Tools Required Socket, 5/16" Socket, 3/4" Deep Well Socket, Electrical
wiring tools.
NOTE: these luminaires are designed for outdoor lighting services, and should not be used in area of limited ventilation or in high ambient temperature enclosures. Construction is suitable for down lighting only. Best results will be obtained if installed and maintained according to the following recommendations.
1. Open housing door by squeezing thumb latch towards front of housing. To relieve latch pressure, compress gasket by pushing door into housing. Once the latch is disengaged, gently swing the door open. FIG. 1
2. Remove the door by opening it to 45° angle “half open/half closed” then lift it off the hook shaped hinges. FIG. 2
3. Remove the electrical compartment cover.
Hard Mount Version
• Hard mount electrical covers requires captive screws “1” & “2” to be loosened. Grab handle and remove cover. FIG. 3a
Power Tray Version
• Power tray version requires captive screw “1” to be loosened. FIG. 3a
• Grab handle and open power tray. FIG. 3b
• To remove power tray from housing, unhook pin through gap in power tray. Slide off of back pin and unplug the electrical connection. FIG. 3c
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.
Tribute
Sheet 1 of 4
1/7/08 IMI-685
INSTALLATION INSTRUCTIONS
IMPORTANT : READ CAREFULLY BEFORE INSTALLING FIXTURE.
WARNING: Risk of Fire/Electric Shock. If not qualified, consult an electrician. WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing. WARNING: Risk of Burn. Disconnect power and allow fixture to cool before changing bulb or handling fixture. WARNING: Risk of Personal Injury. Fixture may become damaged and/or unstable if not installed properly.
Tighten all fixture components to their recommended torque values. Ensure door is properly latched.
WARNING: Risk of Fire/Electrical Shock. Upside down installation can result in overheating or accumulation of water in fixture. Install right side up.
NOTE: Specifications and dimensions subject to change without notice
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADH070937
FIG. 1
FIG. 2
Open
FIG. 3a
Screw “1”
Handle
FIG. 3b
Power
Tra y
FIG. 3c
Latch
Lift
Screw “2”
Mounting the fixture
4a. Arm Mount (FIG. 4a)
Arm Mounting (Square Pole) Lay the fixture on its’ top with door removed. Remove pole cap allowing nut plate to be inserted into pole and align with bolt holes. Install threaded bolts into nut plate. Align arm (end with drain holes towards pole) and place over threaded bolts. Align holes in fixture with bolts. Route fixture supply leads through arm and into pole. Inside of fixture place lock washer and nuts onto threaded bolts, secure. Housing and arm must be square with pole. Tighten bolts to 30 ft lbs. Bolts must not be extended into fixture more than 1". Finish securing electrical connections inside of pole.
Arm Mounting (Round Pole) Installation is the same as square pole except a round pole adapter is used against the round pole.
4b. Internal Mast Arm Mount (FIG. 4b)
• Loosen the four tenon clamp bolts for insertion of the mounting tenon. Note: for the 2" pipe size tenon, remove the tear away portion of the tenon entrance gasket. To remove, grasp the aluminum gasket with pliers and twist off the pre-cut portion of the gasket.
• Pull service lead wires through the mounting tenon until about 6" extends beyond the tenon end.
• Slide the luminaire onto the tenon while guiding the service lead wires. Make sure end of tenon is against stop in housing.
• Tighten 4 tenon clamp bolts. Note: fixture can be leveled by tightening front bolts differently than rear bolts. When fixture is level, torque all 4 clamp bolts to 100 inch-pounds. Tighten bolts in alternating pattern.
• Connect service lead wires to fixture leads and anchor leads in place so they are not in contact with the reflector surface or ballast surface.
• Replace electrical compartment cover removed in step 3.
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.
Tribute
Sheet 2 of 4
1/7/08 IMI-685
INSTALLATION INSTRUCTIONS
IMPORTANT : READ CAREFULLY BEFORE INSTALLING FIXTURE.
NOTE: Specifications and dimensions subject to change without notice
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADH070937
FIG. 4a (Arm Mount)
Pole Cap
Nut Plate
Arm
Drain Hole
In This
Location
Hex Nut
Lock Washer
1/2-13 Threaded Rod.
Max. extension into housing
is 1”.
Cross Sectional View of Fixture Mounted to Pole
FIG. 4b (Internal Mast Arm Mount)
2” or 1 1/2”
Mounting
Tenon
“A”
Flip Clamps
over for 1 1/2” Pipe
Service Lead Wires
Extend Min. 6”
Electrical
Cover
Detail “A”
Tear off this part
of gasket for
2” pipe size
Housing
Stop
Tenon Clamp Bolts (qty. 4) Torque to 100 inch pounds