Cooper Lighting Metalux 2PGAX User Manual

COOPER LIGHTING - METALUX
The Paralux IV series features
PARALUX IV
2PGAX SERIES
1' x 2', 1' x 4', 2' x 2', 2' x 4', 20" x 24", 20" x 48" Parabolic
recessed aesthetics and the latest in energy efficient technology. The luminaire incorporates a 4" precision cell louver into a nominal 6-1/2" deep para-contoured fixture housing. This combination creates a high comfort parabolic optical assembly for optimum performance. The Paralux IV series offers balanced illumination with reduced glare, increased VCP’s and excellent shielding. The series is compatible with all of today’s popular ceiling systems. The Paralux IV series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas.
®
DIMENSIONSDESCRIPTION
NOMINAL SIZE A B
1' x 2' 11-3/4" (298mm) 7-5/8" (194mm) 1' x 4' 11-3/4" (298mm) 7-5/8" (194mm) 2' x 2' 23-3/4" (603mm) 6-5/8" (168mm) 2' x 4' 23-3/4" (603mm) 6-5/8" (168mm) 20" x 24" 19-3/4" (502mm) 6-5/8" (168mm) 20" x 48" 19-3/4" (502mm) 6-5/8" (168mm)
1, 2, 3 or 4 Lamp Parabolic Louver
PARALUX IV RECESSED AIR SUPPLY TROFFER
• Equipped with energy saving ballasts/complies with federal energy efficiency standards
• Computer designed, precision cell louver technology
• Field convertible feature
• Self-locking spring loaded cam latches/T hinges
• Four auxiliary fixture end suspension points
• Interlocking tabs and screws secure end plates
• End plate grid-lock feature
• Efficient air handling options
• Hard metric configurations are available
ORDERING INFORMATION
SAMPLE NUMBER: 2PGAX-332S36I-120V-EB81-U
HM=Hard
Metric
HR=Heat
(1)
Removal HRDO=Heat Removal Damper Open HRDC=Heat Removal Damper Closed
Width 2'=2' width Blank=1' width
or 20" width
P=Paralux Louver
Trim Type G=Grid/Lay-in (Standard) G or T=Concealed T G or T=Slot Grid F=Flange Trim MZ=Modular Trim
Convertible Fixture Standard G (Grid)
Type-Fixtures can be field converted to T-option or vice-versa. adaptable with flanged or modular trims.
(1)
AX=Air Supply Floating Louver X=Blank Side/Floating Louver -
Non-Air Supply (Omit A) AVX=Air Supply Floating Louver with Directional Air Vane (Add V)
(2)
(3)
Fixture also
(5)
2048= 20" Width
x 48" Length 2024=20" Width x 24" Length
Number
(4)
of Lamps 1, 2, 3 or 4 lamps
(Not included)
Wattage (Length) U6T8=31W T8 (24") 17=17W T8 (24") U15/8=31W T8 (24") BX40=40W Biax (24") 32=32W T8 (48")
Louver Color S=Silver W=White
Cell Configuration*
(See below for Louver Options)
Louver Finish H=Semi-Specular/Haze (Gold only) I=Semi-Specular/Haze (Low Iridescent) Standard
(Silver Only)
MI=Specular/Mirrored (Low Iridescent) (Silver Only) P=Painted (White only)
Voltage UNV=Universal
Voltage 120-277
347V=347 Volt
Options GL=Single
Element Fuse GM=Double Element Fuse WTR=White Reveal Lamps - for lamps installed, see lamp options table Flex - for flex installed, see flex ordering table Emergency - for EM installed, see EM options table
Options
(6)
(See Options Section)
Ballast Type Blank=Standard
Magnetic Ballast (Biax & 20W)
LE3=T12 Magnetic Energy Saving EB8
EB8
ER8
EB5
TEB5
EB2
DLS=Digital Lighting System Dimming
(For complete details on generic or to specify manufacturer’s ballast see pg. 469)
(5)
= T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
No. of Ballast 1, 2 or 3
/PLUS= T8 Electronic Instant Start.
No. of Ballast 1, 2 or 3
No. of Ballast 1, 2 or 3
No. of Ballast 1, 2 or 3
No. of Ballast 1, 2 or 3
No. of Ballast 1 or 2
High Ballast Factor >1.13. Total Harmonic Distortion < 20%
= T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
= T5 Biax Electronic Instant Start.
Total Harmonic Distortion < 20%
=T5 Biax Electronic Instant Start.
Total Harmonic Distortion < 10%
=T12 Electronic Rapid Start.
Packaging U=Unit Pack PAL=Job Pack,
out of carton PALC=Job Pack, in carton
• Floating louver/black reveal
• For information on flanged fixture, including ceiling opening size, see Technical Section.
• UL/CUL Listed. Suitable for damp locations.
COOPER LIGHTING
390
PRODUCT INFORMATION FOR PARALUX IV
Housing Louver Cell Number
Size Configuration* of Cells
1' x 2' 13, 14, 23, 24 3, 4, 6, 8
1' x 4' 16, 18, 19, 26, 28, 29 6, 8, 9, 12, 16, 18
2' x 2' 22, 23, 24, 33, 34, 44 4, 6, 8, 9, 12, 16
20" x 24" 23, 24, 33, 34 6, 8, 9, 12
20" x 48" 26, 28, 29, 36, 38, 39, 46, 48, 49 12, 16, 18, 18, 24, 27, 24, 32, 36
2' x 4' 26, 28, 29, 36, 38, 46, 48, 49 12, 16, 18, 18, 24, 24, 32, 36
*Example: 36= 3 rows of 6 (18 cells)
(1)
NOTES:
Integral end plate grid lock feature not available in heat removal. housing only, appropriate shielding media assemblies must be utilized. frequencies for international markets.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
(6)
Not available when specifying emergencies, voltage must be specific.
(2)
An EQ Grid Clip is recommended for all 9/16" ceiling systems.
(4)
Standard off-center ballast on 3-lamp fixtures.
(5)
Products also available in non-US voltages and
(3)
Convertibility applies to
Loading...