SPECIFICATION FEATURES
09/17/2008 2:35:44 PM
Consult your representative for additional options and finishes.
Specifications and Dimensions subject to change without notice.
ADF020747
LAMP CONFIGURATIONS
MOUNTING DATA
DESCRIPTION
The DIVM Series is an energy efficient family of industrials that feature
premium performance and durability. The industrial series incorporates
heavy duty, embossed, reflectors that precisely direct and effectively control
light. The special deep center "V" reflector provides 30° crosswise shielding
to minimize glare. The versatile DIVM Series can be installed using various
mounting methods and numerous options and accessories are available.
The DIVM Series can be utilized in simple task and area lighting to the most
demanding industrial applications.
A ... Construction
Channel is code gauge prime cold
rolled steel. Die formed with deep
V-grooves for tong hanger. Die
formed channel connector assures
straight rows and continuity of
ground through set screws.
Lampholder mounting brackets are
easily inserted with snap-in action.
B ... Electrical*
Ballast are CBM/ETL Class "P" and
positively secured by mounting
bolts. Metal clad lampholders are
spring loaded for turret safety.
UL/CUL listed. Suitable for damp
locations.
C ... Finish
Multistage iron phosphate
pretreatment ensures maximum
bonding and rust inhibitor.
Lighting grade, baked white
enamel finish.
D ... Reflectors
Painted after fabrication. Die
formed code gauge steel. Deep
draw full width ribs formed with
one press stroke. Side flanges lend
strength with upward turn. Easily
cleaned. Baked white enamel
13-1/2" width. Four foot sections.
Reflector Center "V" provides 30°
crosswise shielding and reduces
glare. Reflector and Center "V"
retained by positive mounting bolt.
Reflector aligners provided.
Standard with 20% uplight (DIVM)
Closed top reflector (DCIVM).
DIVM
248PG
296PG 248VHO 296VHO
4' OR 8' INDUSTRIAL
2 LAMP
POWER GROOVE, 1500MA
VERY HIGH OUTPUT,
1500MA
Heavy Duty Industrial
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power
6-1/8"
[156mm]
13-1/2"
[343mm]
A B C
D
13-1/2"
[343mm]
6-1/8"
[156mm]
6"
[152mm]
X=4-1/4" [108mm]
X
Ground Screw Bump
7/8" [22mm] K.O. (3)
11/16" [17mm] x 1 K.O. (2)
7/32" [6mm] x 3/8" [10mm] K.O. (4)
4-1/4"
[108mm]
5/16"
[8mm]
1-1/16"
[27mm]
41-1/2" [1054mm]
37-1/4" [946mm]
48" [1219mm]
4-1/4"
[108mm]
5/16"
[8mm]
7/8" [22mm] K.O. (5)
11/16" [17mm] x 1 K.O. (2)
7/32" [6mm] x 3/8" [10mm] K.O. (4)
Ground Screw Bump
1-1/16"
[27mm]
89-1/2" [2273mm]
85-1/4" [2165mm]
96" [2438mm]
76" [1930mm]
STD Ballast & STD Lamps
248PG (242) 296PG (440) 248VHO (242) 296VHO (440)
Luminaire Efficacy Rating
LER = FI-59 Catalog Number: DIVM-296PG
Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.07
*Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements.
E N ER G Y D AT A
Input Watts:
COOPER LIGHTIN G - ME TA LU X
®
Specifications and Dimensions subject to change without notice.
PHOTOMETRICS
ORDERING INFORMATION
ACCESSORIES
SHIPPING INFORMATION
DIVM
C a n de la
Angle Along II 45
o
Across
0 10 20 30 40 50 60 70 80 90
100 110 120 130 140 150 160 170 180
7110 7110 7110 7021 6991 7081 6689 6693 6748 6168 6164 6219 5469 5460 5545 4573 4551 4104 3532 3084 2363 2321 1382 947
998 448 444
24 100 131 257 226 217 672 417 417
1093 684 634 1478 1016 899 1800 1298 1218 2064 1613 1466 2243 2149 1892 2351 2339 2363 2376 2376 2376
C o e f
f i c ie nt s of Ut il iz at io n
Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0 1 2 3 4 5 6 7 8 9
10
Z o n al L u me n Su mm ar y
Zone Lumens %Lamp %Fixture
0-30 0-40 0-60 0-90 90-180 0-180
||
DIVM-296PG
Standard Ballast
F96PG17/CW Lamps 15300 Lumens
Spacing criterion: (II) 1.3 x mounting height, () 1.3 x mounting height
Efficiency 84.4%
Test Report: DIVM296PG.IES
LER = FI-59
Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.07
5605 18.3 21.7
9275 30.3 35.9 16531 54.0 64.0 20185 66.0 78.2
5627 18.4 21.8 25811 84.4 100.0
96 96 96 96 92 92 92 92 84 84 84 76 76 76 69 69 69 66 88 84 81 78 84 80 77 75 74 71 69 67 65 64 61 60 59 56 80 74 68 64 76 70 66 61 65 61 57 59 56 53 54 52 50 47 73 65 58 53 70 62 56 51 57 52 48 52 48 45 48 45 42 40 67 57 50 45 64 55 49 44 51 45 41 47 42 39 43 39 36 34 61 51 44 39 58 49 42 38 45 40 35 42 37 33 38 35 31 29 57 46 39 34 54 44 38 33 41 35 31 38 33 29 35 31 28 26 52 42 34 29 50 40 33 29 37 31 27 34 29 26 32 28 25 23 49 38 31 26 46 36 30 26 34 28 24 31 27 23 29 25 22 20 45 35 28 23 43 33 27 23 31 26 22 29 24 21 27 23 20 18 43 32 25 21 41 31 25 21 29 23 20 27 22 19 25 21 18 16
Tandem Blank=4' Length 8T=8' Length
Series DIVM=Apertured
Reflector
DCIVM=Closed Top
Reflector
SAMPLE NUMBER: DIVM-296PG-120V -EB81- U
Number of Lamps 2 Lamps
(Not included)
Voltage
(1)
120V=120 Volt 277V=277 Volt 347V=347 Volt
Options GL=Single Element Fuse GM=Double Element Fuse Emergency=EM Installed
NOTES:
(1)
Products also available in non-US voltages and frequencies for internation-
al markets.
Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
Wattage (Length) 48VHO=110W (48") VHO 96VHO=185/215W (96") VHO 96PG=185/215W (96") PG
Ballast Type
(1)
EB8 = T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
EB8
/PLUS=T8 Electronic Instant Start.
High Ballast Factor >1.13. Total Harmonic Distortion < 20%
ER8
=T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
EB2
=T12 Electronic Rapid Start.
No. of Ballast 1, 2 or 3
No. of Ballast 1, 2 or 3
No. of Ballast 1, 2 or 3
No. of Ballast 1 or 2
Options RIF1=Radio Interference
Suppressor 6-3/18 SJT-C&P-515P=Cord & Plug (120V)
6-3/18 SJT-C&P­L715P=Cord & Plug (277V) PI/CPI=Plug-In Option TILW=Tandem In-Line
Wiring Option (Consult TILW Option Catalog Page)
POX=Porlux Finish
(See options & accessories)
Packaging U=Unit Pack 4B=4 Bulk
(Order Separately)
A1B/Spacer-U=Spacer 1-1/2" to 2-1/2" from ceiling (Use 2 per fixtur
e)
ATG-4=Tong Hanger (Use 2 per fixture)
SCF=Fixed Stem Set (Specify Length)
SCS=Swivel Stem Set (Specify Length)
SCA=Adjustable 48" Stem Set
AYC-Chain/Set-U=Chain Hanger Set (Use 1 set per fixture)
WG/DI-4FT-U2=Wire Guard
WGG/DI-4FT-U2=Wire Gym Guard
MECL-DI/SL-48-U=Metal Egg Crate Louver
MECL-DI/SL-96-U=Metal Egg Crate Louver
DI2=Long Connector
CEP=Closed End Plate
(Additional Accessories Available. See Options and Accessories Section).
DIVM-248PG
1
26 lbs.
DIVM-296PG
1
41 lbs.
Catalog No. Wt.
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801