Cooper Lighting Metalux 2EP3GAX Series Specification Sheet

Page 1
PARALUX III
391
COOPER LIGHTING
• Equipped with energy saving ballasts/complies with federal energy efficiency standards
• Field convertible feature
• Self locking spring loaded cam latches/ T hinges
• Four auxiliary fixture end suspension points provided
• Interlocking tabs and screws secure end plates
• End plate grid-lock feature
(1)
• Efficient air handling options
DLS Dimming Ballasts are available
• Floating louver/black reveal
• For information on flanged fixture, including ceiling opening size, see Technical Section.
• UL/CUL Listed. Suitable for damp locations.
2EP3GAX SERIES
1' x 4', 2' x 2', 2' x 4',
20" x 24" or
20" x 48" Parabolic
1, 2, 3 or 4 Lamp Parabolic Louver
PARALUX III
RECESSED STATIC OR
AIR SUPPLY TROFFER
DESCRIPTION
The Paralux III series features recessed aesthetics and the latest in energy efficient technology. The luminaire incorporates a 3" precision cell louver into a nominal 5-1/2" deep para-contoured fixture housing. This combination creates a total high performance parabolic optical assembly for optimum performance. The Paralux III series offers balanced illumination with reduced glare, increased VCP’s and excellent shielding. The series is compatible with all of today’s popular ceiling systems. The Paralux III series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas.
DIMENSIONS
NOMINAL SIZE A B
1' x 4' 11-3/4" (298mm) 6-5/8" (168mm) 1' x 4' (OU) 11-3/4" (298mm) 8-1/4" (210mm) 2' x 2' 23-3/4" (603mm) 5-5/8" (143mm) 2' x 4' 23-3/4" (603mm) 5-5/8" (143mm) 20" x 24" 19-3/4" (502mm) 5-5/8" (143mm) 20" x 48" 19-3/4" (502mm) 5-5/8" (143mm)
ORDERING INFORMATION
SAMPLE NUMBER: 2EP3GAX-332S36I-120V-EB81-U
Housing Louver Cell Number
Size Configuration* of Cells
1' x 2' 13, 14, 23, 24 3, 4, 6, 8
1' x 4' 16, 18, 26, 28 6, 8, 12, 16
2' x 2' 23, 33, 34, 44 6, 9, 12, 16
20" x 24" 23, 24, 33, 34 6, 8, 9, 12
20" x 48" 26, 36, 38 12, 18, 24
2' x 4' 26, 28, 36, 38, 46, 48 12, 16, 18, 24, 24, 32
*Example: 36= 3 rows of 6 (18 cells)
PRODUCT INFORMATION FOR PARALUX III
Options
(See Options Section)
Number of Lamps
(4)
1, 2, 3 or 4 lamps
(Not included)
Wattage (Length) U6T8=31W T8 (24") 17=17W T8 (24") U15/8=31W T8 (24") BX40=40W Biax (24") 32=32W T8 (48")
2048= 20" Width
x 48" Length 2024=20" Width x 24" Length
Voltage
(5)
120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal
Voltage 120-277
(6)
Louver Color S=Silver W=White
Cell Configuration*
(See below for Louver Options)
Louver Finish H=Semi-Specular/Haze (Gold only) I=Semi-Specular/Haze (Low Iridescent) Standard
(Silver Only)
MI=Specular/Mirrored (Low Iridescent) (Silver Only) P=Painted (White only)
HR=Heat
Removal
(1)
HRDO=Heat
Removal Damper Open HRDC=Heat Removal Damper Closed
EP=Paralux Louver
Width 2'=2' width Blank=1' width
or 20" width
Trim Type G=Grid/Lay-in (Standard) G or T=Concealed T G or T=Slot Grid
(2)
F=Flange Trim MZ=Modular Trim
Convertible Fixture
(3)
Standard G (Grid) Type-Fixtures can be field converted to T-option or vice-versa. Fixture also adaptable with flanged or modular trims.
AX=Air Supply Floating Louver X=Blank Side/Floating Louver -
Non-Air Supply (Omit A) AVX=Air Supply Floating Louver with Directional Air Vane (Add V)
HM=Hard Metric
Options GL=Single
Element Fuse GM=Double Element Fuse WTR=White Reveal Lamps - for lamps installed, see lamp options table Flex - for flex installed, see flex ordering table Emergency - for EM installed, see EM options table
3=3" Louver Depth
Packaging U=Unit Pack PAL=Job Pack,
out of carton PALC=Job Pack, in carton
NOTES:
(1)
Integral end plate grid lock feature not available in heat removal.
(2)
An EQ Grid Clip is recommended for all 9/16" ceiling systems.
(3)
Convertibility applies to
housing only, appropriate shielding media assemblies must be utilized.
(4)
Standard off-center ballast on 3-lamp fixtures.
(5)
Products also available in non-US voltages and
frequencies for international markets.
(6)
Not available when specifying emergencies, voltage must be specific.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
Ballast Type
(5)
Blank=Standard Magnetic
Ballast (Biax & 20W)
LE3=T12 Magnetic Energy Saving EB8
= T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
EB8
/PLUS= T8 Electronic Instant Start.
High Ballast Factor >1.13. Total Harmonic Distortion < 20%
ER8
= T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
EB5
= T5 Biax Electronic Instant Start.
Total Harmonic Distortion < 20%
TEB5
=T5 Biax Electronic Instant Start.
Total Harmonic Distortion < 10%
EB2
=T12 Electronic Rapid Start.
DLS=Digital Lighting System Dimming
(For complete details on generic or to specify manufacturer’s ballast see pg. 469)
No. of Ballast 1, 2 or 3
No. of Ballast 1, 2 or 3
No. of Ballast 1, 2 or 3
No. of Ballast 1, 2 or 3
No. of Ballast 1, 2 or 3
No. of Ballast 1 or 2