Cooper Lighting MCGRAW-EDISON 84 - 168W, MCGRAW-EDISON 70 - 200W, MCGRAW-EDISON 85W User Manual

COOPER LIGHTING
MCGRAW-EDISON
®
EPL
ENVOY
70-200W
High Pressure Sodium
Pulse Start Metal Halide
84-168W
Compact Fluorescent
85W
Induction
PARKING GARAGE
LUMINAIRE
ADH080511
DESCRIPTION
The McGraw Edison Envoy (EPL) is a unique presentation of form, function and unmatched versatility, making it the right choice for complex garage lighting applications. A toolless accessible housing, lens and electrical access is standard. Envoy offers solutions addressing primary and egress lighting needs for garages, canopies and other installations where maintenance, performance and longevity are required. UL and C-UL US listed for wet locations under UL1598. IP66 Rated.
DIMENSIONS
ENERGY DATA
Hi-Reactance Ballast Input Watts
70W HPS HPF (95 Watts) 70W MP HPF (90 Watts) 100W HPS HPF (130 Watts) 100W MP HPF (129 Watts) 150W HPS HPF (190 Watts) 150W MP HPF (185 Watts)
CWA Ballast Input Watts
175W MH HPF (210 Watts) 175W MP HPF (208 Watts) 200W MP HPF (240 Watts)
Electronic CF Ballast Input Watts
84W CF HPF (93 Watts) 114W CF HPF (127 Watts) 126W CF HPF (139 Watts) 140W CF HPF (154 Watts) 168W CF HPF (186 Watts)
SHIPPING DATA
Approximate Net Weight:
21.5 lbs. (9.8 kgs.)
Catalog #
Typ e
Date
Project
Comments
Prepared by
Construction
Low copper, one-piece aluminum die-cast electrical housing features heavy cast walls designed for effective heat dissipation and resistance to corrosion. Toolless aluminum die-cast latches securely hold lens in place and aid in efficient installation and maintenance. A tamper resistant option is available to prevent unauthorized access. Envoy is IP66 rated, promoting long term optical efficiency allowing for fast efficient cleaning by power washing. All gaskets contained within Envoy are silicone material including lens gasket and housing wire grommet.
Optical Lens: Lens employs a 2 part
system (upper and lower) by which the reflector is accurately located and securely locked in place. Injection molded, virgin Acrylic material is standard due to its ability to resist radiation from UV and for its superior clarity (polycarbonate is available). Lens is attached via two (2) toolless die-cast latches. When released, lens will hinge off housing and remain captive to allow for easy, obstruction free lamp placement or electrical access. Lens perimeter is completely sealed at housing junction using a one-piece extruded, vulcanized silicone gasket.
Reflectors: Envoy reflectors use premium materials and a durable finish process to ensure longevity of optical performance. The 3-part reflector system
employs a bright specular Alzak
®
anodized aluminum hydro-formed main reflector, a diffuse anodized aluminum hydro-formed upper reflector and die-formed premium 95% reflective, specular pre­anodized sheet aluminum inserts. A choice of three (3) different optical distributions with a variety of light controlling media may be used to optimize your lighting layout and comply with lighting ordinances.
Electrical
Each fixture includes all electrical components hard mounted to electrical housing for efficient operation. All HID units use medium-base type lamps with standard magnetic, high power factor ballasts (minimum starting -30°C (-22°F) MH-MP/-40°C (-40°F) HPS). Compact Fluorescent (CF) units use 4-pin lamp sockets with standard high power factor electronic ballast (minimum starting -18°C (0°F). Induction lamp features a high frequency, high power factor generator (available in 100-120V or 200­277V, minimum starting
-25°C (-13°F) The electrical reflector cover is keyed and accessed via two (2) toolless thumbscrews.
Mounting
Standard fixture mounts to a square or octagonal 4" surface or recessed mounted j-box via electro-zinc plated, heavy-gauge “quick mount” bracket system, complete with stainless steel hanger allowing “hands-free”
SPECIFICATION FEATURES
wiring connection. Enables efficient fixture mounting, wiring connection inspection and fixture removal. Quick mount plate features stainless steel springs that help absorb vibration and aid fixture to slide and lock in place. A variety of other mounting options and accessories including free swinging balanced pendant box/bird guard, trunnion mount and wall mount arm are available.
Egress Options
Envoy offers multiple egress lamp sources including quartz halogen, compact fluorescent and MR16, available in multiple circuit options. Compact fluorescent battery packs are available integral within fixture or remote mount in various wattage configurations.
Finish
Housing is finished in 5 stage premium TGIC polyester powder coat paint, 2.5 mil nominal thickness for superior protection against fade and wear. Envoy is supplied standard in grey and available in black, white and bronze. RAL and custom color matches available. Consult the McGraw-Edison Architectural Colors brochure for the complete selection.
S
Y
S
T
E
M
S
C
E
R
T
I
F
I
E
D
LAMP TYPE WATTAGE
Metal Halide
175W
Pulse Start Metal Halide 70, 100, 150, 175, 200W
High Pressure Sodium 70, 100, 150W
Compact Fluorescent (2) 42, (2) 57, (3) 42, (2) 70, (4) 42W
Induction 85W
16 3/8" (416mm)
13 1/2"
(343mm)
CERTIFICATIONS
IP66 Rated U.L. 1598 (Wet Locations) C-UL (Wet Locations)
2G Vibration Tested 40°C Ambient *
NOTES: * Varies by model.
Patents Pending
NOTE: Specifications and dimensions subject to change without notice.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADH080511
EPL ENVOY
ORDERING INFORMATION
SAMPLE NUMBER: EPL-175-MP-MB-MT-TG-AP-L-EM/SC
EPL
Product Family EPL=Envoy Parking
Garage Luminaire
Standby + Egress Options (See Below)
Colors (add as suffix/must specify) AP=Grey BZ=Bronze BK=Black WH=White
Lamp Wattage MH
1
175=175W MP
2
70=70W 100 =100W 150=150W 175=175W 200=200W HPS 70=70W 100 =100W 150=150W
Voltage
5
120=120V 208=208V 240=240V 277=277V 480=480V DT=Dual-Tap
6
MT=Multi-Tap
6
TT=Triple-Tap
6
Distribution RD=Round SQ=Square TG=Rectangular
Options (add as suffix)
7
CD=Concentrated
Downlight (Restricts Uplight 360°)
8
CT=Conduit Taps (Qty (2) 3/4" NPSM)
9
F=Single Fuse (Specify 120, 277 OR 347 in
"Voltage" column).
FF=Double Fuse (Specify 208, 240 OR 480 in
"Voltage" column)
HA=40° C Ambient
10
HL=Hi/Low Dimming
11
L=Lamp Included, HID LC=Lamp Included, Compact Fluorescent LQ=Lamp Included, Quartz Halogen DCB PH=Upper Polycarbonate Lens (Near Aluminum
Back Housing)
PL=Lower Polycarbonate Lens QD=Quick Disconnect(s) (between reflector
cover/electrical housing)
TMB=Trunnion Mount with Connection Box
(some assembly required)
TMC=Trunnion Mount with Power Cord
(some assembly required)
TR=Tamper Resistant (Torx T15 CPR) WL=24" Lead Wires
Accessories25(order
separately/replace XX with color designation) EPL/PBG-XX=Balanced Pendant
Box/Bird Guard
EPL/WM-XX=Wall Mount Arm
26
EPL/HS=House Side Shield Up and
Downlight 120° Coverage (HID Lamps Only)
27
EPL/HSCF=House Side Shield Up
and Downlight 120° Coverage (CF Lamps Only)
27
EPL/DLS=Drive Lane Shield
28
VRBT15=T15 Torx CPR Tamper
Resistant Driver Bit
VRST15=T15 Torx CPR Tamper
Resistant Screwdriver
EPL/TL=Task Light Field Install Kit
for 120V MR16 lamp (GU10 Base]
EPL/TL12V=Task Light Field Install
Kit for 12V MR16 lamp (GU5.3 Base)
Lamp Type MH=Metal Halide MP=Pulse Start Metal Halide HPS=High Pressure Sodium CF=Compact Fluorescent QL=Induction
Ballast Type MB=Magnetic
3
EB=Electronic
4
NOTES: 1 Metal Halide lamps with probe start circuit. 2 Pulse Start Metal Halide circuit includes igniter. 3 HID lamps only. 4 Must specify voltage. EB standard on CF. Available integrally in HID 100w MP (max) and 85w QL. HID
availability may vary by lamp source, wattage and voltage. For HID wattages higher than 100w, remote mount ballast possible within 5 feet of unit. Consult customer service. 5 Product also available in non-US voltages and 50Hz for international markets. Must specify voltages for battery packs. Consult your customer service representative for availability and ordering information. 6 Dual tap ballast is 120/277V wired 277V. Multi-tap ballast is 120/208/240/277V wired 277V. Triple tap ballast is 120/277/347 wired 347V. 7 Add as suffix in order shown. 8 Requires option PL for use in 40°C application with HID lamps 175-200w. 9 CT option required for through branch wiring. Through branch wiring is not available with specific configurations including HID CF egress options and fixtures with integral battery pack. 10 Not available with 85w QL and options using CF lamp sources. Requires option PH on 200-175w HID. 11 Available in 150-200w MP, 175w MH and 70-150w HPS. Operates on 24VDC type output control module. Circuit relay board is mounted internal to fixture housing with leads exiting back. Requires low voltage wires to control module to be routed in conduit. 12 For use with HID primary lamp only. Quartz lamp 100w maximum. 13 For use with 175w (max) or less HID primary lamp only. Uses (2) 4 pin CF lamps. CF minimum starting temperature 0°F (-18°C). Remote battery option requires “CT” option. 14 For use with 150w (max) or less HID primary lamp only. Uses (2) 18w 4 pin CF lamps. Battery rated minimum 32°F/ 0°C. Specify 120 or 277v in "VOLTAGE" column. 15 For use with 168, 126, 84 CF units only. Requires option “CT”. Battery supplied by others. Standby lamp combination wired by others. 16 For use with 168, 126, 84 CF units only. Battery rated minimum 32°F/ 0°C. Specify 120 or 277v in "VOLTAGE" column. 17 For use with 168, 126, 84 CF units only. Battery rated minimum
-4°F/ -20°C. Specify 120 or 277v in "VOLTAGE" column. 18 For use with 168 CF only. 19 For use with 126 CF only. 20 For use with 84, 114, or 140 CF only. 21 Task Light(s) with separate leads through back of fixture. Specify TL location by adding to back of option logic (ex.2TLA1A2)-see diagram. Some assembly required, order lamps separately. 22 For use with HID lamps only. Task Light(s) supplied wired to relay. Specify TL location by adding to back of option logic (ex.2TLA1A2)-see diagram. Some assembly required, order lamps separately. 23 Task Light(s) supplied with separate leads through back of fixture for connection to 12v circuit or battery system. Specify TL location by adding to back of option logic (ex.2TLA1A2)-see diagram. Some assembly required, order lamps separately. 24 Task Light max quantity (1), supplied with transformer. Specify TL location by adding to back of option logic (ex.2TLA1A2)-see diagram. Some assembly required, order lamps separately. 25 Order separately, replace XX with color suffix 26 Luminaires require option (WL), 24" Lead Wires. 27 Order additional shield set for more coverage (ex. 2 sets for 180° shielding) Maximum of 2 sets total. 28 Placed towards side of oncoming traffic for 60° shielding coverage. Order (2) for 2-Way traffic lanes. 29 Some options and accessories are not available in all configurations. Consult your customer service representative for ordering information.
Standby + Egress Lamp Options T4 Quartz Halogen + Compact Fluorescent Egress Options (For use with HID as primary lamp source)
Q=Quartz Restrike (hot restrike only, 120v T4 DCB quartz lamp)
12
EM=Quartz Time Delay (hot and cold restrike, 120v T4 DCB quartz lamp)
12
EM/SC=Emergency Separate Circuit (120v T4 DCB quartz lamp)
12
__CFSC=CF (1) Separate Circuit (Specify 52, 64 or 84, supplied with
120-277v electronic ballast)
13
__CFHR=CF Hot Restrike Relay (Specify 52, 64 or 84, supplied with
120-277v electronic ballast)
13
__CFTR=CF Time Delay Relay (Hot and Cold Restrike) (Specify 52, 64 or
84, supplied with 120-277v electronic ballast)
13
CFRB=CF Remote Battery Pack, sockets accommodate 26-42w CF lamps (Battery Pack
specified/supplied/wired by Others)
13
36CFIB=CF Integral Battery Pack operates (2) 18w CFL
14
CFRBT=CF Remote Battery Pack with Time Delay Relay, sockets accommodate 26-42w CF
lamps (Battery Pack specified/supplied/wired by Others)
13
36CFIBT=CF Integral Battery Pack operates (2) 18w CFL with
Time Delay Relay
14
Compact Fluorescent Egress Options (For use with CF as primary lamp source) RBP=Remote Battery Pack, sockets accommodate 26-42w CF lamps
(CF units only; Battery Pack specified/supplied/wired by Others)
15
42IBP=Integral Battery Pack, (1) 42w CF lamp standby
16
42ICB=Integral Cold Weather Battery Pack, (1) 42w CF lamp standby
17
4CF3=4 CF lamps wired as 3 independent circuits, 3 electronic ballasts (2 lamps/1 lamp/1
lamp)
18
4CF2=4 CF lamps wired as 2 independent circuits, 2 electronic ballasts (2 lamps/2 lamps)
18
3CF2=3 CF lamps wired as 2 independent circuits, 2 electronic ballasts (2 lamps/1 lamp)
19
2CF2=2 CF lamps wired as 2 independent circuits, 2 electronic ballasts (1 lamp/1 lamp)
20
MR16 Quartz Halogen Egress Options (For use with HID or CF as primary lamp source) TL__=Task Light 120v MR16 (GU10 Twist Lock Base)
21
2TL__=(2) Task Lights 120v MR16 (GU10 Twist Lock Base)
21
TLQ__=Task Light 120v MR16 wired to Hot Restrike Relay (GU10 Twist Lock Base)
22
2TLQ__=(2) Task Lights 120v MR16 wired to Hot Restrike Relay (GU10 Twist Lock Base)
22
TLEM__=Task Light, 120v MR16 wired to Time Delay Relay (GU10 Twist Lock Base)
22
2TLEM__=(2) Task Lights, 120v MR16 wired to Time Delay Relay (GU10 Twist Lock Base)
22
TL12V__=Task Light, 12v MR16 (GU5.3 Bi-Pin Base)
23
2TL12V__= (2) Task Lights, 12v MR16 (GU5.3 Bi-Pin Base)
23
TL__MR__=Task light with transformer (GU5.3 Bi-Pin Base, specify 50 or 75w lamp,
specify 120 or 277v transformer)
24
CF 84= (2) 42W 114 = (2) 57W 126= (3) 42W 140= (2) 70W 168= (4) 42W Induction 85= 85W
8 3/8"
[213mm]
Adustable to
13 1/4"
13 1/8"
[334mm]
3 7/16" [88mm]
16 5/8"
[423mm]
PENDANT BOX/BIRD GUARD (PBG)TRUNNION-MOUNT (TMB) WALL MOUNT (WM)
20 7/16" [519mm]
13 15/16" [354mm]
4 1/16"
[104mm]
Loading...