Cooper Lighting IIMI-575 User Manual

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.
ARM & FIXTURE INSTALLATION
Bishop Arm (VA6005-VA6008, VA6054-VA6057, VA6105-VA6108 & VA6154-VA6157) See Figure 1.
1. Secure arm onto pole and orient.
150 in/lbs. to secure arm.
3. Loosen the three arm cap set screws and remove arm cap.
4. Pull fixture leads through arm to arm cap location.
5. Raise fixture to arm aligning locating pin and socket.
See Figure 2.
6. Insert and tighten 4 fixture screws with Teflon washers, provided in polybag, to 80 in/lbs.
7. Connect fixture leads to service leads.
8. Resecure arm cap with arm cap set screws tightened to
50 in/lbs.
Traditional Arm (VA6009-VA6021 VA6058-VA6070, VA6109-VA6121 & VA6158-VA6170) See Figure 3.
1. Slip arm onto pole and orient.
150 in/lbs. to secure arm.
3. Loosen the three arm cap set screws and remove arm cap.
4. Pull fixture leads through arm to arm cap location.
5. Raise fixture to arm aligning locating pin and socket.
See Figure 2.
6. Insert and tighten 4 fixture screws with Teflon washers, provided in polybag, to 80 in/lbs.
7. Connect fixture leads to service leads.
8. Resecure arm cap with arm cap set screws tightened to
50 in/lbs.
Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-575 AVU040300
Epic/Pole Mounted
Fixtures
Sheet 1 of 4
2/18/04 IMI-575
INSTALLATION INSTRUCTIONS
IMPORTANT: Read carefully before installing fixture. Retain for future reference.
General: Upon receipt of fixture thoroughly inspect for any
freight damage, which should be brought to the attention of the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the housing to assure you have received the correct merchandise.
Safety: This fixture must be wired in accordance with the national electrical code and applicable local codes and ordinance. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under installation section. All work should be done by a qualified electrician.
TM
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing
or servicing.
Bishop Arm
Arm Cap
Arm Cap Set Screws
Set Screws
Fixture Screws
Teflon Washers
Fig. 1
Aligning Pin
Aligning Socket
Modern Top
Fig. 2a
Customer First Center 1121 Hwy 74 South Peachtree City, GA 30269 IMI-575 AVU040300
Epic/Pole Mounted
Fixtures
Sheet 2 of 4
2/18/04 IMI-575
INSTALLATION INSTRUCTIONS
IMPORTANT: Read carefully before installing fixture. Retain for future reference.
TM
FIXTURE MAINTENANCE A. Relamping
Horizontally lamped
1. Loosen two door screws.
2. Lower door to tethered resting position. See Figure 4.
3. Install suitable lamp. Consult re-lamp label and lamp
instructions for details. Do not overtighten.
4. Raise door and secure with screws.
V
ertically lamped
1. Loosen and remove ring retaining screws globe retaining
ring and globe. Components are not tethered. See Figure 5.
2. Install suitable lamp. Consult re-lamp label and lamp instructions for details. Do not overtighten.
3. Reinstall ring retaining screws securing globe retaining ring and globe. In the case of type 3 refractive glass globe, use the mark on globe bottom for orientation.
B. Starter and Fuse Replacement (Where applicable)
Horizontall
y lamped
1. Loosen two door screws.
2. Lower door to tethered resting position. See Figure 4.
3. Loosen thumbscrew until rectangular washer can be rotated
90 degrees. See Figure 6.
4. Rotate reflector faceplate to release from screws using key hole slots.
5. Unplug optic quick-disconnect.
6. Remove two screws on ballast cover followed by ballast
cover. See Figure 7.
7. For starter replacement, remove the plug-in starter from receptacle and replace. For fuse replacement, unscrew fuse holder cap and replace fuse. Resecure fuse holder cap.
8. Resecure the ballast cover with the two screws.
9. Plug optic quick-disconnect and secure reflector by keyhole
slots and thumbscrew.
10. Raise door and secure with screws.
Classical Top
Aligning Socket
Aligning Pin
Fig. 2b
Arm Cap
Arm Cap Set Screws
Traditional Arm
Arm Cap
Fig. 3
Fig. 4a
Fixture Screws
Teflon Washers
Options FG, FR, SG & FRS
Door Screws
Loading...