Cooper Lighting HR12360C, HR12210C, HR12170C, HR117C, HR12117C User Manual

...
COOPER LIGHTING - SURE-LITES
5 3/4"
(146mm)
4 1/4"
(108mm)
14 1/4"
(362mm)
8"
(203mm)
12 1/2" (318mm) 14 1/2" (368mm)
DESCRIPTION
The real workhorse in emergency lighting systems...these durable, reliable units are unparalleled in performance and provide freedom from maintenance.
The HR Series units provide a low cost, solid-state lighting system for applications in industrial, commercial, or multi-housing environments. High and Ultra High capacity makes them ideal for installations where a large number of heads/exits will be remotely operated.
DIMENSIONS
18"
(457mm)
11 3/4"
(298mm)
HR87C
HR117C
HR12117C
Steel
High Capacity
CHICAGO CODE
®
8 1/4" (210mm)
9" (229mm)
Figure 1. Ultra High Capacity
ELECTRICAL RATINGS
17 1/4" (438mm) 19 1/4" (489mm)
Figure 2. High Capacity
Rated Wattage to 87 1/2% of Rated D.C. Voltage
Model Type DC Voltage 1 1/2 Hours Lamp Watts Remote Watts Figure
HR87C SLC 6 87 24 63 1 HR117C SLC 6 117 24 93 1 HR12117C SLC 12 117 24 93 1 HR180C SLC 6 180 24 156 2 HR12170C SLC 12 170 24 146 2 HR12210C SLC 12 210 24 186 2 HR12360C SLC 12 360 24 336 2
*Batteries may be shipped separately.
SLC=Sealed Lead Calcium
ORDERING INFORMATION
SAMPLE NUMBER: HR87CTDM
Model Number HR87C HR117C HR12117C HR180C HR12170C HR12210C HR12360C
Options (add as suffix) Alternate Lamps A=Ammeter V=Voltmeter TDM=Time Delay Monitor Other Option
(1)
(1)
Accessories (order separately) VK-1 =Voltmeter
3BRWH =Mounting Brackets, White Finish 2MSWH =Mounting Shelf, White Finish (For High Capacity Fixtures) 3MSWH=Mounting Shelf, White Finish (For Ultra High Capacity
Fixtures)
CSK120=Cord Set 120VAC CSK277=Cord Set 277VAC VS2=Polycarbonate Vandal Shield WG7=Wire Guard, For High Capacity Fixtures WG3=Wire Guard, For Ultra High Capacity Fixtures
Lamp Information
Type Wattage Number
Halogen 12 29-66 Halogen 12 29-66 Halogen 12 29-45 Halogen 12 29-66 Halogen 12 29-45 Halogen 12 29-45 Halogen 12 29-45
HR180C HR12170C HR12210C HR12360C
Steel
Ultra-High Capacity
CHICAGO CODE
• Dual-voltage input 120/277VAC, 60Hz
• 18 gauge die formed steel housing and cover
• White finish
• Two top mounted, fully adjustable, white, metal heads with die-cast swivel standard
• Sealed lead-calcium battery
• Knockout, conduit or cord set
• Remote capability
Energy Data
Input Current (Max.):
Model No. 120V 277V HR87C .50A .21A HR117C .53A .22A HR12117C .26A .13A HR180C .98A .43A HR12170C 1.08A .45A HR12210C 1.02A .47A HR12360C 1.17A .54A
(1)
Consult your Cooper Lighting Representative.
• Line-latching, Solid-State voltage limited charger, Solid-State switching, low-voltage disconnect, brownout circuit, overload/short-circuit protection, test switch/power indicator light
• UL 924 Listed, Life Safety NFPA 101, NEC/OSHA, most state and local codes
• City of Chicago approval Number 3238