Cooper Lighting OVD15SWW2F4 User Manual

120 STREETWORKS Outdoor Lighting Solutions
Cooper Lighting
ROADWAY
NOTE: 1 150W units are for S55 lamp. 2 Refer to technical section for lamp/ballast/voltage compatibility. 3 Other distributions & cutoffs available. Consult your Streetworks Representative. 4MOV option is not available for any
system requiring a three position terminal block (Example—240V with PCR wired 120V). In order for MOV option to function center terminal of three position terminal block must be connected to “Earth” ground.
HOUSING
Die-cast aluminum housing with stainless steel bail latch. Standard grey polyester powder coat finish. Other finish colors available. Consult your Streetworks Representative. Optional NEMA twistlock photocontrol receptacle also available.
SOCKET
Adjustable mogul-base porcelain socket.
DOOR
Die-cast aluminum door frame with integral hinges for hands free installation, relamping and maintenance. ANSI wattage/source label.
LENS
Removable borosilicate glass refractor for use with High Pressure Sodium, Metal Halide and Mercury lamp sources.
REFLECTOR
The optical system is a hydroformed anodized aluminum reflector with a Dacron polyester filter.
BALLAST ASSEMBLY
Hard mounted ballast with encapsulated starter for protection from environmental abuse. Standard two position tunnel type compression terminal block. Optional swing-down ballast bridge also available (Not available for 3G applications).
MOUNTING
Two-bolt/one bracket slipfitter with cast-in pipe stop and leveling steps. Fixed-in-place birdguard seals around 1 1/4" or 2" mounting arms. (Birdguard not needed for 2" arm.)
ROADWAY LUMINAIRE
OVD DEEP PRISMATIC GLASS
150-400W
MH/HPS/MERCURY
EPA:
Effective Projective Area: .64
SHIPPING DATA
Approximate Net Weight:
35 lbs. (16 kgs.)
ORDERING INFORMATION SAMPLE NUMBER: OVD15SWW2F4
OPTIONS (add as suffix) 1=Single Fuse, Internally Mounted (120 or 277V) 2=Double Fuse, Internally Mounted (208, 240, or 480V) 4=Photocontrol Receptacle WH=White BK=Black BZ=Bronze E=150W/100V/HPS Ballast H=Plug-in Starter Receptacle K=Level Indicator L=Lamp M=MOV Lightning Surge Protector
4
P=Polycarbonate Refractor (250W Max.) T=Swing-down Ballast Bridge U=UL/CSA Listed
ACCESSORIES (order separately) RA1003=Cutoff Visor OA/RA1013=Photocontrol Shorting Cap OA/RA1014=120V Photocontrol OA/RA1016=105V-285V Photocontrol OA/RA1027=480V Photocontrol OA1028=Field Installed PCR Kit OA1218=TufGuard Vandal Shield
OPTIONS + ACCESSORIES [Must be listed in the order shown and separated by a dash]
STREETWORKS
OPTIONS + ACCESSORIES
(See Below)
PRODUCT FAMILY OVD
LAMP WATTAGE 15=150W
1
20=200W 25=250W 31=310W 40=400W 24=250/400W wired 250W 42=400/250W wired 400W
LAMP TYPE
2
S=High Pressure
Sodium
V=Mercury M=Metal Halide
BALLAST TYPE
2
C=CWI M=Mag. Reg. W=CWA R=Reac./NPF P=Hi. Reac./HPF H=Reac./HPF N=Hi. Reac./NPF K=10KV CWA
VOLTAGE
2
2=120V 0=208V 4=240V 7=277V 8=480V 9=347V F=120/240 wired 120V P=240 w/PCR wired 120V W=Multi-Tap wired 120V N=Multi-Tap wired 277V V=Multi-Tap wired 240V
DISTRIBUTION
3
2=Type II 3=Type III
CUTOFF C=SNCO F=MNCO
OPTIONAL COLORS [Standard color is grey, other finish colors available. Consult your Cooper Lighting representative]
WH
White
BK
Black
BZ
Bronze
30" [762mm]
12 3/4"
[324mm]
16 15/16" [430mm]
STREETWORKS Outdoor Lighting Solutions 121Cooper Lighting
OVD DEEP PRISMATIC GLASS ROADWAY
PHOTOMETRICS [Complete IES files available at www.cooperlighting.com]
Light Lens
Wattage Source
1
Type
2
II SNCO II MNCO III MNCO
150 HPS Glass N/A OVD15S2F OVD15S3F
(150W) (150W)
200-250 HPS Glass N/A OVD25S2F OVD25S3F
(250W) (250W)
400 HPS Glass OVD40S2C N/A OVD40S3F
(400W) (400W)
250-400 MH Glass OVD40M2C N/A OVD40M3F
(ED28) (400W) (400W)
250 MV Glass N/A OVD25V2F OVD25V3F
(ED28) (250W) (250W)
NOTE: 1 All light sources are clear unless noted otherwise. 2 Prismatic refractor.
PHOTOMETRIC DISTRIBUTION [Curve Number]
OVD40S3F.IES
400-Watt HPS 50,000-Lumen Clear Lamp Type III-Medium Non-Cutoff
4
3
2
1
0
1
2
3
4
5 4 3 2 1 0 1 2 3 4 5
A B C D E
FOOTCANDLE TABLE
Select mounting height and read across for footcandle values of each isofootcandle line. Distance in units of mounting height.
Mounting Footcandle Values for Height Isofootcandle Lines
ABC D E
OVD40S2C.IES
25' 3.92 1.96 0.98 0.49 0.20 30' 2.72 1.36 0.68 0.34 0.14
35' 2.00 1.00 0.50 0.25 0.10
40' 1.52 0.76 0.38 0.19 0.08
OVD40S3F.IES
25' 3.92 1.96 0.98 0.49 0.20 30' 2.72 1.36 0.68 0.34 0.14
35' 2.00 1.00 0.50 0.25 0.10
40' 1.52 0.76 0.38 0.19 0.08
OVD40S2C.IES
400-Watt HPS 50,000-Lumen Clear Lamp Type II-Short Non-Cutoff
SWING-DOWN BALLAST MODULE
4
3
2
1
A B C D E
5 4 3 2 1 0 1 2 3 4 5
0
1
2
3
4
Loading...