Cooper Lighting Metalux RCG User Manual

COOPER LIGHTING - METALUX
®
STRIPS
RCG SERIES
4', 6' or 8' 1, 2 or 3 Lamps
RECESSED LIGHTING SYSTEM
• Equipped with energy saving ballast/complies with federal energy efficiency standards
• One piece die formed steel raceway reflector assembly
• Designed to direct 50% more light into the work plane area
• Reflector finish reduces high angle glare by over 50%
• Compatible with all inverted T-Grid ceilings 1' x 4' and 1' x 8' modules
• Optional continuous row fixtures available
• Simplified unit or row installation
• Full access wireway
• Baked white enamel finish
• Optional enhanced recessed silver steel reflector reduces high angle glare by over 70% and provides superior visual comfort (SilverLining only)
DIMENSIONSDESCRIPTION
The RCG Series is a fully assembled, one-piece recessed lighting system that provides an unobstructed, visually comfortable, ceiling plane with a reduction high angle ceiling glare of over 50%. The optional SilverLining option reduces high angle glare over 70%. The series produces excellent, uniform, low brightness linear illumination. The RCG can be utilized with new high color rendition light sources, along with high performance ballasts for system efficiency and performance. The RCG Recessed Lighting System
NOMINAL LENGTH A B (HO Ballast) C (RS, SL Ballast)
4'/8', 1/2 Lamp 11-3/4" (299mm) 6-1/8" (156mm) 5-1/8" (130mm)
4'/8', 3 Lamp 11-3/4" (299mm) NA 5-1/8" (130mm)
complements general task and retail merchandising areas. The RCG is ideal for mass merchandising areas where the focus is on a product with visual appeal.
ORDERING INFORMATION
SAMPLE NUMBER: RCG-232A-120V-EB81-U
Tandem Blank=4'
Length 8T=8' Tandem
RC=Series
Continuous Row G=Standard Fixture
(Single) (2 End Plates Furnished) C=Continuous Row (In Row) (No Reflector End Plates) E=Continuous Row (End of Row) (1 End Plate Furnished)
Rails Blank=Open,
no Lens/Rail A=Factory Installed Lens and Rail
Number of Lamps 1, 2 or 3 lamps
(Not Included)
(4)
Wattage (Length) 40=34/40W T12 (48")
(5)
32=32W T8 (48") 48=40W T12 (48") SL
(5)
48HO=60W T12 (48") HO 48HO=44W T8 (48") HO 72=55W T12 (72") SL 72HO=85W T12 (72") HO 72HO=65W T8 (72") HO 96=60/75W T12 (96") SL 96=59W T8 (96") SL 96HO=95/110W T12 (96") HO 96HO=86W T8 (96") HO
SilverLining SS=Reflector and
Wireway Cover
(1)
Voltage 120V=120 Volt 277V=277 Volt
(3)
347V=347 Volt UNV=Universal Voltage 120-277
Options GL=Single Element Fuse GM=Double Element Fuse Emergency - for EM installed,
see EM options table
(7)
(7)
Options
(6)
Ballast Type Blank=Standard Magnetic Ballast LE3=T12 Magnetic Energy Saving
= T8 Electronic Instant Start.
EB8
No. of Ballast
(2)
1, 2 or 3
/PLUS= T8 Electronic Instant Start.
EB8
No. of Ballast 1, 2 or 3
= T8 Electronic Program Rapid Start.
ER8
No. of Ballast 1, 2 or 3
=T12 Electronic Rapid Start.
EB2
No. of Ballast 1 or 2
(For complete details on generic or to specify manufacturer’s ballast see pg. 469)
(See Options Section)
(1)
Total Harmonic Distortion < 10%
High Ballast Factor >1.13. Total Harmonic Distortion < 20%
Total Harmonic Distortion < 10%
Packaging U=Unit Pack
• UL/CUL Listed. Suitable for damp locations.
COOPER LIGHTING
434
(1)
NOTES:
Products also available in non-US voltages and frequencies for international markets.
(3)
3-lamp fixture available with T8 lamps only.
(7)
lamps.
296 and 296HO with LE3 only available in 120V.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
(4)
RCG fixture requires cross tees.
(5)
RCC and RCE fixtures do not require cross tees.
(2)
Not available when specifying emergencies, voltage must be specific.
(6)
Not available on fixtures using HO