Cooper Lighting Metalux AC128T5, Metalux AC154T5 User Manual

Catalog #
Project
Comments
Prepared by
Date
SPECIFICATION FEATURES
08/12/2008 2:37:31 PM
Consult your representative for additional options and finishes.
Specifications and Dimensions subject to change without notice.
ADF051799
CEILING COMPATIBILITY
MOUNTING DATA
LAMP CONFIGURATIONS
DESCRIPTION
The accord(TM) redefines fluorescent lighting by improving on aesthetics,
comfort and energy savings. The accord(TM) provides the right amount of
light while eliminating surface shadows commonly found in parabolics.
Therefore, accord(TM) increases the comfort level while providing
significant energy savings.
The accord(TM) is the ideal solution for offices, schools, hospitals, retail and
other applications.
A ... Construction
Shallow 3-1/4" deep housing is die
formed of code gauge, prime cold
rolled steel. Heavy gauge end
plates are securely attached with
screws for strength and rigidity
and the elimination of gaps. Four
auxiliary fixture end suspension
points are provided. Large access
plate for supply connection.
B ... Electrical*
Ballasts are Class "P" and are
positively secured. Rotor-lock
lampholders ensure positive lamp
retention. UL/CUL listed. Suitable
for damp locations.
C ... Ballast Access
Ballast is mounted on a heavy
gauge access plate and can be
accessed from above the ceiling
line.
D ... Finish
Durable cold rolled steel with
multistage, iron phosphate
pretreatment and white enamel
finish to ensure maximum bonding
and rust inhibition.
E ... Reflectors
Reflector has high reflectance
baked matte white enamel finish
for luminous uniformity.
F ... Shielding
Positively retained frosted acrylic
profile lenses provide a soft but
effective distribution of light.
AC
128T5 154T5
T5 LAMP
1' X 4' Recessed
Troffer Series
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power
G
G r i d / L a
y- i n
S t a n d a r
d
F
D r y
wall Fr a m e
K i
t
C e i l i n
g Tri m
Ty p e** Ty p e
Exposed Grid G Conceale
dT G or T
Slot Grid G or
T
F l a n g e * * *
EB Ballast & STD Lamps @ 277V
128T5 (34)
Luminaire Efficacy Rating
LER =FL64 LPW Catalog Number: AC-128T5
Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.88
*Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements.
**Consult Pre Sales Technical Support.
***See Drywall Frame Kit Accessory
E N ER G Y DAT A
Input Watts:
11-3/4"
[299mm]
48-3/8" [1229mm]
6"
[153mm]
X
Y
A B CDF E
COOP ER LI GHT IN G - META LUX
®
Specifications and Dimensions subject to change without notice.
ORDERING INFORMATION
PHOTOMETRICS
SHIPPING INFORMATION
AC
S A M PL E NU MB ER : A C- 12 8T 5- UN V-E BT 1N DI M
Number of Lamps
(Not included)
1=1 Lamp
Wattage (Length) 28T5=28W T5 (48") 54T5=54W T5HO (48")
Voltage
(1)
UNV=Universal Voltage
120-277
Options GL=Single Element Fuse GM=Double Element Fuse Flex=Flex installed EL=Emergency Installed
Packaging U=Unit Pack PALC=Job Pack,
in carton
Shielding Blank=Frosted Acrylic
(standard)
Ballast Type EBT =T5 Linear Electronic
Program Rapid Start Total Harmonic Distortion < 10%
Ballast Factor/Type
(For 28W T5 Lamp Only)
N=Normal Light Output .95 BF
(2)
H=High Light Output 1.15 BF
(2), (4)
NDIM=Normal .95-1.0 BF Step Dimming
(3)
HDIM=High 1.15 BF Step Dimming
(3), (4)
NOTES:
(1)
Products also available in non-US voltages and frequencies for international markets.
(2)
.95 and 1.15 ballast factor available for 28W T5 lamps only.
(3)
Step Dimming ballast available for 28W T5 lamps only.
(4)
1-Lamp ballast in the High Ballast factor not available. 2-Lamp ballast will not operate 1-Lamp.
(5)
1' x 4' Accord is not designed for continuous row mount applications. For complete product data, reference the
Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
No. of Ballast 1 or 2
Lamps L5835=T5 Lamp,
3500K L5841=T5 Lamp, 4100K L5835HL=T5 Lamp, 28W, 3500K, 2900 Lumens L5841HL=T5 Lamp, 28W, 4100K, 2900 Lumens
Series AC=Accord Series
Width
(5)
Blank=1' Width
Rating Blank=
Standard NY=New York Rated ATW-SW4= Chicago Rated
C o e f fi c i e n t s o f Ut i l i z a t i o n
Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0 1 2 3 4 5 6 7 8 9
10
L u m i n a n c e Da t a
Average Average Average Angle 0-Deg 45-Deg 90-Deg in Deg cd/sm cd/sm cd/sm
45 1768 2084 2285 55 1659 2119 2395 65 1501 2125 2125 75 1195 1600 1382 85 555 463 339
Z o n a l L u m e n S u m m a r y
Zone Lumens %Lamp %Fixture 0-30 0-40 0-60 0-90 0-180
||
C a n d l e p o w e r
Angle Along II 45° Across
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
AC-128T5
Electronic Ballast F28T5/835 Lamps 2600 Lumens Spacing criterion:
(II) 1.2 x mounting height, ( ) 1.4 x mounting height
Efficiency 87.4% Test Report:
241P113 LER = FL62 Yearly Cost of 1000
lumens, 3000 hrs at .08 KWH = $3.88
738 738 738 734 736 736 723 730 732 705 718 725 679 701 715 647 679 702 609 654 685 565 623 663 517 588 635 465 548 601
411 502 559 354 452 511 295 396 443 236 334 334 175 248 221
115 154 133
60 75 63 18 15 11
0 1 1
104 104 104 104 102 102 102 102 97 97 97 93 93 93 89 89 89 87 95 91 87 84 93 89 86 83 85 82 80 82 80 77 79 77 75 73 86 79 73 68 84 77 72 67 74 70 66 71 68 64 69 66 63 61 78 69 62 56 76 68 49 56 65 5 9 55 63 58 54 60 56 53 52 72 61 53 47 70 60 43 47 58 51 46 56 50 46 54 49 45 43 66 54 46 40 64 53 38 40 51 45 40 50 44 39 48 43 39 37 61 49 41 35 59 48 34 35 46 40 35 45 39 34 43 38 34 32 56 44 36 31 55 43 31 31 42 35 30 41 35 30 40 34 30 28 52 40 33 27 51 40 28 27 38 32 27 37 31 27 36 31 27 25 49 37 29 25 47 36 25 24 35 29 24 34 28 24 33 28 24 22 46 34 27 22 44 33 23 22 33 26 22 32 26 22 31 26 22 20
585 22.5 25.8
973 37.4 42.8 1788 68.8 78.7 2271 87.4 100.0 2271 87.4 100.0
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801