Cooper Lighting Metalux 388, Metalux 2P5GAX User Manual

COOPER LIGHTING - METALUX
®
PARALUX V
2P5GAX SERIES
1' x 2', 1' x 4', 2' x 2', 2' x 4', 20" x 24" or 20" x 48" Parabolic 1, 2 or 3 Lamp Parabolic Louver
PARALUX V RECESSED AIR SUPPLY PRECISION CUT-OFF TROFFER
• Equipped with energy saving ballast/complies with federal energy efficiency standards
• Computer designed, precision cell louver technology
• Louver designed to eliminate objectionable glare in the VDT screen
• Low iridescent louver minimizes iridescence
• Field convertible feature
• Floating louver/black reveal
• Efficient air handling options
DLS Dimming Ballasts are
available
• End plate grid-lock
• For information on flanged
• UL/CUL Listed. Suitable for
(1)
feature
fixture, including ceiling opening size, see Technical Section.
damp locations.
DESCRIPTION
DIMENSIONS
The Paralux V series features a proprietary “Total Light Control System” that has been designed to eliminate glare reflections in VDT screens by suppressing high angle brightness. Meets today’s lighting standards. The luminaire incorporates a precision cut-off parabolic louver in a para­contoured fixture housing. This system complies with RP-1 and meets today’s lighting and energy manage-ment standards. The series is compatible with all of today’s popular ceiling systems. The Paralux V, PC|2 series is the solution for computer environ-ments and open office areas.
ORDERING INFORMATION
SAMPLE NUMBER: 2P5GAX-332S39MI-120V-EB81-U
HM= Hard
Metric
HR=Heat
(1)
Removal HRDO=Heat Removal Damper Open HRDC=Heat Removal Damper Closed
Width 2'=2' width Blank=1' width or
20" width
P=Paralux Louver
5=5" Louver Depth
Trim Type G=Grid/Lay-in – Standard G or T=Concealed T G or T=Slot Grid F=Flange Trim MZ=Modular Trim
Convertible Fixture Standard G (Grid)
Type-Fixtures can be field converted to T-option or vice-versa. adaptable with flanged or modular trims.
AX=Air Supply Floating Louver X=Blank Side/Floating Louver - Non-Air Supply (Omit A) AVX=Air Supply Floating Louver with Directional Air Vane (Add V)
PRODUCT INFORMATION FOR PARALUX V
Housing Lamp Louver Cell Number
Size Quantity Configuration* of Cells
1' x 2' 1 or 2 14 4
1' x 4' 1 or 2 19 9
2' x 2' 2 24 8
20" x 24" 2 24 8
20" x 48" 2 29 18
2' x 4' 2 29 18
*Example: 39= 3 rows of 9 (27 cells)
(2)
(3)
Fixture also
3 34 12
3 39 27
NOMINAL SIZE A B
1' x 2' 11-3/4" (298mm) 7" (178mm) 1' x 4' 11-3/4" (298mm) 7" (178mm) 2' x 2' 23-3/4" (603mm) 6-1/8" (156mm) 2' x 2' (8 cell) 23-3/4" (603mm) 6-3/4" (171mm) 2' x 4' 23-3/4" (603mm) 6-1/8" (156mm) 2' x 4' (18 cell) 23-3/4" (603mm) 6-5/8" (168mm) 20" x 24" 19-3/4" (502mm) 6-1/8" (156mm) 20" x 48" 19-3/4" (502mm) 7-3/8" (502mm)
Number of Lamps 1, 2 or 3 lamps
(Not included)
Wattage (Length) 17=17W T8 (24") U15/8=31W T8 (24") BX40=40W Biaxial (24") 32=32W T8 (48")
Louver Color S=Silver
Cell Configuration*
(See below for Louver Options)
Louver Finish MI=Specular/Mirrored (Low Iridescent) VDT=VDT Soft Semi-Specular/Haze
(Low Iridescent) WB=White & Black Longitudinal Louver Blades (Specular/Mirrored Cross Blades) 1x4 only WBVDT=White & Black Longitudinal Louver Blades (VDT Soft Semi­Specular/Haze Cross Blades) 1x4 only
WW
Wall Wash
(4)
Voltage UNV=Universal
Voltage 120-277
347V=347 Volt
Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Lamps - for lamps installed, see
lamp options table Flex - for flex installed, see flex ordering table Emergency - for EM installed, see EM options table
Ballast Type Blank=Standard Magnetic Ballast (Biax & 20W)
= T5 Biax Electronic Instant Start. Total
EB5
No. of Ballast 1, 2 or 3
LE3=T12 Magnetic Energy Saving
=T12 Electronic Rapid Start.
EB2
No. of Ballast 1 or 2
ER8 = T8 Electronic Program Rapid Start. Total
No. of Ballast 1, 2 or 3
= T8 Electronic Instant Start. Total Harmonic
EB8
No. of Ballast 1, 2 or 3
/PLUS= T8 Electronic Instant Start. High
EB8
No. of Ballast 1, 2 or 3
TEB5
No. of Ballast 1, 2 or 3
DLS=Digital Lighting System Dimming
(For complete details on generic or to specify manufacturer’s ballast see pg. 469)
(5)
(4)
Harmonic Distortion < 20%
Harmonic Distortion < 10%
Distortion < 10%
Ballast Factor >1.13. Total Harmonic Distortion < 20%
=T5 Biax Electronic Instant Start. Total
Harmonic Distortion < 10%
Options
(See Options Section)
Packaging U=Unit Pack PAL=Job Pack,
out of carton PALC=Job Pack, in carton
COOPER LIGHTING
388
(1)
NOTES:
Integral end plate grid lock feature not available in heat removal.
housing only, appropriate shielding media assemblies must be utilized.
(5)
Not available when specifying emergencies, voltage must be specific.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
(2)
An EQ Grid Clip is recommended for all 9/16" ceiling systems.
(4)
Products also available in non-US voltages and frequencies for international markets.
(3)
Convertibility applies to
PERFORMANCE INFORMATION
COOPER LIGHTING - METALUX
PARALUX V
®
RP-1 1ST LEVEL
The concept of RP-1 is simple; by suppressing high angle brightness, reflected glare will be avoided in the VDT screen at the normal tilt angle. The 1st level sets the toughest standard.
The 1st level or preferred level states that the average luminance brightness in the lengthwise (0°), crosswise (90°) and 45° lateral planes should not exceed the following:
Candelas/M
850 Candela/sm at 55° from vertical 250 fl at 55° from vertical 350 Candela/sm at 65° from vertical 100 fl at 65° from vertical 175 Candela/sm at 75° from vertical 50 fl at 75° from vertical 175 Candela/sm at 85° from vertical 50 fl at 85° from vertical
2
Footlamberts (English)
RP-1 2ND LEVEL
The 2nd level is relaxed. It is suitable for areas where intermittent computer work stations exist.
The 2nd level states that in no case shall the luminance brightness exceed the following in the lengthwise (0°), crosswise (90°) and 45° lateral planes:
Candelas/M
850 Candela/sm at 65° from vertical 250 fl at 65° from vertical 350 Candela/sm at 75° from vertical 100 fl at 75° from vertical 175 Candela/sm at 85° from vertical 50 fl at 85° from vertical
2
Footlamberts (English)
This view of the ceiling and room space illustrates the vertical plane with vertical angles (light/dark grey area) from 0° to 90° in the 0° (lengthwise) lateral plane. Notice the light grey areas. This is where the Metalux Precision Parabolic bends the light into a confined cut­off-zone, 0° to 55°, (1st level). Now notice the dark grey areas. This is where the light is restricted in the shielded zone, thus eliminating high angle brightness (glare) in the VDT screen.
This view of the ceiling and room space illustrates the vertical plane with vertical angles (light/dark grey area) from 0° to 90° in the 0° (lengthwise) lateral plane. Notice the light grey areas. This is where the Metalux Precision Parabolic bends the light into a confined cut-off­zone, 0° to 65°, (2nd level). Now notice the dark grey areas. This is where the light is restricted in the shielded zone, thus eliminating high angle brightness (glare) in the VDT screen.
COOPER LIGHTING
389