Cooper Lighting Metalux BC SERIES Specification Sheet

Page 1
Starting Type LTS=Low Trigger Start
(20 Watt only) (120V only) HTS=High Trigger Start (20 Watt only)
WALL BRACKETS
430
DIMENSIONS
• Equipped with energy saving ballasts/complies with federal energy efficiency standards
• Contemporary styling
• Die formed steel housing
• Baked white enamel finish
• Extruded smooth opal white acrylic refractor
• 180° uniform light distribution
• Decorative opaque injection molded white end caps
• Easy wiring access
• Vertical wall or horizontal ceiling mounting application
• Grounded convenience outlet and switching available, see Options page
• UL/CUL Listed. Suitable for damp locations.
DESCRIPTION
The BC Series is an energy efficient luminaire designed for versatility in application and performance. The BC Series features an opal white acrylic refractor that produces a 180° uniform light distribution pattern. The versatile BC Series combines quality and economy in a multi-purpose wall bracket. The luminaire is perfect for illuminating corridors, stairwells, lavatories, dressing rooms, patient rooms, utility/task and area lighting.
BC SERIES
2', 3' or 4' 1 or 2 Lamps
ALL PURPOSE WALL BRACKET
NOMINAL LENGTH A B
2', 3', 4' 4-1/4" (108mm) 4-1/4" (108mm)
ORDERING INFORMATION
SAMPLE NUMBER: BC-232-120V-EB81-U
Number of Lamps 1 or 2 lamps
(Not Included)
Wattage (Length) 20=20W T12 (24") 17=17W T8 (24") 30=30W T12 (36") 25=25W T8 (36") 40=40W T12 (48") 32=32W T8 (48")
Voltage
(1)
120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277
(2)
Options GL=Single Element Fuse GM=Double Element Fuse Emergency - for EM installed, see EM
options table
(3)
BC=Series
Options
(See Options Section)
Packaging U=Unit Pack
Ballast Type
(1)
Blank=Standard Magnetic Ballast
(20W only)
LE3=T12 Magnetic Energy Saving EB8
= T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
EB8
/PLUS= T8 Electronic Instant Start.
High Ballast Factor >1.13. Total Harmonic Distortion < 20%
ER8
= T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
EB2
=T12 Electronic Rapid Start.
(For complete details on generic or to specify manufacturer’s ballast see pg. 469)
No. of Ballast 1, 2 or 3
No. of Ballast 1, 2 or 3
No. of Ballast 1, 2 or 3
No. of Ballast 1 or 2
NOTES:
(1)
Products also available in non-US voltages and frequencies for international markets.
(2)
Not available when specifying emergencies, voltage must be specific.
(3)
Non available for 2' version.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
COOPER LIGHTING - METALUX
®