TRUNNION MOUNT INSTALLATION: (Figure 11)
Note: Use minimum 90°C supply wire when installed per below procedure
and connections are made inside of condulet body.
Note: For 8-3/8” to 13-1/4” vertical adjustment (Up or Down only).
1. Install top trunnion on the ceiling using masonry anchors (provided by
others).
2. Apply sealing compound (by others) on one end of ½” nipple.
3. Screw nipple into the housing.
4. Install bottom trunnion L-brackets on the top plate (with provided #10-24
pan head screws, lock washers and nuts—Torque between 24-27 in-lb).
5. Install top plate on the housing (with provided #10-24 flat head screws—
Torque between 24-27 in-lb).
6. Pull wires from back of luminaire through nipple to make for easy routing
into condulet body.
7. Apply sealing compound to top of nipple. Screw condulet body onto nipple.
8. Install bottom trunnion L-brackets to the top trunnion (with provided 3/8"
bolts, lock washers and nuts—Torque between 17-20 ft-lb).
9. Route conduit and power supply wires to condulet body.
10. Make connections. Push excess wires and connectors back into the
condulet body.
11. Install gasket and cover.
TASK LIGHT INSTALLATION: (Figure 12)
WARNING: RISK OF FIRE! DO NOT mount on or near combustible materials.
1. Apply sealing compound on the threads of handle (provided by others).
2. Screws handle into adapter.
3. Aim handle to a preferred position and lock it in position.
4. Aim task light head to a preferred position and tighten #10-24 Allen head
screw (with provided Allen wrench).
5. Pull wires through access and restrain with wire tie.
Note: Depending on which task light option is being ordered, additional
wiring/routing will be necessary. Reference wiring diagrams shipped with
task light.
EPL Envoy
Parking Luminaire
Sheet 4 of 5
8/20/08 IMI-694
INSTALLATION INSTRUCTIONS
IMPORTANT : READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN FOR FUTURE REFERENCE
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADH080771
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation,
operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.
NOTE: Specifications and dimensions subject to change without notice.
Figure 12
Figure 11
#10-24
ALLEN HEAD
LOCK NUT
ADAPTER
HANDLE
(APPLY SEALING
COMPOUND BY OTHERS)
TASK LIGHT
HEAD
FOR VERTICAL ADJUSTMENT (UP OR DOWN ONLY)
8-3/8 TO 13-1/4” FROM TOP OF LUMINAIRE
CONDULET
BODY
TOP
TRUNNION
TOP PLATE
NIPPLE
APPLY SEALING
COMPOUND
(BY OTHERS)
#10-24
SCREW
HOUSING
BOTTOM
TRUNNION
#10-24 FLAT
CS SCREW
GASKET
COVER