 12 15 12 15 12 11
Ceiling Reflectance
Wall Reflectance
Room Cavity Ratio
0 1 2 3 4 5 6 7 8 9
10
Coefficient of UtilizationZonal Lumen Summary
Zone Lumens %Lamp %Luminaire
0-30 230 12.8 39.5 0-40 356 19.8 61.1 0-60 539 30.0 92.6 0-90 582 32.4 100.0 90-180 0 0.0 0.0 0-180 582 32.4 100.0