DIMENSIONS
17" [432mm]
MOUNTING
5 1/8"
[130mm]
Once in place, the EZ123 readily accepts the mating half of the hinge and the fixture is easily attached.
P=Mounting Bracket for
Surface Mounting or Mounting to 4" J-Box.
ORDERING INFORMATION
SAMPLE NUMBER: HPBE-5A-100H-MT-LL
Lamp Type HP=High
Pressure Sodium
MH=Metal
Halide
MP=Pulse
Start MH (CWA)
MD=Pulse Start Metal Halide (Electronic)
Series BE=Vertimark II
1
2
Lens Type 2A=Type II 5A=Type V 2P=Type II
Polycarbonate
5P=Type V
Polycarbonate
3, 4
Surface
12 1/2"
[318mm]
Pendant
13 1/4"
[337mm]
2 9/16"
[65mm]
5
5
Lamp Wattage 100=100W 150=150W 175=175W 200=200W 250=250W
Power Factor H=HPF
6
_ =NPF
COOPER LIGHTING - LUMARK
DESCRIPTION
The Vertimark II delivers horizontal and vertical footcandles to evenly illuminate low mounting areas such parking garages or storage facilities areas. The combination die-cast reflector/ ballast housing makes Vertimark II economical. Modular assembly makes installation easy and quality construction ensures years of consistent performance. U.L. listed and labeled for damp location. CSA Certified. Wet location optional.
Powered by
technology
7
Voltage 120V 208V 240V 277V 347V 480V MT=Multi-Tap TT=Triple-Tap E=Electronic
LL=Lamp
4
9
10
Included
4
4
4
8
Options & Accessories
(See Pages 541-545)
VERTIMARK II
100-250W
High Pressure Sodium
Pulse Start Metal Halide
Metal Halide
INDUSTRIAL LUMINAIRE
• Standard quick mounting plate for 3/4" IPS conduit frees both hands to complete wiring
• Die-cast aluminum housing has durable white polyester powder coat finish
11
• Hinged refractor permits relamping without removal of refractor
• Acrylic prismatic refractor controls light for high vertical and horizontal footcandles
BE
LOW-BAY
INDUSTRIAL
®
LAMP MORTALITY AND LUMEN MAINTENANCE COMPARISONS
100
90
80
70
60
50
40
% Lamp Survival
30
20
10
0
2000 4000 6000 10000 8000 12000 14000 16000 18000 20000 22000 24000 26000 28000 30000
0
TM ® ®
Natural White & Uni-Form Pulse Start on ECON TECHNOLOGY Uni-Form Pulse Start on CWA Probe Start Metal Halide on CWA
NOTE: Lamp Mortality and Lumen Maintenance Charts Courtesy of VENTURE
Series Wattage
Vertimark II 100-250W
NOTES: * Electronic Pulse Start Metal Halide. (200-277V). 120V 25°C.
NOTES: 1 150W is maximum wattage available in HPS. 2 Pulse Start Metal Halide available on 100, 150, 175, 200, and 250W only. 3 250W only. 4 MD available in 208,
Lamp
40°C (100-250W) 40°C (250W ECON)*
240 or 277V or with “E” option which will operate voltages from 200-277V 50/60 Hz. 5 Not recommended for use with Metal Halide lamps due to to rapid yellowing typical of polycarbonate material. 6 For 120V NPF Reactor ballast, drop “H” after wattage in catalog number. 7 Products also available in non-US voltages and 50Hz for international markets. Consult factory for availability and ordering information. 8 480V not available with 200 or 250W Pulse Start Metal Halide. 9 Multi-Tap ballast is 120/208/240/277V wired 277V. 10 Triple-Tap ballast is 120/277/347V wired 347V. 11 Add as suffix in the order shown. 12 Specifications and dimensions subject to change without notice.
LAMP MORTALITY
Lamp Life [Hours]
Ambient
Environment
Supply
Wire (Min.)
90°C
100
90
80
70
% Lumens
60
50
40
2000 4000 6000 10000 8000 12000 14000 16000 18000 20000
®
0
90% Mean Lumens Nat-Wt-ECON 86% Mean Lumens-UPS-ECON 75% Mean Lumens-UPS CWA
LUMEN MAINTENANCE
Lamp Life [Hours]
65% Mean Lumens-Probe Start
• Removable ballast compartment cover provides easy internal access
• Optional “P” mounting bracket fits a standard 4" J-Box or outlet box for surface mounting
• Approximate net weight: 7 lbs. (8 kgs.)