Cooper Lighting P5 M120 E5SR User Manual

CATALOG#: TYPE:
Specification grade wet listed A lamp fixture rated for direct contact with insulation. Regressed frost­ed lens provides a low brightness aperture and a smooth illumination pattern. Lamp module and
optical element can be changed after installation to provide a variety of lamp sources and distribu­tions. e.g. into a PAR36 Adjustable
...
Reflector
.040 thick aluminum specular clear upper and spun parabolic lower reflector in Clear, Gold, Haze, Warm Haze, Black Alzak
®
finish,
painted gloss
white or matte white
. Special cone colors listed
below.
B
...
Flange
Self flange reflector or die cast flange with either matte white or clear coat finish. Die cast flanges are easily removed for field painting. Elements are keyed for proper insertion. Gasket is a closed cell foam.
C
...
Lens
.125 thick frosted lens obscures lamp and is retained during relamping.
...
Attachment
Positive torsion springs pull flange tight to ceiling. Mechanical light trap eliminates spill light at edge of flange or reflector.
E
...
Socket
Nickel plated porcelain socket. Fixed socket height ensures consistent lamp position.
F
...
Electrical
Keyed quick connect provides easy lamp module installation.
...
Frame/Housing
Hot dipped galvanized 20 gauge steel frame with built in 1/2 inch plaster lip Aluminum .032 thick housing allows for heat dissipation and reduces weight.
H
...
Junction Box
18 cubic inches, listed for 4#12 AWG or 6#14 AWG 90° C additional feed through conductors, has six 1/2 inch pryouts.
I
...
Bar Hangers
No Flex®bar hangers with positive locking, for use with joists spaced up to 24" O.C. ship with plat­form. For use in T-bar ceilings order accessory MBCLP. Nailess barb and locator lip provide con­sistent installation height.
J
...
Codes
Thermally protected, IP labeled, for use in direct contact with insulation. Meets Washington State Air tight requirements, 1995 CABO Model Energy Code.
K
...
Labels
UL and cUL listed, standard wet label, IBEW union made.
ADI030813
SPECIFICATION FEATURES
H
B
E
F
I
C
ORDERING INFORMATION
Complete unit consists of a platform, module and element
COOPER LIGHTING
P5
M120
E5SR
75W A19
75W BT15
60W MB19
5" REGRESSED LENS
SHOWERLIGHT
5
1/ 4
"
DESCRIPTION
5 1/4"
[134mm]
6 1/4"
[159mm]
6 3/4"
[172mm]
9"
[229mm]
10"
[254mm]
7 7/8"
[201mm]
15 3/4"
[401mm]
P5
P5 = 5" Airtight IC Rated Housing
Platform
Accessories
MBCLP = 40 Push On T Bar Clips (for 10 Units)
PLE5 = Plaster Lip Extension for Max 2" Thick Ceiling
E5SR
Optical
Element
E5SR = 5" Regressed Lensed Showerlight
M120
M120 = 120V Medium Base Socket
Lamp
Module
Blank= Matte White die-cast
SF= Self Flange RAW= Natural
Die-cast SFWF= Self
Flange Painted White
Flange
Finish
Standard
C=Clear H=Haze G=Gold WMH=Warm Haze W=Gloss White MW= Matte White B= Black
Custom
K=Cognac KH=Cognac Haze CC=Chocolate
Custom Cont.
CCH=Chocolate Haze
BU=Blush BUH=Blush Haze GP=Graphite GPH=Graphite
Haze PN=Pine PNH=Pine Haze SK=Sky SKH=Sky Haze
Ceiling Cutout
6 1/4" [159mm]
For additional options please consult factory. Matte white is recommended for self flanged reflectors
PHOTOMETRICS
P5-M120-E5SRC
Test No. H36116 Lamp: 75A19/IF
Lumens: 885 Cutoff: 75°
Spacing: 1.0 Efficiency: 32.8% Unit LPW: 3.8
Unit Number: P5-M120-E5SR_
Candelas
Vertical CD Angle
90 0 85 0 75 3 65 18 55 39 45 68 35 99 25 129 15 156
5 174 0 176
Luminance
Degree cd/m
2
85
˚
0
75
˚
774
65
˚
3065
55
˚
4817
45
˚
6914
4'6" 5'6" 6'6" 8'0" 10'0" 12'0"
4'6" 5'6" 6'6"
8'0" 10'0" 12'0"
9 6 4 3 2 1
Cone of Light
Distance to Initial Nadir Beam Illuminated Plane Footcandles Diameter
Notes and Formulas:
Luminance: To convert cd/m
2
to footlamberts, multiply by 0.2919
Cone of Light:
• Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
• Footcandle values are initial. Apply appropriate light loss factors where necessary. See Iris catalog for further discussion.
CU Notes/Formulas:
• maintained illuminance=lamp lumens x CU x light loss factors room area
• total number of luminaires=total room area x maintained illuminance
lamp lumens x CU x light loss factors
• CU data based on 20% effective floor cavity reflectance.
80% 70% 50% 30% 0%
70 50 30 10 50 10 50 10 50 10 0
39 39 39 39 38 38 36 36 35 35 33 37 36 35 34 35 33 34 32 32 31 30 35 33 31 30 32 29 31 29 30 28 27 32 30 28 26 29 26 28 26 28 25 24 30 27 25 23 27 23 26 23 25 23 22 28 25 23 21 25 21 24 21 23 20 20 26 23 20 19 22 19 22 18 21 18 18 24 21 18 17 20 17 20 16 20 16 16 23 19 17 15 19 15 18 15 18 15 14 21 17 15 14 17 13 17 13 17 13 13 20 16 14 12 16 12 16 12 15 12 12
Ceiling Reflectance
Wall Reflectance
Room Cavity Ratio
0 1 2 3 4 5 6 7 8 9
10
Coefficient of UtilizationZonal Lumen Summary
Zone Lumens %Lamp %Luminaire
0-30 120 13.5 41.2 0-40 182 20.5 62.5 0-60 269 30.4 92.7 0-90 290 32.8 100.0 90-180 0 0.0 0.0 0-180 290 32.8 100.0
Distribution
Note: Specifications and Dimensions subject to change without notice.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801 ADI030813
Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1B8 905.507.4000 FAX 905.568.7049
Loading...