Cooper Lighting Metalux 332 User Manual

Catalog #
Project
Comments
Prepared by
Date
SPECIFICATION FEATURES
09/23/2008 3:59:37 PM
Consult your representative for additional options and finishes.
Specifications and Dimensions subject to change without notice.
ADF020738
LAMP CONFIGURATIONS
MOUNTING DATA
DESCRIPTION
The EIM Series is an energy efficient family of industrials that feature
premium performance and durability. The industrial series incorporates
heavy duty, embossed, reflectors that precisely direct and effectively control
light. The EIM reflector is a unique design that was developed to prevent
debris accumulation in special applications. The versatile EIM Series can be
installed using various mounting methods and numerous options and
accessories are available.
The EIM Series can be utilized in simple task and area lighting to the most
demanding specialized industrial applications with environmental
requirements.
A ... Construction
Channel is code gauge prime cold
rolled steel. Die formed with deep
V-grooves for tong hanger. Die
formed channel connector assures
straight rows and continuity of
ground through set screws.
Lampholder mounting brackets are
easily inserted with snap-in action.
B ... Electrical*
Ballast are CBM/ETL Class "P" and
positively secured by mounting
bolts. Metal clad lampholders are
spring loaded for turret safety.
UL/CUL listed. Suitable for damp
locations.
C ... Finish
Multistage iron phosphate
pretreatment ensures maximum
bonding and rust inhibitor.
Lighting grade, baked white
enamel finish.
D ... Reflectors
Painted after fabrication. Die
formed code gauge steel. Deep
draw full width ribs formed with
one press stroke. Side flanges lend
strength with Downward turn.
Reflector design prevents lint, dust
and debris buildup. Easily cleaned.
Baked white enamel 13" width.
Four foot sections. Reflectors
secured by positive retaining
screw. Reflector aligners provided.
Standard with 20% uplight (EIM).
Closed top reflector (ECIM).
Optional Industrial fixtures are
available incorporating silver
technology enhancements.
(SilverLining) Consult Pre Sales
Technical Support.
EIM
240 232 340 332 440 432
4' INDUSTRIAL
2, 3 OR 4 LAMP
Environmental Heavy Duty
Industrial
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power
6-3/8"
[162mm]
13"
[330mm]
A B C
D
6-3/8"
[162mm]
13" [330mm]
6"
[152mm]
X
X=4-1/4" [108mm]
6-3/8"
[162mm]
13" [330mm]
Y
X
X=4-1/4" [108mm]
Y
Y=3"
[76mm]
6-3/8"
[162mm]
13" [330mm]
Y
X
X=4-1/4" [108mm]
Y
Y=2"
[51mm]
Y
Ground Screw Bump
7/8" [22mm] K.O. (5)
93" [2362mm]
88-3/4" [2254mm]
4-1/4"
[108mm]
5/16"
[8mm]
1-1/16"
[27mm]
99-1/2" [2527mm]
11/16" [17mm] x 1 K.O. (2)
7/32" [6mm] x 3/8" [10mm] K.O. (4)
79-1/2" [2019mm]
Ground Screw Bump
4-1/4"
[108mm]
5/16"
[8mm]
7/8" [22mm] K.O. (3)
11/16" [17mm] x 1 K.O. (2)
7/32" [6mm] x 3/8" [10mm] K.O. (4)
1-1/16"
[27mm]
41-1/2" [1054mm]
39" [991mm]
49-3/4" [1264mm]
EB Ballast & STD Lamps 240 (72) 232 (61) 340 (110) 332 (91) 440 (144) 432 (122)
ES Ballast & STD Lamps
240 (86) 232 (71) 340 (136) 332 (108) 440 (172) 432 (142) Luminaire Efficacy Rating
LER = FI-84 Catalog Number: EIM-232
Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.87
*Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements.
E N ER G Y DAT A
Input Watts:
COOPER LIGHT IN G - ME TA LU X
®
Specifications and Dimensions subject to change without notice.
PHOTOMETRICS
ORDERING INFORMATION
ACCESSORIES
SHIPPING INFORMATION
EIM
C a n de la
Angle Along II 45
o
Across
0 10 20 30 40 50 60 70 80 90
100 110 120 130 140 150 160 170 180
1406 1406 1406 1390 1391 1394 1322 1346 1358 1211 1257 1294 1062 1146 1272
870 1057 1093 645 833 728 398 501 590 164 213 147
9 37 23
34 77 63 109 22 49 193 74 26 267 175 102 336 291 217 393 314 336 433 401 337 456 454 454 459 459 459
C o e f
f i c ie nt s of Ut i l iz at io n
Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0 1 2 3 4 5 6 7 8 9
10
Z o n al L u me n Su m m ar y
Zone Lumens %Lamp %Fixture
0-30 0-40 0-60 0-90 90-180 0-180
||
EIM-232
Electronic Ballast
F32T8-SPX35 Lamps 2950 Lumens
Spacing criterion: (II) 1.3 x mounting height, () 1.4 x mounting height
Efficiency 96.3%
Test Report: EIM232.IES
LER = FI-84
Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.87
1124 19.1 19.8 1885 32.0 33.2 3544 60.1 62.4 4687 79.4 82.5
994 16.8 17.5
5680 96.3 100.0
111 111 111 111 106 106 106 106 98 98 98 90 90 90 83 83 83 79 100 96 91 88 96 92 88 85 85 82 79 78 76 73 72 70 68 65
91 83 76 70 87 79 73 68 73 68 64 68 64 60 62 59 56 53 82 72 64 58 79 69 62 56 64 58 53 59 54 50 55 51 47 44 75 64 55 49 72 61 53 47 57 50 45 52 47 42 48 44 40 37 69 56 48 41 66 54 46 40 50 44 38 47 41 36 43 38 35 32 63 51 42 36 60 49 41 35 45 38 33 42 36 32 39 34 30 28 59 46 37 31 56 44 36 31 41 34 29 38 32 28 36 30 27 24 54 41 33 28 52 40 32 27 37 31 26 35 29 25 33 27 24 22 51 38 30 25 48 37 29 24 34 28 23 32 26 22 30 25 21 19 47 35 27 22 45 34 27 22 32 25 21 30 24 20 28 23 19 17
Tandem Blank=4'
Length
8T=8' Length
Series EIM=
Apertured Reflector
ECIM=Closed
Top Reflector
SAMPLE NUMBER: EIM-232-120V-EB81 -U
Number of Lamps 2, 3 or 4
Lamps
(Not included)
Voltage
(1)
120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277
(2)
Lamp Spacing Blank=Standard Spacing N=Narrow Spacing for 2
Lamp Only (10% uplight)
Silver
(3)
Reflector SS=
Silver­Lining Reflector
Wattage (Length) 40=34/40W T12 (48") 32=32W T8 (48")
Options GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed
NOTES:
(1)
Products also available in non-US voltages and frequencies for international markets.
(2)
Not available when specifying emergencies, voltage must be specific.
(3)
Silver lining not available on fixtures with HO, VHO or PG.
Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
Ballast Type
(1)
EB8 =T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
EB8
/PLUS=T8 Electronic Instant Start.
High Ballast Factor >1.13. Total Harmonic Distortion < 20%
ER8
=T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
EB2
=T12 Electronic Rapid Start.
No. of Ballast 1, 2 or 3
No. of Ballast 1, 2 or 3
No. of Ballast 1, 2 or 3
No. of Ballast 1 or 2
Options RIF1=Radio Interference
Suppressor 6-3/18 SJT-C&P-515P=Cord & Plug (120V)
6-3/18 SJT-C&P­L715P=Cord & Plug (277V) PI/CPI=Plug-In Option TILW=Tandem In-Line
Wiring Option (Consult TILW Option Catalog Page) POX=Porlux Finish
(See options & accessories)
Packaging U=Unit Pack 4B=4 Bulk
(Order Separately)
A1B/Spacer-U=Spacer 1-1/2" to 2-1/2" from ceiling (Use 2 per fixture)
ATG-4=Tong Hanger (Use 2 per fixture)
SCF=Fixed Stem Set (Specify Length)
SCS=Swivel Stem Set (Specify Length)
SCA=Adjustable 48" Stem Set
AYC-Chain/Set-U=Chain Hanger Set (Use 1 set per fixture)
WG/DI-4FT-U1=Wire Guard
WGG/DI-4FT-U=Wire Gym Guard
DI2=Long Connector
CEP=Closed End Plate
(Note: Reflector will extend 1/4" past the end plate).
(Additional Accessories Available. See Options and Accessories Section).
EIM-232 15 lbs. 8TEIM-232 32 lbs. EIM-332 25 lbs. EIM-432 25 lbs.
Catalog No. Wt.
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
09/23/2008 3:59:37 PM
ADF020738
Loading...