Cooper Lighting LV211 User Manual

HALO
®
Installation Instructions for LV211 End Feed
701934Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • 770.486.4800 • FAX 770.486.4801
WARNING
Avoid Fire or Electric Shock
If unsure about electrical installation
consult a qualified electrician.
1
Safety Information
Read carefully for your protection and save all instructions.
Turn off the power at fuse or circuit breaker box before installation and maintenance
Wear rubber-soled shoes and work on a sturdy wooden ladder
NOTE: Power supplies should be used on a 120-Volt or 277-Volt fused circuit. (Check labeling)
This Lighting System must be installed according to National Electric Code and local building codes.
Ground power supply to avoid potential electric shock.
To avoid a hazard to children, account for all parts and destroy all packing materials.
WARNING: Risk of fire. Most dwellings built before 1985 have supply wire rated 60°C. Consult a qualified electrician before installing.
If you are unsure about wiring, consult a qualified electrician.
Do not install any lampholder closer than 6" from any curtain or similar combustible material.
Wireway Channel is intended to be connected only to 12 volt or 24-volt secondary of an isolated type transformer supply. Do not exceed nominal supply voltage.
CAUTION: To reduce risk of fire and electrical shock, use only fixtures
and fittings intended for use with Linea LV 100 series channel, or
Linea LV-114 and LV-214 Wire Way channel.
CAUTION: Do not exceed 25-amp capacity of Wireway channel (600 watts at 24 volts).
Layout Planning
Carefully plan your layout and determine location and type of feed point and connectors required. For most installations it is recommended that the feed point be attached to the channel prior to mounting the channel to the mounting surface.
NOTE: The maximum recommended length of Wireway channel feed by a single feed point is 20' when used with electronic power supplies and 40' when used with magnetic power supplies.
HALO
®
1 Remove connector cover from connector.
2 Insert end of wireway channel into connector and tighten
connector mounting philips screw and tighten allen screws securely to bus bars.
3 Attach 1/2" trade size fitting (supplied by others) to channel
connector using speed nut. The speednut provided with LV211 must be used for surface feed.
4 Insert supply wire from transformer secondary as shown and
tighten allen screws securely. Refer to power supply instructions for recommended supply wire sizes.
5 Reinstall connector cover.
701934Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • 770.486.4800 • FAX 770.486.4801
LV211 Feed
Feeding Wireway Channel with LV211 End feed.
LV211 Feed
2
Cover
Wireway Channel
Connector Mounting Philips Screw
Cover Screw
Speed Nut
Buss Bar Allen Screw
Buss Bar Allen Screw
1/2" Tr ade Size Connector (supplied by others)
Buss Bars
LV211 Surface Feed
Buss Bars
Speed Nut
1/2" T rade Size Connector (supplied by others)
Buss Bar Allen Screws
Connector Mounting Philips Screw
1/2" Trade Size Connector
(supplied by others)
Speed Nut
Connector Mounting
Philips Screw
Buss Bars
Wireway Channel
Cover
Cover Screw
Feed Allen Screws
Buss Bar Allen Screws