11/16/2007 11:28:04 AM
Consult your representative for additional options and finishes.
Specifications and Dimensions subject to change without notice.
Recessed downlight luminaire with 2 inch square regressed pinhole
aperture utilizing a low voltage MR16 tungsten-halogen lamp. Modular
platform can be reconfigured from below the ceiling to accept a broad range
of lamp modules and optical elements. Platform is suitable for direct contact
with insulation and 2x8 residential construction. Platform + module +
element combination supports various lamp beam spreads for desired
optical distribution with excellent light control and low aperture brightness.
Galvanized steel plaster frame with
integral bar hanger receivers.
Setscrews provide positive
Matte black steel collar adjusts
vertically for 1/2" - 1" thick ceilings
and can be rotated +/- 7.5° thru the
aperture. Integral gun sights
facilitate the use of guide strings or
laser lines. Shipped with a paint
overspray protector installed in the
Installed or removed thru the
aperture or from the top and
allows lamp orientation at 0°, 90°,
Double wall aluminum housing
painted matte black for a visually
dark interior. All fasteners are
Closed cell gaskets achieve
restrictive airflow requirements
without additional caulking.
Captive preinstalled bar hangers
adjusts from 8-1/2" to 24" wide;
pass thru feature allows shortening
without removal. Captive nail
engineered lumber. Mounting
flange levels platform with ceiling.
Integral clip attaches directly to
Diecast aluminum splay has
truncated paramid with regressed
square aperture providing minimal
ceiling presence. Can be painted to
match ceiling finish. Mousetrap
type springs pull flange tight to
ceiling. Light trap eliminates spill
light at edge of flange. May also be
installed rimless using optional
plastering lathing ring. Provided
with both straight and angle cut
parabolic shielding cone, shipped
with angle cut version installed.
(7) 1/2" trade size pry outs, (3)
integral clamps for non-metallic
cable. Rated for (4) #12 thru branch
circuits. Wago® type push wire
connectors for field connections
Self-resetting thermal protector
protects against improper lamping.
Integral dual output toroidal
magnetic transformer, 120V
50/60Hz input, 12V nominal 75VA
maximum output. Separate output
for circuits controlled by dimmers
compensates for losses in
temperature and lumen output.
Ceramic GX5.3 lamp holder
mounts to an aluminum heat sink
to dissipate heat. Connects to the
transformer with electrical quick
connects. Accepts 2 lenses, filters
Thermally protected, IP labeled,
cULus listed for damp locations
and ASTM-E283 AIRTITE(tm).
Suitable for direct contact with
50W MR16
Tungsten-Halogen
ENERGY DATA
Lamp Wattage Input Power Input Current
(Nominal) (Watts) (Amps)
20 21 0.17
35 37 .031
37 39 0.32
42 44 0.37
50 53 0.44
14-9/16”
(369mm)
8-1/2”
(216mm)
4-9/16”
(115mm)
4-5/16”
(126mm)
Cutout=5-3/16”
(132mm)
O R D E R I N G I N F O R M AT IO N: C om ple t e u ni t c o ns i st s o f p l a tf o r m , l am p m o d ule a nd o p tic a l el e m e nt .
P408ICAT = 4” Square
Aperture IC Housing
MV4MR = MR16
Vertical Lamp
Module, 120V Input
E4RPIN = 2” Square
Aperture Regressed
Pinhole
Optical Element
Platform
Lamp Module
Flange
P408ICAT MV4MR
Accessories
Blank] = Self Flanged,
Matte White Flange
RL = Rimless, Matte
White Flange
PLR4x4 = Plaster Lathing Ring
(For Use With E4PINRL Only)
RLA4x4 = Rimless Adapter
(For Use With E4PINRL Only)
LSA16 = Matte black lamp snoot accessory
L Series - Filter Media For MR16 lamps
(See Accessories specification sheet)
Specifications and Dimensions subject to change without notice.
Photometric Results
Spacing Criterion = .1
Efficiency = 41.3%
Test No. P10511
Platform = P406TAT
Element = E4RPIN
Lumens = 575
Lamp = 42MR16 VNSP9
42W
MR16
Candlepower Distribution
3000
6000
9000
Downlight
45°
30°15°0°
60°
75°
90°
Cone of Light
Coefficients of Utilization
D FC Beam Dia
8'0"
9'0"
10'0"
13'0"
15'0"
131
104
84
50
37
1.0
1.2
1.3
1.7
2.0
Candelas
Vertical
Angle
CD
90
85
75
65
55
45
35
25
15
5
0
0
0
0
0
0
0
4
17
112
2694
8405
Ceiling
Wall %
RCR
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal cavity method -- floor reflectance = 20%
0
1
2
3
4
5
6
7
8
9
10
49 49 49 49
48 47 47 46
47 46 45 44
46 45 44 43
45 44 43 42
45 43 42 41
44 42 41 40
43 42 40 40
43 41 40 39
42 41 40 39
42 40 39 39
48 48 48 48
47 46 46 45
46 45 44 44
45 44 43 42
45 43 42 41
44 43 41 41
43 42 41 40
43 41 40 40
43 41 40 39
42 40 39 39
42 40 39 38
46 46 46
45 44 44
44 43 43
43 42 42
42 42 41
42 41 40
41 41 40
41 40 39
41 40 39
40 39 39
40 39 38
44 44 44
43 43 43
43 42 42
42 42 41
42 41 41
41 41 40
41 40 40
41 40 39
40 39 39
40 39 39
40 39 38
42 42 42
42 42 41
42 41 41
41 41 41
41 41 40
41 40 40
41 40 39
40 40 39
40 39 39
40 39 39
39 39 38
41
41
40
40
40
39
39
39
39
38
38
Zonal Lumens Summary
Zone Lumens % Lamp % Luminaire
0- 30
0- 40
0- 60
0- 90
90-180
0-180
234
237
237
237
0
237
40.8
41.3
41.3
41.3
0
41.3
98.8
100
100
100
0
100
Photometric Results
Spacing Criterion = .2
Efficiency = 39.8%
Test No. P10535
Platform = P406TAT
Element = E4RPIN
Lumens = 1320
Lamp = 50MR16 IR SP10
50W
MR16
Candlepower Distribution
4000
8000
12000
Downlight
45°
30°15°0°
60°
75°
90°
Cone of Light
Coefficients of Utilization
D FC Beam Dia
8'0"
9'0"
10'0"
13'0"
15'0"
177
140
113
67
50
1.3
1.5
1.6
2.1
2.5
Candelas
Vertical
Angle
CD
90
85
75
65
55
45
35
25
15
5
0
0
0
0
0
0
0
12
73
360
5711
11325
Ceiling
Wall %
RCR
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal cavity method -- floor reflectance = 20%
0
1
2
3
4
5
6
7
8
9
10
47 47 47 47
46 46 45 44
45 44 43 42
44 43 42 41
43 42 40 40
42 41 39 39
42 40 39 38
41 39 38 37
40 39 37 37
40 38 37 36
39 38 36 36
46 46 46 46
45 45 44 44
44 43 42 42
43 42 41 40
43 41 40 39
42 40 39 38
41 40 39 38
41 39 38 37
40 38 37 37
40 38 37 36
39 37 36 36
44 44 44
43 43 42
42 41 41
41 40 40
40 40 39
40 39 38
39 38 37
39 38 37
38 37 36
38 37 36
37 36 36
42 42 42
42 41 41
41 40 40
40 40 39
40 39 38
39 38 38
39 38 37
38 37 37
38 37 36
37 36 36
37 36 35
41 41 41
40 40 40
40 40 39
40 39 39
39 39 38
39 38 38
38 38 37
38 37 37
38 37 36
37 36 36
37 36 35
40
39
39
38
38
37
37
36
36
36
35
Zonal Lumens Summary
Zone Lumens % Lamp % Luminaire
0- 30
0- 40
0- 60
0- 90
90-180
0-180
517
525
526
526
0
526
39.2
39.8
39.8
39.8
0
39.8
98.4
99.9
100
100
0
100
IRiS • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
11/16/2007 11:28:04 AM
ADI070185