Cooper Lighting IMI-572 User Manual

Page 1
3. Disconnect PRIMARY QUICK-DISCONNECT by grabbing sides
and pulling away from fixture. (Fig. 3)
NOTE: Fusing and the cube starter are accessible from
the bottom, exposed side of the POWER TRAY. They may be serviced without opening the POWER TRAY.
4. Hold POWER TRAY HANDLE and press POWER TRAY
LATCH away from the power tray. Hinge power tray up and lift from fixture. (Fig. 4)
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.
Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-572 AVU040062
Ascent/Strut Fixtures
Sheet 1 of 5
4/26/04 IMI-572
INSTALLATION INSTRUCTIONS
IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE.
General: Upon receipt of fixture thoroughly inspect for any freight damage, which should be brought to the attention of the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the housing to assure you have received the correct merchandise.
Safety: This fixture must be wired in accordance with the national electrical code and applicable local codes and ordinance. Proper grounding is required to insure personal safety. Carefully observe grounding procedure. All work should be done by an electrician.
TM
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker panel or
fuse box before installing or servicing.
WARNING: Risk of Personal Injury. Fixture may become damaged and/or unstable if not
installed properly. Tighten all fixture components to their recommended torque values.
1. Open door by depressing LATCH BUTTONS into door and
lifting. (Fig. 1)
2. Remove DOOR while it is at a 20° - 30° angle to the housing.
This will allow the door to slide over and forward from the hinges. (Fig. 2)
Fig. 1
Fig. 2
Fig. 3
LATCH BUTTONS
PRIMARY QUICK DISCONNECT
FUSES
STARTER
Fig. 4
POWER TRAY HANDLE
POWER TRAY LATCH
DOOR
Page 2
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.
Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-572 AVU040062
Ascent/Strut Fixtures
Sheet 2 of 5
4/26/04 IMI-572
INSTALLATION INSTRUCTIONS
IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE.
TM
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.
5. Using WALL PLATE as a template, drill (4) holes in wall. Install
appropriate wall anchors (not supplied) and secure GASKET and WALL PLATE to wall with (4) 1/2-13 X 1-12 long BOLTS and (4) Lockwashers (Fig. 5). Torque BOLTS to 450 in/lbs.
NOTE: The SPACER, WALL BRACKET and associated
components and hardware are shipped separately from the fixture.
6. Assemble WALL BRACKET to SPACER and HOUSING with
(2) BOLTS, (2) FLAT WASHERS, and (2) LOCK WASHERS by feeding BOLTS through holes in SPACER and into tapped holes in WALL BRACKET. (Fig. 6A & 6B) Torque BOLTS as follows:
(2) 1/2 - 13 (AEM) = 450 in/lbs OR
(2) 5/16 - 18 (AES) = 130 in/lbs
WARNING
Risk of Personal Injury Fixture may become damaged and/or
unstable if not installed properly Tighten all fixture components to their
recommended torque values
WARNING: Risk of Personal Injury. Fixture may become damaged and/or unstable if not installed properly.
Tighten all fixture components to their recommended torque values.
Fig. 6A
BOLTS
LOCK
WASHERS
FLAT
WASHERS
HOUSING
SPACER
WALL
BRACKET
Fig. 6B
SUPPORT BRACKET
WALL
BRACKET
BOLTS
LOCK
WASHERS
WALL
PLATE
BOX
HOLES
GASKET
Fig. 5
Page 3
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.
Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-572 AVU040062
Ascent/Strut Fixtures
Sheet 3 of 5
4/26/04 IMI-572
INSTALLATION INSTRUCTIONS
IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE.
RETAIN FOR FUTURE REFERENCE.
TM
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.
7. Hook WALL BRACKET over WALL PLATE and place
SUPPORT BRACKET into SUPPORT HOLES in WALL PLATE to support fixture as shown. (Fig. 7)
Make wire connections in WALL BRACKET. Wire the fixture ground lead to the supply ground lead. Wire the fixture voltage lead to the supply voltage lead. Wire the fixture common lead to the supply common lead.
NOTE: To wire to circuits not having a neutral lead (such
as 480V), connect the fixture voltage lead to one of the supply leads and the fixture common lead to the other supply lead.
8. Push SUPPORT BRACKET into WALL BRACKET and lower
fixture until WALL BRACKET fits over WALL PLATE. Tighten 1/4-20 SOCKET SCREW. (Fig. 8)
NOTE: Ensure wires are not pinched while closing WALL
BRACKET to WALL PLATE.
Fig. 7
WALL
BRACKET
SUPPORT BRACKET
SUPPORT
HOLES
WALL
PLATE
Fig. 8
WALL
BRACKET
SOCKET
SCREW
Page 4
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.
Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-572 AVU040062
Ascent/Strut Fixtures
Sheet 4 of 5
4/26/04 IMI-572
INSTALLATION INSTRUCTIONS
IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE.
TM
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.
9. To reinstall POWER TRAY, hang POWER TRAY from POWER
TRAY HINGE, swing POWER TRAY up till POWER TRAY LATCH snaps closed. Reconnect PRIMARY QUICK DISCONNECT. Install lamp. Reinstall DOOR at 20°-30° angle to housing, ensuring both hinges are engaged. Close DOOR, ensuring DOOR LATCHES are completely engaged. (Listen for both cams to click on each latch). (Fig. 9)
NOTE: Prior to installing the lamp, check to make sure lamp is of
proper type and wattage. Observe lamp manufacturer’s recommendations and restrictions regarding lamp operation.
NOTE: Reflector are marked to insure reflector is installed in
proper orientation regarding Street Side. If other orientation is desired, reflector may be rotated 90° in either direction.
Fig. 11b
REFLECTOR
TABS
REFLECTOR
REFLECTOR
TABS
REFLECTOR
Fig. 11a
REFLECTOR Rotation/Removal:
10. Open DOOR by depressing LATCH BUTTONS into door.
(Reference Fig. 1)
11. To lower REFLECTOR, press the two REFLECTOR TABS
outward and swing the REFLECTOR down. (Fig. 11a & 11b). The REFLECTOR may now be lifted off of its hinges for rotation or removal.
Fig. 9
WARNING: Risk of Personal Injury. Fixture may become damaged and/or unstable if not installed properly.
Tighten all fixture components to their recommended torque values.
Page 5
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.
Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-572 AVU040062
Ascent/Strut Fixtures
Sheet 5 of 5
4/26/04 IMI-572
INSTALLATION INSTRUCTIONS
IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE.
TM
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.
NEMA TWIST LOCK PHOTOCONTROL & RECEPTACLE:
The photocontrol receptacle is factory installed and ordered with the fixture. The photocontrol is ordered separately and must be field installed. The voltage of the photocontrol must match the voltage of the fixture.
FUSING:
Single fuse is available for use with 120V, 277V or 347V fixture. Double fuse is available for use with 208V, 240V or 480V fixtures.
MAINTENANCE:
When maintenance is performed, check torque on all fasteners and tighten to specified torque if required.
CLEANING:
The reflector and door glass may be cleaned with any suitable, non-abrasive glass cleaning solution, soap or detergent and rinsed with clean water. Please remove the reflector and door from the fixture prior to cleaning.
KEEP THIS DOCUMENT FOR FUTURE REFERENCE
12. To remove the REFLECTOR, disconnect the REFLECTOR
CONNECTOR from the HOUSING. (Fig. 12)
13. To reinstall, reverse steps 12 and 11, listening for audible
clicks as REFLECTOR TABS engage REFLECTOR.
NOTE: This fixture is to be installed as a DOWNLIGHT ONLY.
This fixture is not suitable for UPLIGHT mounting configurations.
REFLECTOR
CONNECTOR
Fig. 12
WARNING: Risk of Personal Injury. Fixture may become damaged and/or unstable if not installed properly.
Tighten all fixture components to their recommended torque values.