COOPER LIGHTING - METALUX
PARALUX III
®
DIMENSIONS
NOMINAL SIZE A B
1' x 4' 11-3/4" (298mm) 6-5/8" (168mm)
1' x 4' (OU) 11-3/4" (298mm) 8-1/4" (210mm)
2' x 2' 23-3/4" (603mm) 5-5/8" (143mm)
2' x 4' 23-3/4" (603mm) 5-5/8" (143mm)
20" x 24" 19-3/4" (502mm) 5-5/8" (143mm)
20" x 48" 19-3/4" (502mm) 5-5/8" (143mm)
ORDERING INFORMATION
SAMPLE NUMBER: 2EP3GAX-332S36I-120V-EB81-U
HM=Hard
Metric
HR=Heat
(1)
Removal
HRDO=Heat
Removal
Damper Open
HRDC=Heat
Removal
Damper Closed
Width
2'=2' width
Blank=1' width
or 20" width
EP=Paralux Louver
3=3" Louver Depth
Trim Type
G=Grid/Lay-in (Standard)
G or T=Concealed T
G or T=Slot Grid
F=Flange Trim
MZ=Modular Trim
Convertible Fixture
Type-Fixtures can be field converted to
T-option or vice-versa. Fixture also
adaptable with flanged or modular trims.
AX=Air Supply Floating Louver
X=Blank Side/Floating Louver -
Non-Air Supply (Omit A)
AVX=Air Supply Floating Louver
with Directional Air Vane (Add V)
(2)
(3)
Standard G (Grid)
2048= 20" Width
x 48" Length
2024=20" Width
x 24" Length
Number
(4)
of Lamps
1, 2, 3 or 4 lamps
(Not included)
Wattage (Length)
U6T8=31W T8 (24")
17=17W T8 (24")
U15/8=31W T8 (24")
BX40=40W Biax (24")
32=32W T8 (48")
Louver Color
S=Silver
W=White
Cell Configuration*
(See below for Louver Options)
Louver Finish
H=Semi-Specular/Haze (Gold only)
I=Semi-Specular/Haze (Low Iridescent) Standard
(Silver Only)
MI=Specular/Mirrored (Low Iridescent) (Silver Only)
P=Painted (White only)
Voltage
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal
Voltage 120-277
Options
GL=Single
Element Fuse
GM=Double
Element Fuse
WTR=White
Reveal
Lamps - for lamps
installed, see lamp
options table
Flex - for flex
installed, see flex
ordering table
Emergency - for
EM installed, see
EM options table
DESCRIPTION
The Paralux III series features
recessed aesthetics and the
latest in energy efficient
technology. The luminaire
incorporates a 3" precision cell
louver into a nominal 5-1/2" deep
para-contoured fixture housing.
This combination creates a total
high performance parabolic
optical assembly for optimum
performance. The Paralux III
series offers balanced
illumination with reduced glare,
2EP3GAX SERIES
increased VCP’s and excellent
shielding. The series is
compatible with all of today’s
popular ceiling systems. The
Paralux III series is an excellent
1' x 4', 2' x 2', 2' x 4',
20" x 24" or
20" x 48" Parabolic
choice for commercial office
spaces, schools, hospitals or
retail merchandising areas.
(5)
Ballast Type
(6)
Blank=Standard Magnetic
Ballast (Biax & 20W)
LE3=T12 Magnetic Energy Saving
EB8
No. of Ballast
1, 2 or 3
EB8
No. of
Ballast
1, 2 or 3
ER8
No. of Ballast
1, 2 or 3
EB5
No. of Ballast
1, 2 or 3
TEB5
No. of Ballast
1, 2 or 3
EB2
No. of Ballast
1 or 2
DLS=Digital Lighting System Dimming
(For complete details on generic or to specify
manufacturer’s ballast see pg. 469)
Options
(See Options
Section)
(5)
= T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
/PLUS= T8 Electronic Instant Start.
High Ballast Factor >1.13. Total
Harmonic Distortion < 20%
= T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
= T5 Biax Electronic Instant Start.
Total Harmonic Distortion < 20%
=T5 Biax Electronic Instant Start.
Total Harmonic Distortion < 10%
=T12 Electronic Rapid Start.
Packaging
U=Unit Pack
PAL=Job Pack,
out of carton
PALC=Job Pack,
in carton
• Equipped with energy
• Computer designed,
• Field convertible feature
• Self locking spring loaded
• Four auxiliary fixture end
• Interlocking tabs and
• End plate grid-lock
• Efficient air handling
• DLS Dimming Ballasts are
1, 2, 3 or 4 Lamp
Parabolic Louver
PARALUX III
RECESSED STATIC OR
AIR SUPPLY TROFFER
saving ballasts/complies
with federal energy
efficiency standards
precision cell louver
technology
cam latches/ T hinges
suspension points provided
screws secure end plates
(1)
feature
options
available
PRODUCT INFORMATION FOR PARALUX III
Housing Louver Cell Number
Size Configuration* of Cells
1' x 2' 13, 14, 23, 24 3, 4, 6, 8
1' x 4' 16, 18, 26, 28 6, 8, 12, 16
2' x 2' 23, 33, 34, 44 6, 9, 12, 16
20" x 24" 23, 24, 33, 34 6, 8, 9, 12
20" x 48" 26, 36, 38 12, 18, 24
2' x 4' 26, 28, 36, 38, 46, 48 12, 16, 18, 24, 24, 32
*Example: 36= 3 rows of 6 (18 cells)
(1)
NOTES:
Integral end plate grid lock feature not available in heat removal.
housing only, appropriate shielding media assemblies must be utilized.
frequencies for international markets.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting
Representative for availability and ordering information.
(6)
Not available when specifying emergencies, voltage must be specific.
(2)
An EQ Grid Clip is recommended for all 9/16" ceiling systems.
(4)
Standard off-center ballast on 3-lamp fixtures.
(5)
Products also available in non-US voltages and
(3)
Convertibility applies to
• Floating louver/black reveal
• For information on flanged
fixture, including ceiling
opening size, see Technical
Section.
• UL/CUL Listed. Suitable for
damp locations.
COOPER LIGHTING
391