SERIES 75 INSTALLATION MANUAL
Figure 1
STEP 1.
Mount wall angle as shown in Figure 1. Angles must be mounted level and true for fixtures to mount correctly
8'(TYPICAL)
WALL ANGLE PROVIDED IN 8” SECTIONS CUT LAST SECTION TO
FIT AVAILABLE SPACE
FINISHED CEILING
Figure 2
Use tie-wire (by others) to secure and level fixture housings to structure. Based on field dimension pre-cut 4 ft aluminum housing to fit, using hand-saw.
STEP 1.
Attach housing to wall angle. Support housing to structure with tie-wire.
STEP 2.
Install fixture from left to right, beginning with larger housing to smaller. Aluminum housing should be installed on right end of the run.
STEP 3.
Join fixture using joining plates.
JOINING PLATE
STEEL HOUSING
ALIGNER CLIPS
CLEVIS BRACKET
(SEE DETAIL “B”)
1/4"
90° OUTSIDE CORNER
NOTE “A”
·
Re-positioning clevis brackets may be required after cutting aluminum housings
NOTE “B”
·
Last housing of run is aluminum, to be field cut by
installing contractor.
For packing purposes,
·
aligning clips and spacer blades are mounted at end of housing as shown in
detail “A”.
When installing housings,
·
spacer blades will maintain a proper opening.
Prior to housing installation,
·
reposition spacer blades and aligning clips shown in
detail “B”.
Prior to installing shielding
·
element, remove and discard spacer blades for all shielding elements except
S72 bold bae.
STEP 4.
Align fixture using
SPACER BLADE
aligning clips.
Series 75R Installation Manual, Page 1 of 2
100 Andrews Rd., Hicksville, NY 11801 • Phone: 516-470-1000 • Fax: 516-470-1077 • http://www.neoray-lighting.com
A
B
SERIES 75 INSTALLATION MANUAL
Figure 3
LIGHTING STRIPS INSTALLATION (SEE DETAILS A & B) STEP 1. Remove lighting strips covers
STEP 2. Install lighting strips into fixtures (attach to clevis bracket)
STEP 3. Attach first strip to outside power feed
STEP 4. Through wire all strips
STEP 5. Attach lighting strip covers to lighting strips
STEP 6. Install shielding
STEP 7. Install End Closure/End Plate
CHASE NIPPLE
FLEXIBLE CONDUIT (NOT BY NEO-RAY)
DETAIL A
TOP VIEW
DETAIL B
CLEVIS BRACKET
END CLOSURE (FLAT )
END PLATE (FLANGED)
Typical Plan View (Schematic)
TIE-WIRE NOT BY NEO-RAY
6"
3 15/16"
END CLOSURE
STEEL HOUSING
ADJUSTABLE
LIGHT STRIP
ADJUSTABLE STRIP
STAGGERED STRIP
a) 3" STAGGER FOR T8 LAMP b) 6" STAGGER FOR T5 OR T5HO LAMP
LAST HOUSING OF RUN IS FABRICATED OF ALUMINUM TO BE FIELD CUT BY INSTALLING CONTRACTOR.
ALUMINUM HOUSING
90° OUTSIDE CORNER
(O.C.)
WORK FROM LEFT TO
RIGHT WHEN FACING WALL.
LIGHT STRIP
LIGHT STRIP COVER
90° INSIDE CORNER
(I.C.)
WALL RAIL
CEILING TILE
BY OTHERS
3/8"
3 3/16"
4 7/8"±1/8"
FINISH: BLACK
1/4"
5/8"±1/8"
135° OUTSIDE CORNER
Series 75R Installation Manual, Page 2 of 2