Cooper Lighting Metalux 2EP3GAX User Manual

COOPER LIGHTING - METALUX
PARALUX III
®
DIMENSIONS
NOMINAL SIZE A B
1' x 4' 11-3/4" (298mm) 6-5/8" (168mm) 1' x 4' (OU) 11-3/4" (298mm) 8-1/4" (210mm) 2' x 2' 23-3/4" (603mm) 5-5/8" (143mm) 2' x 4' 23-3/4" (603mm) 5-5/8" (143mm) 20" x 24" 19-3/4" (502mm) 5-5/8" (143mm) 20" x 48" 19-3/4" (502mm) 5-5/8" (143mm)
ORDERING INFORMATION
SAMPLE NUMBER: 2EP3GAX-332S36I-120V-EB81-U
HM=Hard
Metric
HR=Heat
(1)
Removal HRDO=Heat Removal Damper Open HRDC=Heat Removal Damper Closed
Width 2'=2' width Blank=1' width
or 20" width
EP=Paralux Louver
3=3" Louver Depth
Trim Type G=Grid/Lay-in (Standard) G or T=Concealed T G or T=Slot Grid F=Flange Trim MZ=Modular Trim
Convertible Fixture
Type-Fixtures can be field converted to T-option or vice-versa. Fixture also adaptable with flanged or modular trims.
AX=Air Supply Floating Louver X=Blank Side/Floating Louver -
Non-Air Supply (Omit A) AVX=Air Supply Floating Louver with Directional Air Vane (Add V)
(2)
(3)
Standard G (Grid)
2048= 20" Width x 48" Length 2024=20" Width x 24" Length
Number
(4)
of Lamps 1, 2, 3 or 4 lamps
(Not included)
Wattage (Length) U6T8=31W T8 (24") 17=17W T8 (24") U15/8=31W T8 (24") BX40=40W Biax (24") 32=32W T8 (48")
Louver Color S=Silver W=White
Cell Configuration*
(See below for Louver Options)
Louver Finish H=Semi-Specular/Haze (Gold only) I=Semi-Specular/Haze (Low Iridescent) Standard
(Silver Only)
MI=Specular/Mirrored (Low Iridescent) (Silver Only) P=Painted (White only)
Voltage 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal
Voltage 120-277
Options GL=Single
Element Fuse GM=Double Element Fuse WTR=White Reveal Lamps - for lamps installed, see lamp options table Flex - for flex installed, see flex ordering table Emergency - for EM installed, see EM options table
DESCRIPTION
The Paralux III series features recessed aesthetics and the latest in energy efficient technology. The luminaire incorporates a 3" precision cell louver into a nominal 5-1/2" deep para-contoured fixture housing. This combination creates a total high performance parabolic optical assembly for optimum performance. The Paralux III series offers balanced illumination with reduced glare,
2EP3GAX SERIES
increased VCP’s and excellent shielding. The series is compatible with all of today’s popular ceiling systems. The Paralux III series is an excellent
1' x 4', 2' x 2', 2' x 4',
20" x 24" or
20" x 48" Parabolic
choice for commercial office spaces, schools, hospitals or retail merchandising areas.
(5)
Ballast Type
(6)
Blank=Standard Magnetic
Ballast (Biax & 20W)
LE3=T12 Magnetic Energy Saving EB8
No. of Ballast 1, 2 or 3
EB8
No. of Ballast 1, 2 or 3
ER8
No. of Ballast 1, 2 or 3
EB5
No. of Ballast 1, 2 or 3
TEB5
No. of Ballast 1, 2 or 3
EB2
No. of Ballast 1 or 2
DLS=Digital Lighting System Dimming
(For complete details on generic or to specify manufacturer’s ballast see pg. 469)
Options
(See Options Section)
(5)
= T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
/PLUS= T8 Electronic Instant Start.
High Ballast Factor >1.13. Total Harmonic Distortion < 20%
= T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
= T5 Biax Electronic Instant Start.
Total Harmonic Distortion < 20%
=T5 Biax Electronic Instant Start.
Total Harmonic Distortion < 10%
=T12 Electronic Rapid Start.
Packaging U=Unit Pack PAL=Job Pack,
out of carton PALC=Job Pack, in carton
• Equipped with energy
• Computer designed,
• Field convertible feature
• Self locking spring loaded
• Four auxiliary fixture end
• Interlocking tabs and
• End plate grid-lock
• Efficient air handling
DLS Dimming Ballasts are
1, 2, 3 or 4 Lamp Parabolic Louver
PARALUX III
RECESSED STATIC OR
AIR SUPPLY TROFFER
saving ballasts/complies with federal energy efficiency standards
cam latches/ T hinges
suspension points provided
screws secure end plates
(1)
feature
options
available
PRODUCT INFORMATION FOR PARALUX III
Housing Louver Cell Number
Size Configuration* of Cells
1' x 2' 13, 14, 23, 24 3, 4, 6, 8
1' x 4' 16, 18, 26, 28 6, 8, 12, 16
2' x 2' 23, 33, 34, 44 6, 9, 12, 16
20" x 24" 23, 24, 33, 34 6, 8, 9, 12
20" x 48" 26, 36, 38 12, 18, 24
2' x 4' 26, 28, 36, 38, 46, 48 12, 16, 18, 24, 24, 32
*Example: 36= 3 rows of 6 (18 cells)
(1)
NOTES:
Integral end plate grid lock feature not available in heat removal. housing only, appropriate shielding media assemblies must be utilized. frequencies for international markets.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
(6)
Not available when specifying emergencies, voltage must be specific.
(2)
An EQ Grid Clip is recommended for all 9/16" ceiling systems.
(4)
Standard off-center ballast on 3-lamp fixtures.
(5)
Products also available in non-US voltages and
(3)
Convertibility applies to
• Floating louver/black reveal
• For information on flanged fixture, including ceiling opening size, see Technical Section.
• UL/CUL Listed. Suitable for damp locations.
COOPER LIGHTING
391
Loading...