SPECIFICATION FEATURES
07/01/2008 11:14:52 AM
Consult your representative for additional options and finishes.
Specifications and Dimensions subject to change without notice.
ADF060954
LAMP CONFIGURATIONS
DIMENSION TOP VIEW
DESCRIPTION
The HBOT series is an outstanding solution for high mounting height
industrial or retail applications. The HBOT optic has been optimized to
provide maximum performance. Optional uplight component is provided to
enable excellent ceiling uniformity. HBOT's high lumen package allows the
benefits of fluorescent to be applied at high mounting heights that were
traditionally exclusive to H.I.D. The primary benefits include exceptional
color rendering, high system efficacy, 95% lumen maintenance, long lamp
life, instant on/instant re-strike, economical dimming, and uniform
brightness control. Primary applications include retail, shopping malls, light
industrial, and recreational environments.
A ... Construction
Specification grade open body
housing, end plates and socket
tracks are die formed 20-gauge
cold rolled steel. The HBOT
channel provides strength and
numerous KOs for easy
installation. Top Ballast Access
Plate. Allows for removal or
service of ballast from above
without removal of lamps. Die
formed external reflectors are
available in both high reflectance
specular material or in painted-
after-fabrication white enamel.
B ... Electrical
Class "P" ballasts are positively
secured by mounting bolts.
Roto-lock lampholders. Optional
modular power receptacle and
cord sets meets UL2459 and NEC
410.73 and are UL/cUL rated for
make and break under load from
outside the luminaire. UL/CUL
listed. Suitable for damp locations.
Thermally optimized for environ-
ments up to 122°F (50°C) when
used with high temperature
ballasts.
C ... Finish
Electrostatically applied baked
white enamel finish is preceded by
a multistage cleaning cycle, iron
phosphate coating with rust
inhibitor.
D ... Downlight/Uplight Optics
Die formed reflectors are faceted
for 8 lamp configurations with two
optical distributions - medium and
wide. Medium beam optical
modules utilize 95% specular
aluminum while the wide distri-
bution utilizes a high performance
95% reflective polyester powder
coated finish. Uplight option
provided to enable ceiling
uniformity.
Mounting
The HBOT series is suited for
surface or suspension mounting
with wire hook and chain set, stem
or cable mounting. Optional top
connector box mounting is
available.
F-BAY
HBOT T8 SERIES
Nominal 3' x 4' High-Bay
(8) T8 Lamps
HIGH-BAY INDUSTRIAL
OPEN TOP LUMINAIRE
E N E R G Y D ATA
Input Watts:
EB Ballast
832 = 218
EB/Plus Ballast
832 = 294
ER Ballast
832 = 224
ER/Plus Ballast
832 = 288
Luminaire Efficacy Rating
LER = 77 (White) LER = 84 (Specular) Catalog Number: 3HBOT-832-UPL
Yearly Cost of 1000 Lumens, 3000 hrs. at .08 KWH = $2.84
* Reference the lamp/ballast data in the Tecnical Section for specific lamp/ballast requirements
** Consult Pre Sales Technical Support.
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power
5-3/16"
[131mm]
32-11/16" [830mm]
A
BC D
32-11/16" [830mm]
X
X
X
X
X
X
X
5-3/16" [131mm]
X=4"
[102mm]
8-Lamp
48-1/16" [1221mm]
11/16" X 1" KO (2)
7/8" KO (4)
Ceiling Standoff Embossment
Top Connector Emboss
33" [838mm]
41-1/2" [1054mm]
32-11/16" [830mm]
8-Lamp
COOPER LIG H T ING - META L U X
®
Specifications and Dimensions subject to change without notice.
PHOTOMETRICS
SHIPPING INFORMATION
ORDERING INFORMATION
HBOT
C oe ffi ci en ts o f Uti li za ti on
Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0 1 2 3 4 5 6 7 8 9
10
Z on al Lu me n Su mm ar y
Zone Lumens %Lamp %Fixture
0-30 0-40 0-60 0-90 0-180
C an de la
Angle Along II 45° Across
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
3HBOT-832-UPL
(2) Electronic Ballasts (8) 32W T8 lamps
3000 lumens Spacing criterion:
(II) 1.3 x mounting height, ( ) 1.3 x mounting height
Efficiency 89.8% Test Report: 18445
LER =84 Yearly Cost of 1000
lumens, 3000 hrs at .08 KWH = $2.84
9244 9244 9244 9215 9146 9136 9092 8966 8971 8882 8776 8995 8595 8674 8786 8228 8404 8223 7779 7876 7417 7261 7129 6852 6670 6294 5874 6025 5639 4647
5311 4603 3196 4574 3427 1921 3783 2141 954 3000 1061 309 2204 378 30 1442 46 13
765 18 1 250 30 21
13 1 1
106 106 106 106 103 103 103 103 98 98 98 93 93 93 88 88 88 86 99 95 92 89 96 93 90 87 88 86 84 84 83 81 81 79 78 76 91 85 80 75 88 83 78 74 79 75 72 76 73 70 73 70 68 66 84 76 69 64 81 74 68 63 71 66 62 68 64 60 65 62 59 57 77 68 61 56 75 66 60 55 64 58 54 61 57 53 59 55 52 50 72 61 54 49 70 60 53 48 58 52 47 56 51 46 54 49 46 44 66 55 48 43 64 54 48 43 52 46 42 51 45 41 49 44 41 39 62 50 43 38 60 50 43 38 48 42 37 46 41 37 45 40 36 35 58 46 39 34 56 45 39 34 44 38 34 43 37 33 41 37 33 31 54 43 36 31 52 42 35 31 41 35 30 39 34 30 38 33 30 28 50 39 33 28 49 39 32 28 38 32 28 37 31 27 36 31 27 26
7164 29.8 33.2
11585 48.3 53.8 18756 78.2 87.0 20692 86.2 96.0 21549 89.8 100.0
L um in an ce Da ta
Average Average Average Angle 0-Deg 45-Deg 90-Deg in Deg cd/sm cd/sm cd/sm
45 8579 8030 6617 55 8029 6016 3372 65 7148 2527 735 75 5611 178 49 85 2887 344 237
Cooper Lighting’s F-Bay Modular Power Supply option allows external fixture access for safe and easy servicing. There is no need to remove lamps or reflectors to disconnect fixture power with F-Bay Modular Power Supply. Access to the individual fixtures power supply allows servicing without turning off all the fixtures disrupting occupants. F-Bay Modular Power Supply is a time saver in installation – simply plug & power.
1 2
Modular F-Bay Power Supply
1. Modular Power Supply Receptacle supplied
mounted into fixture Access Plate.
2. Modular Power Cord & Plugs in 120, 277, 347, & 480V configurations for easy plug & power into existing supply.
No internal fixture access required for installation or disconnecting power.
Code Compliance
• UL/cUL Certified for Make/Break under load (UL2549)
• Meets NEC requirements for ballast disconnect (NEC 410.73G)
• Allows for addition of Occupancy Sensor without hard connections
• Receptacles complete with insulating dustcap
Modular Motion Sensor Option supplied with Mounting Box and Modular Power Supply Receptacle.
3HBOT-832-G-120V-UPL 27 lbs.
.tW.oN golataC
S AM PL E N U MB E R : 3 HB OT- 83 2- UN V-E B8 2/ PL US -U PL- U
No. of Lamps 8=8 Lamps
Lamp Type 32=32W T8 (4') Lamp
Series HBOT=High Bay Open
Top Version
Width 3=32" wide
Voltage
(2)
UNV=Universal
120/277 Voltage UNC=Universal 347/480 Voltage (T5 linear only)
(6)
120V=120 Volt 277V=277 Volt 347V=347 Volt 480V=480 Volt
Distribution Blank=Medium (Specular Aluminum) G=Wide (White Painted)
Options UPL=Uplight Apertures MWS=Modular Wiring System MS=Aisle Coverage Motion
Sensor
(4)
MSO=360° Coverage Motion
Sensor
(4)
MP=Modular Power Receptacle
(1) (2)
PC3-=3' Power Cord & Plug (Specify Voltage)
(2)
PC6-=6' Power Cord & Plug (Specify Voltage)
(2)
TCBP=Top Connector Box Plate
(5)
Packaging U=Unit Pack PAL=Palletized
Out of Carton PALC=Palletized In Carton
Options Lamps Installed L8830=T8 Lamp, 85CRI 30 00K L8835=T8 Lamp, 85CRI 350 0K L8841=T8 Lamp, 85CRI 4100K L8850=T8 Lamp, 85CRI 50 00K
GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed
(2)
Ballast Type T8 Systems EB8
=T8 Electronic Instant Start.
(7)
Total Harmonic Distortion < 10%
EB8 /PLUS=T8 Electronic Instant Start.
(7)
High Ballast Factor >1.15. Total Harmonic Distortion < 10%
ER8
=T8 Electronic Program Rapid Start.
(7)
Total Harmonic Distortion < 10%
ER8 /PLUS=T8 Electronic Program Start.
(7)
High Ballast Factor >1.15. Total Harmonic Distortion < 10%
No. of Ballast 2 or 3
No. of Ballast 2 or 3
No. of Ballast 2 or 3
NOTES:
(1)
Requires use of MC or MPC cord accessories, specify voltage for plugs.
(2)
Voltage must be specified when ordered with plugs, motion or emergency
ballasts.
(4)
Specify voltage on ballast.
(5)
For use with Top Connector Box options. See accessories.
(6)
2 lamp ballast configurations only in EHT-UNC versions.
(7)
ER8 and EB8 ballast systems suitable for operation in ambient environments up to 122°F (50°C) in open uplight configuration.
Accessories (order separately) AYC-CHAIN/SET/U=(2) Hooks, 36" Chain
Sets w/S-Hooks
TCB=Top Connector Box RH-1=Retrofit Hanger FH-1=Fixture Hook FL-1=Fixture Loop MPC6=6' Modular Power Cord & Plug
(Specify Voltage)
MC6=6' Modular Power Cord MMS-CPD1200H=Aisle Motion Sensor,
Box, Modular Power Receptacle (120/277V) MMS-CPD500H=360° Motion Sensor, Box, Modular Power Receptacle (120/277V)
No. of Ballast 2 or 3
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801