Cooper Lighting Metalux 2P5GAX SERIES, Metalux 388 Specification Sheet

Page 1
PARALUX V
388
COOPER LIGHTING
• Equipped with energy saving ballast/complies with federal energy efficiency standards
• Louver designed to eliminate objectionable glare in the VDT screen
• Low iridescent louver minimizes iridescence
• Field convertible feature
• Floating louver/black reveal
• Efficient air handling options
DLS Dimming Ballasts are
available
• End plate grid-lock feature
(1)
• For information on flanged fixture, including ceiling opening size, see Technical Section.
• UL/CUL Listed. Suitable for damp locations.
2P5GAX SERIES
1' x 2', 1' x 4', 2' x 2', 2' x 4', 20" x 24" or 20" x 48" Parabolic 1, 2 or 3 Lamp Parabolic Louver
PARALUX V RECESSED AIR SUPPLY PRECISION CUT-OFF TROFFER
DIMENSIONS
DESCRIPTION
The Paralux V series features a proprietary “Total Light Control System” that has been designed to eliminate glare reflections in VDT screens by suppressing high angle brightness. Meets today’s lighting standards. The luminaire incorporates a precision cut-off parabolic louver in a para­contoured fixture housing. This system complies with RP-1 and meets today’s lighting and energy manage-ment standards. The series is compatible with all of today’s popular ceiling systems. The Paralux V, PC|2 series is the solution for computer environ-ments and open office areas.
NOMINAL SIZE A B
1' x 2' 11-3/4" (298mm) 7" (178mm) 1' x 4' 11-3/4" (298mm) 7" (178mm) 2' x 2' 23-3/4" (603mm) 6-1/8" (156mm) 2' x 2' (8 cell) 23-3/4" (603mm) 6-3/4" (171mm) 2' x 4' 23-3/4" (603mm) 6-1/8" (156mm) 2' x 4' (18 cell) 23-3/4" (603mm) 6-5/8" (168mm) 20" x 24" 19-3/4" (502mm) 6-1/8" (156mm) 20" x 48" 19-3/4" (502mm) 7-3/8" (502mm)
ORDERING INFORMATION
SAMPLE NUMBER: 2P5GAX-332S39MI-120V-EB81-U
Options
(See Options Section)
Number of Lamps 1, 2 or 3 lamps
(Not included)
Wattage (Length) 17=17W T8 (24") U15/8=31W T8 (24") BX40=40W Biaxial (24") 32=32W T8 (48")
Voltage
(4)
UNV=Universal
Voltage 120-277
(5)
347V=347 Volt
Louver Color S=Silver
Cell Configuration*
(See below for Louver Options)
HR=Heat Removal
(1)
HRDO=Heat
Removal Damper Open HRDC=Heat Removal Damper Closed
P=Paralux Louver
5=5" Louver Depth
Width 2'=2' width Blank=1' width or
20" width
Trim Type G=Grid/Lay-in – Standard G or T=Concealed T G or T=Slot Grid
(2)
F=Flange Trim MZ=Modular Trim
Convertible Fixture Standard G (Grid)
Type-Fixtures can be field converted to T-option or vice-versa.
(3)
Fixture also
adaptable with flanged or modular trims.
AX=Air Supply Floating Louver X=Blank Side/Floating Louver - Non-Air Supply (Omit A) AVX=Air Supply Floating Louver with Directional Air Vane (Add V)
NOTES:
(1)
Integral end plate grid lock feature not available in heat removal.
(2)
An EQ Grid Clip is recommended for all 9/16" ceiling systems.
(3)
Convertibility applies to
housing only, appropriate shielding media assemblies must be utilized.
(4)
Products also available in non-US voltages and frequencies for international markets.
(5)
Not available when specifying emergencies, voltage must be specific.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
HM= Hard Metric
WW
Wall Wash
Louver Finish MI=Specular/Mirrored (Low Iridescent) VDT=VDT Soft Semi-Specular/Haze
(Low Iridescent) WB=White & Black Longitudinal Louver Blades (Specular/Mirrored Cross Blades) 1x4 only WBVDT=White & Black Longitudinal Louver Blades (VDT Soft Semi­Specular/Haze Cross Blades) 1x4 only
Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Lamps - for lamps installed, see
lamp options table Flex - for flex installed, see flex ordering table Emergency - for EM installed, see EM options table
Housing Lamp Louver Cell Number
Size Quantity Configuration* of Cells
1' x 2' 1 or 2 14 4
1' x 4' 1 or 2 19 9
2' x 2' 2 24 8
3 34 12
20" x 24" 2 24 8
20" x 48" 2 29 18
2' x 4' 2 29 18
3 39 27
*Example: 39= 3 rows of 9 (27 cells)
PRODUCT INFORMATION FOR PARALUX V
Ballast Type
(4)
Blank=Standard Magnetic Ballast (Biax & 20W) EB5
= T5 Biax Electronic Instant Start. Total
Harmonic Distortion < 20%
LE3=T12 Magnetic Energy Saving EB2
=T12 Electronic Rapid Start.
ER8 = T8 Electronic Program Rapid Start. Total
Harmonic Distortion < 10%
EB8
= T8 Electronic Instant Start. Total Harmonic
Distortion < 10%
EB8
/PLUS= T8 Electronic Instant Start. High
Ballast Factor >1.13. Total Harmonic Distortion < 20%
TEB5
=T5 Biax Electronic Instant Start. Total
Harmonic Distortion < 10%
DLS=Digital Lighting System Dimming
(For complete details on generic or to specify manufacturer’s ballast see pg. 469)
No. of Ballast 1, 2 or 3
No. of Ballast 1, 2 or 3
No. of Ballast 1, 2 or 3
No. of Ballast 1, 2 or 3
No. of Ballast 1, 2 or 3
No. of Ballast 1 or 2
Packaging U=Unit Pack PAL=Job Pack,
out of carton PALC=Job Pack, in carton
COOPER LIGHTING - METALUX
®
Page 2
PARALUX V
389
COOPER LIGHTING
PERFORMANCE INFORMATION
RP-1 1ST LEVEL
The concept of RP-1 is simple; by suppressing high angle brightness, reflected glare will be avoided in the VDT screen at the normal tilt angle. The 1st level sets the toughest standard.
The 1st level or preferred level states that the average luminance brightness in the lengthwise (0°), crosswise (90°) and 45° lateral planes should not exceed the following:
Candelas/M
2
Footlamberts (English)
850 Candela/sm at 55° from vertical 250 fl at 55° from vertical 350 Candela/sm at 65° from vertical 100 fl at 65° from vertical 175 Candela/sm at 75° from vertical 50 fl at 75° from vertical 175 Candela/sm at 85° from vertical 50 fl at 85° from vertical
This view of the ceiling and room space illustrates the vertical plane with vertical angles (light/dark grey area) from 0° to 90° in the 0° (lengthwise) lateral plane. Notice the light grey areas. This is where the Metalux Precision Parabolic bends the light into a confined cut­off-zone, 0° to 55°, (1st level). Now notice the dark grey areas. This is where the light is restricted in the shielded zone, thus eliminating high angle brightness (glare) in the VDT screen.
RP-1 2ND LEVEL
The 2nd level is relaxed. It is suitable for areas where intermittent computer work stations exist.
The 2nd level states that in no case shall the luminance brightness exceed the following in the lengthwise (0°), crosswise (90°) and 45° lateral planes:
Candelas/M
2
Footlamberts (English)
850 Candela/sm at 65° from vertical 250 fl at 65° from vertical 350 Candela/sm at 75° from vertical 100 fl at 75° from vertical 175 Candela/sm at 85° from vertical 50 fl at 85° from vertical
This view of the ceiling and room space illustrates the vertical plane with vertical angles (light/dark grey area) from 0° to 90° in the 0° (lengthwise) lateral plane. Notice the light grey areas. This is where the Metalux Precision Parabolic bends the light into a confined cut-off­zone, 0° to 65°, (2nd level). Now notice the dark grey areas. This is where the light is restricted in the shielded zone, thus eliminating high angle brightness (glare) in the VDT screen.
COOPER LIGHTING - METALUX
®