Warning
that all sources of power are turned off. All
work must meet local/national codes and be
performed by a certified electrician.
mount fixtures vertically.
: Before starting any work ensure
Do not
Exploded View and Part Call-Out
Mounting plate
J-box
(by others)
Installation Instructions
Sheet 1 of 3
Roundel, XL
IN/OUTDOOR
P2R
(Pendant, 2-way, Remote)
Visor and Non-Visor
Canopy
1/4-20 x1"
Aiming screw
(x4)
3/8-16 x1"
End screw
(x4)
End cap
1.
Securing Pendant to Structure in Ceiling
Mounting plate
Appropriate fasteners
(by others)
#8-32 x 1/2"
Pan head screws
(x2)
Yoke arms
(x4)
2-way yoke
All extra large fixture require additional bracing/structure around J-box to support fixture.
J-box
(by others)
Attention:
2.
Pendant length dependant
on order
1/4-20 x4"
Hex bolt
(x2)
Fixture door
Aiming screw
spacer
(x4)
Securing Yoke to Pendant
2-way
yoke
1/4-20 x4"
Hex bolts
(x2)
#10-32 x1/2"
Pan head screws
(x2)
Canopy
1.
Loosen both #10-32 x1/2" Pan head screws and allow canopy
to slide down pendant.
2.
Feed power wire from j-box into pendant, ensure wire reaches
electrical cover plate on base of pendant.
3.
Using appropriate fasteners(by others), secure mounting plate
to structure/bracing around J-box.
ADY080868 REV A(ECN080377)
1/4-20 x1"
socket screw
Yoke arms
(x4)
1.
Using all eight 1/4-20 x1" screws, secure yoke arms on both
sides of 2-way yoke.
2.
After securing arms, slide 2-way yoke assembly onto pendant
and secure using both 1/4-20 x 4" hex bolts.
(x8)
Warning
that all sources of power are turned off. All
work must meet local/national codes and be
performed by a certified electrician.
mount fixtures vertically.
: Before starting any work ensure
Do not
Installation Instructions
Sheet 2 of 3
Roundel, XL
IN/OUTDOOR
P2R
(Pendant, 2-way, Remote)
Visor and Non-Visor
3.
Wire connector
1.
While firmly supporting fixture head, use 3/8-16 x1" end screw to secure fixture head to yoke arms.
2.
Slide one aiming screw spacer between fixture head and yoke arm on each side and secure fixture heads angle using 1/4-
20 x1" aiming screws. Repeat for second fixture.
3.
Remove electrical cover plate from pendant tube.
4.
Insert fixture head wire into wire connection at base of pendant tube and run up to electrical cover plate.
5.
Insert wire from second fixture head into opposite wire connector and run wire to electrical cover plate.
6.
Attach appropriate wires ensuring all connections are properly matched and replace electrical cover plate.
4.
Mounting and Wiring Fixture Heads to Pendant
Electrical cover
plate
2nd fixture head
removed for clarity.
Sealing and Aiming the Fixtures
1/4-20 x1"
Aiming screw
(x4)
3/8-16 x1"
End screw
(x4)
End cap
(x4)
Electrical cover
plate gasket
Captive door
screws
(x10)
Fixture door
End cap
(x4)
1.
To aim fixture, unscrew end caps from fixture. Loosen both 1/4-20 x1" aiming screws on both sides of fixture. When
yoke indicator and fixture head indicator are lines up the slope of the fixture head is 40-degrees. Each subsequent notch
is an additional 10-degrees. When fixture is rotated to desired angle, secure with aiming screws.
2.
Secure door using proper torque specifications and sequence as described in supplementary sheet.
3.
Thoroughly check seal on all gaskets and wire connectors to ensure seals are smooth and compressed.
Wire connectors
(x4)
40
Side View
1/4-20 x1"
Aiming screw
(x4)
ADY080868 REV A(ECN080377)