COOPER LIGHTING - SURE-LITES
®
HZX SERIES
Hazardous Location Exit
EXIT LIGHTING
INDUSTRIAL & HAZARDOUS LOCATION Exit Signs
• 120 VAC input voltage
• Factory-sealed, explosionproof housing of copperfree aluminum
• Impact-resistant white
acrylic edgelit face panel
with 6" high red letters
• Available in pendantmount, wall-mount, or endmount styles
• Two 60W, 60T10 clear
lamps wired in parallel
• No provisions for
battery operation
• Provides safe operation in
the presence of volatile
gases, vapor or dust
• Internal rectifier extends
lamp life
• Relamping tool provided
• Listed per UL 844 for
hazardous locations up to
and including NEC Class I,
Division 1, Groups C, D and
Class II, Division 1, Groups
E, F and G, Life Safety
NFPA 101, NEC/OSHA,
most state and local codes
DESCRIPTION
The Sure-Lites HZX Series
Explosion-Proof Edgelit Exit
signs are designed for use
in locations classified as
DIMENSIONS
END
MOUNT
6"
(152mm)
WALL
MOUNT
4 3/8"
(111mm)
PENDANT
MOUNT
4 1/32"
(102mm)
15 1/2" (394mm)
hazardous due to the presence
of flammable vapors, gasses
or combustible dust. They
are suitable for use in Class I,
Division 1, Groups C and D,
and Class II, Division 1, Groups
E, F and G hazardous locations
as defined by the National
Electrical Code.
ORDERING INFORMATION
Model Number Mounting Style Sign Panel
HZX21 Wall Single Face
HZX22 End Double Face
HZX23 Pendant Double Face
NATIONAL ELECTRICAL CODE (NEC)
16 1/8"
(410mm)
16 7/8"
(429mm)
17 1/2"
(445mm)
The National Electrical Code (NEC) defines a hazardous location as “a location where fire hazards or explosion
hazards may exist due to flammable gases or vapors, flammable liquids, combustible dust or ignitable fibers or
filings.
The Code further separates these hazardous locations into three classes:
Class I – locations containing gases and vapors
Class II – locations containing dust
Class III – locations containing fibers and filings.
Each of these classes is broken into divisions. These divisions are separated into groups according to
characteristics.
The following chart summarizes these classifications:
Class Division Group
I Gas 1 Hazard Exists – Always present A Acetylene
II Dust 1 Hazard Exists E Conductive and Combustible Metal Dust
III Fibers 1 Production Areas Combustible
1 in atmosphere B Hydrogen and Manufactured Gases containing Hydrogen
2 Potential Exists – May be present A Acetylene
1 in atmosphere B Hydrogen and Manufactured Gases containing Hydrogen
2 Potential Exists F Combustible Carbon Dust
2 Handling/Storage Areas Combustible
C Petrochemicals
D Petrochemicals
C Petrochemicals
D Petrochemicals
G Non-Conductive Combustible Dust
666
COOPER LIGHTING
Energy Data
Input Current (Max.):
Model No. 120V 277V
HZX21, HZX22, HZX23 120W 1.0A
ZZ14=60T10 Halogen lamp 120V 60Watt