3. Disconnect PRIMARY QUICK-DISCONNECT by grabbing sides
and pulling away from fixture. (Fig. 3)
NOTE: Fusing and the cube starter are accessible from
the bottom, exposed side of the POWER TRAY. They may be serviced without opening the POWER TRAY.
4. Hold POWER TRAY HANDLE and press POWER TRAY
LATCH away from the power tray. Hinge power tray up and lift from fixture. (Fig. 4)
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.
Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-572 AVU040062
Ascent/Strut Fixtures
Sheet 1 of 5
4/26/04 IMI-572
INSTALLATION INSTRUCTIONS
IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE.
General: Upon receipt of fixture thoroughly inspect for any freight damage, which should be brought to the attention of the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the housing to assure you have received the correct merchandise.
Safety: This fixture must be wired in accordance with the national electrical code and applicable local codes and ordinance. Proper grounding is required to insure personal safety. Carefully observe grounding procedure. All work should be done by an electrician.
TM
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker panel or
fuse box before installing or servicing.
WARNING: Risk of Personal Injury. Fixture may become damaged and/or unstable if not
installed properly. Tighten all fixture components to their recommended torque values.
1. Open door by depressing LATCH BUTTONS into door and
lifting. (Fig. 1)
2. Remove DOOR while it is at a 20° - 30° angle to the housing.
This will allow the door to slide over and forward from the hinges. (Fig. 2)
Fig. 1
Fig. 2
Fig. 3
LATCH BUTTONS
PRIMARY QUICK DISCONNECT
FUSES
STARTER
Fig. 4
POWER TRAY HANDLE
POWER TRAY LATCH
DOOR
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.
Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-572 AVU040062
Ascent/Strut Fixtures
Sheet 2 of 5
4/26/04 IMI-572
INSTALLATION INSTRUCTIONS
IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE.
TM
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.
5. Using WALL PLATE as a template, drill (4) holes in wall. Install
appropriate wall anchors (not supplied) and secure GASKET and WALL PLATE to wall with (4) 1/2-13 X 1-12 long BOLTS and (4) Lockwashers (Fig. 5). Torque BOLTS to 450 in/lbs.
NOTE: The SPACER, WALL BRACKET and associated
components and hardware are shipped separately from the fixture.
6. Assemble WALL BRACKET to SPACER and HOUSING with
(2) BOLTS, (2) FLAT WASHERS, and (2) LOCK WASHERS by feeding BOLTS through holes in SPACER and into tapped holes in WALL BRACKET. (Fig. 6A & 6B) Torque BOLTS as follows:
(2) 1/2 - 13 (AEM) = 450 in/lbs OR
(2) 5/16 - 18 (AES) = 130 in/lbs
WARNING
Risk of Personal Injury Fixture may become damaged and/or
unstable if not installed properly Tighten all fixture components to their
recommended torque values
WARNING: Risk of Personal Injury. Fixture may become damaged and/or unstable if not installed properly.
Tighten all fixture components to their recommended torque values.
Fig. 6A
BOLTS
LOCK
WASHERS
FLAT
WASHERS
HOUSING
SPACER
WALL
BRACKET
Fig. 6B
SUPPORT BRACKET
WALL
BRACKET
BOLTS
LOCK
WASHERS
WALL
PLATE
BOX
HOLES
GASKET
Fig. 5