These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible 
contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please 
contact your nearest representative.
ARM & FIXTURE INSTALLATION
Bishop Arm (VA6005-VA6008, VA6054-VA6057, VA6105-VA6108 
& VA6154-VA6157) 
See Figure 1.
1. Secure arm onto pole and orient.
2. Tighten the six set screws located near bottom of arm to 
150 in/lbs. to secure arm.
3. Loosen the three arm cap set screws and remove arm cap.
4. Pull fixture leads through arm to arm cap location.
5. Raise fixture to arm aligning locating pin and socket. 
See Figure 2.
6. Insert and tighten 4 fixture screws with Teflon washers, provided 
in polybag, to 80 in/lbs.
7. Connect fixture leads to service leads.
8. Resecure arm cap with arm cap set screws tightened to 
50 in/lbs.
Traditional Arm (VA6009-VA6021 VA6058-VA6070, 
VA6109-VA6121 & VA6158-VA6170) 
See Figure 3.
1. Slip arm onto pole and orient.
2. Tighten the six set screws located near bottom of arm to 
150 in/lbs. to secure arm.
3. Loosen the three arm cap set screws and remove arm cap.
4. Pull fixture leads through arm to arm cap location.
5. Raise fixture to arm aligning locating pin and socket. 
See Figure 2.
6. Insert and tighten 4 fixture screws with Teflon washers, provided 
in polybag, to 80 in/lbs.
7. Connect fixture leads to service leads.
8. Resecure arm cap with arm cap set screws tightened to 
50 in/lbs.
Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-575  AVU040300
Epic/Pole Mounted
Fixtures
Sheet 1 of 4
2/18/04 IMI-575
INSTALLATION INSTRUCTIONS
IMPORTANT: Read carefully before installing fixture. Retain for future reference.
General: Upon receipt of fixture thoroughly inspect for any
freight damage, which should be brought to the attention of 
the delivery carrier. Compare the catalog description listed 
on the packing slip with the fixture label on the housing to 
assure you have received the correct merchandise.
Safety: This fixture must be wired in accordance with 
the national electrical code and applicable local codes 
and ordinance. Proper grounding is required to insure 
personal safety. Carefully observe grounding procedure 
under installation section. All work should be done by a 
qualified electrician.
Fig. 1
Fig. 2a