SPECIFICATION FEATURES
09/17/2008 4:50:12 PM
Consult your representative for additional options and finishes.
Specifications and Dimensions subject to change without notice.
ADF020737
LAMP CONFIGURATIONS
MOUNTING DATA
DESCRIPTION
The EIVM Series is an energy efficient family of industrials that feature
premium performance and durability. The industrial series incorporates
heavy duty, embossed, reflectors that precisely direct and effectively control
light. The EIVM reflector is a unique design that was developed to prevent
debris accumulation in special applications. The special deep center "V"
reflector provides 30° crosswise shielding to minimize glare. The versatile
EIVM Series can be installed using various mounting methods and
numerous options and accessories are available. The EIVM Series can be
utilized in simple task and area lighting to the most demanding specialized
industrial applications with environmental requirements.
A ... Construction
Channel is code gauge prime cold
rolled steel. Die formed with deep
V-grooves for tong hanger. Die
formed channel connector assures
straight rows and continuity of
ground through set screws.
Lampholder mounting brackets are
easily inserted with snap-in action.
B ... Electrical*
Ballast are CBM/ETL Class "P" and
positively secured by mounting
bolts. Metal clad lampholders are
spring loaded for turret safety.
UL/CUL listed. Suitable for damp
locations.
C ... Finish
Multistage iron phosphate
pretreatment ensures maximum
bonding and rust inhibitor.
Lighting grade, baked white
enamel finish.
D ... Reflectors
Painted after fabrication. Die
formed code gauge steel. Deep
draw full width ribs formed with
one press stroke. Side flanges lend
strength with downward turn.
Reflector design prevents lint, dust
and debris buildup. Easily cleaned.
Baked white enamel 13" width.
Four foot sections. Reflector Center
"V" provides 30° crosswise
shielding and reduces glare.
Reflector and Center "V" retained
by positive mounting bolt.
Reflector aligners provided.
Standard with 20% uplight (EIVM).
Closed top reflector (ECIVM).
EIVM
248PG
296PG 248VHO 296VHO
4' OR 8' INDUSTRIAL
2 LAMP
POWER GROOVE, 1500 MA
VERY HIGH OUTPUT,
1500MA
Environmental Heavy Duty
Industrial
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power
6-3/8"
[162mm]
13"
[330mm]
A B C
D
STD Ballast & STD Lamps
248PG (242) 248VHO (242) 296PG (440) 296VHO (440) Luminaire Efficacy Rating
LER = FI-60 Catalog Number: EIVM-296PG
Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.0 0
*Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements.
E N ER G Y D AT A
Input Watts:
6-3/8"
[162mm]
13" [330mm]
6"
[152mm]
X
X=4-1/4" [108mm]
Ground Screw Bump
7/8" [22mm] K.O. (3)
11/16" [17mm] x 1 K.O. (2)
7/32" [6mm] x 3/8" [10mm] K.O. (4)
4-1/4"
[108mm]
5/16"
[8mm]
1-1/16"
[27mm]
41-1/2" [1054mm]
37-1/4" [946mm]
48" [1219mm]
4-1/4"
[108mm]
5/16"
[8mm]
7/8" [22mm] K.O. (5)
11/16" [17mm] x 1 K.O. (2)
7/32" [6mm] x 3/8" [10mm] K.O. (4)
Ground Screw Bump
1-1/16"
[27mm]
89-1/2" [2273mm]
85-1/4" [2165mm]
96" [2438mm]
7/8" [22mm] K.O. (5)
76" [1930mm]
COOPER LIGHTIN G - ME TA LU X
®
Specifications and Dimensions subject to change without notice.
PHOTOMETRICS
ORDERING INFORMATION
ACCESSORIES (Order Separately)
SHIPPING INFORMATION
EIVM
C a n d e l a
Angle Along II 45
o
Across
0 10 20 30 40 50 60 70 80 90
100 110 120 130 140 150 160 170 180
7285 7285 7285 7217 7205 7269 6885 6923 6944 6347 6364 6322 5631 5584 5605 4726 4650 4052 3634 3037 2235 2397 1327 956 1075 478 486
36 122 142 271 227 218 698 418 419
1111 689 636 1500 1031 899 1827 1345 1230 2085 1632 1507 2270 2171 1923 2371 2357 2384 2396 2396 2396
C o e ff i c i e n t s of U t i l i z a t i o n
Effective floor cavity r eflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0
1
2
3
4
5
6
7
8
9
10
Z o n a l Lu m e n Su m m a r y
Zone Lumens %Lamp %Fixture
0-30 0-40 0-60 0-90 90-180 0-180
||
EIVM-296PG
Energy Saving Ballast
F96PG17/CW Lamps 15300 Lumens
Spacing criterion: (II) 1.3 x mounting height, ( ) 1.3 x mounting height
Efficiency 86.0%
Test Report: EIVM296PG.IES
LER = FI-60
Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.00
5776
18.9 22.0
9545
31.2 36.3
16903
55.2 64.2
20600
67.3 78.3
5713 18.7 21.7
26313 86.0 100.0
98 98 98 98 93 93 93 93 85 85 85 78 78 78 71 71 71 67 90 86 82 79 85 82 79 76 75 73 70 69 67 65 63 61 60 57 82 75 70 65 78 72 67 63 66 62 59 60 57 54 55 53 51 48 75 66 59 54 71 63 57 53 58 53 49 53 49 46 49 46 43 40 68 59 51 46 65 56 50 45 52 46 42 48 43 40 44 40 37 35 63 52 45 39 60 50 43 38 46 41 36 43 38 34 39 35 32 30 58 47 40 34 55 45 38 33 42 36 32 39 34 30 36 32 28 26 54 42 35 30 51 41 34 29 38 32 28 35 30 27 32 28 25 23 50 39 32 27 47 37 31 26 35 29 25 32 27 24 30 26 22 21 46 35 29 24 44 34 28 23 32 26 22 30 25 21 57 23 20 19 43 33 26 22 41 31 25 21 29 24 20 27 23 19 25 21 18 17
SAMPLE NUMBER: EIVM-296PG-120V -EB81- U
Number of Lamps 2 Lamps
(Not included)
Wattage (Length) 48VHO=110W (48") VHO 96VHO=185/215W (96") VHO 96PG=182/215W (96") PG
Voltage
(1)
120V=120 Volt 277V=277 Volt 347V=347 Volt
Options GL=Single Element Fuse GM=Double Element Fuse Emergency=EM Installed
Options RIF1=Radio Interference
Suppressor 6-3/18 SJT-C&P-515P=Cord & Plug (120V)
6-3/18 SJT-C&P­L715P=Cord & Plug (277V) PI/CPI=Plug-In Option TILW=Tandem In-Line
Wiring Option (Consult TILW Option Catalog Page) POX=Porlux Finish
(See options & accessories)
Packaging U=Unit Pack 4B=4 Bulk
NOTES:
(1)
Products also available in non-US voltages and frequencies for international markets.
(2)
Silver lining not available on fixtures with HO, VHO or PG.
Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
Ballast Type
(1)
EB8 = T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
EB8
/PLUS=T8 Electronic Instant Start.
High Ballast Factor >1.13. Total Harmonic Distortion < 20%
ER8
=T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
EB2
=T12 Electronic Rapid Start.
No. of Ballast 1, 2 or 3
No. of Ballast 1, 2 or 3
No. of Ballast 1, 2 or 3
No. of Ballast 1 or 2
Tandem Blank=4' Length 8T=8' Length
Series EIVM=Apertured
Reflector EICM=Closed Top Reflector
A1B/Spacer -U=Spacer 1-1/2" to 2-1/2" from ceiling (Use 2 per fixture)
ATG-4=Tong Hanger (Use 2 per fixture)
SCF=Fixed Stem Set (Specify Length)
SCS=Swivel Stem Set (Specify Length)
SCA=Adjustable 48" Stem Set
AYC-Chain/Set-U =Chain Hanger Set (Use 1 set per fixture)
WG/DI-4FT-U1=Wire Guard
WGG/DI-4FT-U=Wire Gym Guard
DI2=Long Connector
CEP=Closed End Plate
(Note: Reflector will extend 1/4" past the end plate).
(Additional Accessories Available. See Options and Accessories Section).
EIVM-248PG
1
40 lbs.
EIVM-296PG
1
72 lbs.
Catalog No. Wt.
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
09/17/2008 4:50:12 PM
ADF020737
Loading...