Cooper Lighting Metalux 132T8 User Manual

Catalog #
Project
Comments
Prepared by
Date
SPECIFICATION FEATURES
08/26/2008 2:44:34 PM
Consult your representative for additional options and finishes.
Specifications and Dimensions subject to change without notice.
ADF080357
CEILING COMPATIBILITY
MOUNTING DATA
LAMP CONFIGURATIONS
MOUNTING DATA
DESCRIPTION
The accord(TM) redefines fluorescent lighting by improving on aesthetics,
comfort and energy savings. The accord(TM) provides the right amount of
light while eliminating surface shadows commonly found in parabolics.
Therefore, accord(TM) increases the comfort level while providing
significant energy savings.
The accord(TM) is the ideal solution for offices, schools, hospitals, retail and
other applications.
A ... Construction
Shallow 3-1/4" deep housing is die
formed of code gauge, prime cold
rolled steel. Heavy gauge end
plates are securely attached with
screws for strength and rigidity
and the elimination of gaps. Four
auxiliary fixture end suspension
points are provided. Large access
plate for supply connection.
B ... Electrical*
Ballasts are Class "P" and are
positively secured. Rotor-lock
lampholders ensure positive lamp
retention. UL/CUL listed. Suitable
for damp locations.
C ... Ballast Access
Ballast is mounted on a heavy
gauge access plate and can be
accessed from above the ceiling
line.
D ... Finish
Durable cold rolled steel with
multistage, iron phosphate
pretreatment and white enamel
finish to ensure maximum bonding
and rust inhibition.
E ... Reflectors
Reflector has high reflectance
baked matte white enamel finish
for luminous uniformity.
F ... Shielding
Positively retained frosted acrylic
profile lenses provide a soft but
effective distribution of light.
AC
132T8
T8 LAMP
1' X 4' Recessed
Troffer Series
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power
11-3/4" [299mm]
3-5/8"
[93mm]
A
B C
DF E
G
G r i d / L a y- i n S t a n d a r d
F
D r y wall Fr a m e K i t
C e i l i n g Tr i m Typ e** Ty p e
Exposed Grid G ConcealedT G or T Slot Grid G or T F l a n g e * * *
EB Ballast & STD Lamps @ 277V
132T8 (30)
Luminaire Efficacy Rating
LER =FL75 Catalog Number: AC-132
Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $5.01
*Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements.
**Consult Pre Sales Technical Support.
***See Drywall Frame Kit Accessory
E N ER G Y DAT A
Input Watts:
11-3/4"
[299mm]
48-3/8" [1229mm]
6"
[153mm]
X
Y
COOP ER LI GH TING - MET AL UX
®
Specifications and Dimensions subject to change without notice.
ORDERING INFORMATION
PHOTOMETRICS
SHIPPING INFORMATION
AC
S A M PL E NU MB ER : A C- 13 2- UN V-E B8 1- U
Number of Lamps
(Not included)
1=1 Lamp
Wattage (Length) 32=32W T8 (48")
Voltage
(1)
UNV=Universal Voltage
120-277
Options GL=Single Element Fuse GM=Double Element Fuse Flex=Flex installed EL=Emergency Installed
Packaging U=Unit Pack PALC=Job Pack,
in carton
Shielding Blank=Frosted Acrylic
(standard)
NOTES:
(1)
Products also available in non-US voltages and frequencies for international markets.
(2)
1' x 4' Accord is not designed for
continuous row mount applications.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
Lamps L8835=T8 Lamp,
17W and 32W, 3500K L8841=T8 Lamp, 17W and 32W, 4100K L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens
Series AC=Accord Series
Width
(2)
Blank=1' Width
Rating Blank=
Standard NY=New York Rated ATW-SW4= Chicago Rated
Ballast Type EB8 =T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
EB8 /PLUS=T8 Electronic Instant Start.
High Ballast Factor >1.13. Total Harmonic Distortion < 20%
ER8
=T8 Electronic Program Start.
Total Harmonic Distortion < 10%
HPT8 Ballast Ballast HB8
L=T8 Electronic Instant Start. Low Ballast Factor .77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 =T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2
No. of Ballast 1 or 2
No. of Ballast 1 or 2
No. of Ballast 1 or 2
HR8_DIM
C o e ffi c ie nt s of U ti li za ti on
Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0 1 2 3 4 5 6 7 8 9
10
L u m in an ce D at a
Average Average Average Angle 0-Deg 45-Deg 90-Deg in Deg cd/sm cd/sm cd/sm
45 1963 2305 2568 55 1867 2378 2739 65 1738 2438 2565 75 1476 1996 1777 85 957 957 679
Z o n al L um en S um ma ry
Zone Lumens %Lamp %Fixture 0-30 0-40 0-60 0-90 0-180
||
C a n dl ep ow e r
Angle Along II 45° Across
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
AC-132
Electronic Ballast (1) F32WT8/835 Lamp
2850 Lumens each Spacing criterion:
(II) 1.2 x mounting height, ( ) 1.4 x mounting height
Efficiency 89.8% Test Report:
AC-132.IES LER = FL75 LPW Yearly Cost of 1000
lumens, 3000 hrs at .08 KWH = $5.01
798 798 798 794 796 797 783 789 795 764 777 790 738 760 783 705 739 771 665 713 755 620 682 735 570 647 708 516 606 675 458 560 634 398 507 584 337 448 517 273 383 403 207 296 276 142 192 171
81 102 89 31 31 22
0 0 0
107 107 107 107 104 104 104 104 100 100 100 96 96 96 92 92 92 90 97 93 89 86 95 91 87 84 87 84 82 84 81 79 80 78 77 75 88 81 74 69 86 79 73 68 76 71 67 73 69 65 70 67 64 62 80 70 63 57 78 69 62 56 66 60 55 64 59 54 61 57 53 51 73 62 54 48 71 61 53 47 58 52 47 56 51 46 54 49 45 43 67 55 47 41 65 54 46 40 52 45 40 50 44 40 49 43 39 37 62 49 41 35 60 49 41 35 47 40 35 45 39 34 44 38 34 32 57 45 37 31 56 44 36 31 43 36 31 41 35 30 40 34 30 28 53 41 33 27 52 40 33 27 39 32 27 38 31 27 37 31 27 25 50 37 30 25 48 37 29 25 36 29 24 35 29 24 34 28 24 22 46 34 27 22 45 34 27 22 33 26 22 32 26 22 31 26 22 20
636 22.3 24.9 1062 37.3 41.5 1974 69.2 77.1 2559 89.8 100.0 2559 89.8 100.0
AC-132T8 22 lbs.
Catalog No . Wt.
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
08/26/2008 2:44:34 PM
ADF080357
Loading...