COOPER LIGHTING - METALUX
®
PARALUX V
2P5GAX SERIES
1' x 2', 1' x 4', 2' x 2',
2' x 4', 20" x 24" or
20" x 48" Parabolic
1, 2 or 3 Lamp
Parabolic Louver
PARALUX V RECESSED
AIR SUPPLY PRECISION
CUT-OFF TROFFER
• Equipped with energy
saving ballast/complies
with federal energy
efficiency standards
• Computer designed,
precision cell louver
technology
• Louver designed to
eliminate objectionable
glare in the VDT screen
• Low iridescent louver
minimizes iridescence
• Field convertible feature
• Floating louver/black reveal
• Efficient air handling options
•
DLS Dimming Ballasts are
available
• End plate grid-lock
• For information on flanged
• UL/CUL Listed. Suitable for
(1)
feature
fixture, including ceiling
opening size, see Technical
Section.
damp locations.
DESCRIPTION
DIMENSIONS
The Paralux V series features a
proprietary “Total Light Control
System” that has been designed
to eliminate glare reflections in
VDT screens by suppressing high
angle brightness. Meets today’s
lighting standards. The luminaire
incorporates a precision cut-off
parabolic louver in a paracontoured fixture housing. This
system complies with RP-1 and
meets today’s lighting and
energy manage-ment standards.
The series is compatible with all
of today’s popular ceiling
systems. The Paralux V, PC|2
series is the solution for
computer environ-ments and
open office areas.
ORDERING INFORMATION
SAMPLE NUMBER: 2P5GAX-332S39MI-120V-EB81-U
HM= Hard
Metric
HR=Heat
(1)
Removal
HRDO=Heat
Removal
Damper Open
HRDC=Heat
Removal
Damper Closed
Width
2'=2' width
Blank=1' width or
20" width
P=Paralux Louver
5=5" Louver Depth
Trim Type
G=Grid/Lay-in – Standard
G or T=Concealed T
G or T=Slot Grid
F=Flange Trim
MZ=Modular Trim
Convertible Fixture Standard G (Grid)
Type-Fixtures can be field converted to
T-option or vice-versa.
adaptable with flanged or modular trims.
AX=Air Supply Floating Louver
X=Blank Side/Floating Louver - Non-Air Supply (Omit A)
AVX=Air Supply Floating Louver with Directional Air Vane (Add V)
PRODUCT INFORMATION FOR PARALUX V
Housing Lamp Louver Cell Number
Size Quantity Configuration* of Cells
1' x 2' 1 or 2 14 4
1' x 4' 1 or 2 19 9
2' x 2' 2 24 8
20" x 24" 2 24 8
20" x 48" 2 29 18
2' x 4' 2 29 18
*Example: 39= 3 rows of 9 (27 cells)
(2)
(3)
Fixture also
3 34 12
3 39 27
NOMINAL SIZE A B
1' x 2' 11-3/4" (298mm) 7" (178mm)
1' x 4' 11-3/4" (298mm) 7" (178mm)
2' x 2' 23-3/4" (603mm) 6-1/8" (156mm)
2' x 2' (8 cell) 23-3/4" (603mm) 6-3/4" (171mm)
2' x 4' 23-3/4" (603mm) 6-1/8" (156mm)
2' x 4' (18 cell) 23-3/4" (603mm) 6-5/8" (168mm)
20" x 24" 19-3/4" (502mm) 6-1/8" (156mm)
20" x 48" 19-3/4" (502mm) 7-3/8" (502mm)
Number
of Lamps
1, 2 or 3 lamps
(Not included)
Wattage (Length)
17=17W T8 (24")
U15/8=31W T8 (24")
BX40=40W Biaxial (24")
32=32W T8 (48")
Louver Color
S=Silver
Cell Configuration*
(See below for Louver Options)
Louver Finish
MI=Specular/Mirrored (Low Iridescent)
VDT=VDT Soft Semi-Specular/Haze
(Low Iridescent)
WB=White & Black Longitudinal Louver
Blades (Specular/Mirrored Cross Blades)
1x4 only
WBVDT=White & Black Longitudinal
Louver Blades (VDT Soft SemiSpecular/Haze Cross Blades) 1x4 only
WW
Wall Wash
(4)
Voltage
UNV=Universal
Voltage 120-277
347V=347 Volt
Options
GL=Single Element Fuse
GM=Double Element Fuse
WTR=White Reveal
Lamps - for lamps installed, see
lamp options table
Flex - for flex installed, see flex
ordering table
Emergency - for EM installed,
see EM options table
Ballast Type
Blank=Standard Magnetic Ballast (Biax & 20W)
= T5 Biax Electronic Instant Start. Total
EB5
No. of Ballast
1, 2 or 3
LE3=T12 Magnetic Energy Saving
=T12 Electronic Rapid Start.
EB2
No. of Ballast
1 or 2
ER8 = T8 Electronic Program Rapid Start. Total
No. of Ballast
1, 2 or 3
= T8 Electronic Instant Start. Total Harmonic
EB8
No. of Ballast
1, 2 or 3
/PLUS= T8 Electronic Instant Start. High
EB8
No. of
Ballast
1, 2 or 3
TEB5
No. of Ballast
1, 2 or 3
DLS=Digital Lighting System Dimming
(For complete details on generic or to specify
manufacturer’s ballast see pg. 469)
(5)
(4)
Harmonic Distortion < 20%
Harmonic Distortion < 10%
Distortion < 10%
Ballast Factor >1.13. Total Harmonic
Distortion < 20%
=T5 Biax Electronic Instant Start. Total
Harmonic Distortion < 10%
Options
(See Options
Section)
Packaging
U=Unit Pack
PAL=Job Pack,
out of carton
PALC=Job Pack,
in carton
COOPER LIGHTING
388
(1)
NOTES:
Integral end plate grid lock feature not available in heat removal.
housing only, appropriate shielding media assemblies must be utilized.
(5)
Not available when specifying emergencies, voltage must be specific.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting
Representative for availability and ordering information.
(2)
An EQ Grid Clip is recommended for all 9/16" ceiling systems.
(4)
Products also available in non-US voltages and frequencies for international markets.
(3)
Convertibility applies to
PERFORMANCE INFORMATION
COOPER LIGHTING - METALUX
PARALUX V
®
RP-1 1ST LEVEL
The concept of RP-1 is simple; by suppressing high angle brightness,
reflected glare will be avoided in the VDT screen at the normal tilt
angle. The 1st level sets the toughest standard.
The 1st level or preferred level states that the average luminance
brightness in the lengthwise (0°), crosswise (90°) and 45° lateral
planes should not exceed the following:
Candelas/M
850 Candela/sm at 55° from vertical 250 fl at 55° from vertical
350 Candela/sm at 65° from vertical 100 fl at 65° from vertical
175 Candela/sm at 75° from vertical 50 fl at 75° from vertical
175 Candela/sm at 85° from vertical 50 fl at 85° from vertical
2
Footlamberts (English)
RP-1 2ND LEVEL
The 2nd level is relaxed. It is suitable for areas where intermittent
computer work stations exist.
The 2nd level states that in no case shall the luminance brightness
exceed the following in the lengthwise (0°), crosswise (90°) and 45°
lateral planes:
Candelas/M
850 Candela/sm at 65° from vertical 250 fl at 65° from vertical
350 Candela/sm at 75° from vertical 100 fl at 75° from vertical
175 Candela/sm at 85° from vertical 50 fl at 85° from vertical
2
Footlamberts (English)
This view of the ceiling and room space illustrates the vertical plane
with vertical angles (light/dark grey area) from 0° to 90° in the 0°
(lengthwise) lateral plane. Notice the light grey areas. This is where
the Metalux Precision Parabolic bends the light into a confined cutoff-zone, 0° to 55°, (1st level). Now notice the dark grey areas. This is
where the light is restricted in the shielded zone, thus eliminating
high angle brightness (glare) in the VDT screen.
This view of the ceiling and room space illustrates the vertical plane
with vertical angles (light/dark grey area) from 0° to 90° in the 0°
(lengthwise) lateral plane. Notice the light grey areas. This is where
the Metalux Precision Parabolic bends the light into a confined cut-offzone, 0° to 65°, (2nd level). Now notice the dark grey areas. This is
where the light is restricted in the shielded zone, thus eliminating high
angle brightness (glare) in the VDT screen.
COOPER LIGHTING
389