Cooper Lighting HALO miniLUME LA5300, HALO miniLUME LF5300, HALO miniLUME L5300 Installation Instructions Manual

• SAFETY INFORMATION
• IMPORTANT SAFETY INSTRUCTIONS
• READ CAREFULLY FOR YOUR PROTECTION AND SAVE ALL INSTRUCTIONS
Disconnect power before installing light fixture on track.
Wear rubber-soled shoes and work on a sturdy wooden ladder.
Code and local building codes.
To avoid a hazard to children, account for all parts and destroy all
packing materials.
If you are unsure about the installation or use of this fixture con-
sult a qualified electrician.
CAUTION: To reduce the risk of fire and electrical shock, use only
fixtures and fittings intended for use with Halo and Lazer by Halo track systems only.
Installation Instructions for LA5300, LF5300 & L5300 Adjustable Beam Lampholders
HALO
®
HALO
®
Operation This device has an internal ceramic metal halide transformer allowing it to operate on Halo and Lazer by Halo line voltage track. Make sure you are using the correct lamp type and wattage for your track fixture. In the event of a shutdown the lamp will re-strike in approximately 5 minutes
NOTICE: THIS EQUIPMENT CONTAINS A R.F. BALLAST THAT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS PURSUANT TO PART 18C NON-CONSUMER LIMITS OF THE FCC RULES. THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE WITH ELECTRONIC DEVICES SUCH AS: RADIOS, TELEVISIONS, WIRELESS TELEPHONES OR REMOTE CONTROLS. IF INTERFERENCE OCCURS IT MAY BE POSSIBLE TO CORRECT THE INTERFERENCE BY ONE OR MORE OF THE FOLLOWING MEASURES:
• REORIENT OR RELOCATE ANTENNA OF THE RECEIVING DEVICE.
• INCREASE THE SEPARATION BETWEEN THIS EQUIPMENT AND THE DEVICE.
• CONNECT THIS EQUIPMENT OR THE DEVICE INTO A DIFFERENT OUTLET OR CIR­CUIT.
THIS EQUIPMENT SHOULD NOT BE USED:
• CLOSER THAN THREE (3) FEET FROM ANY SENSITIVE ELECTRONIC EQUIPMENT.
• NEAR MARITIME SAFETY, NAVIGATION, OR COMMUNICATIONS EQUIPMENT.
Service
There are no user serviceable parts inside. Opening unit will void warranty. Contact point of purchase for service.
Installation Instructions for L5300 Series Track Fixture (Fig. 1A, 1B, 1C & 1D)
The L5300 track fixture can be used with Halo and Lazer by Halo single circuit track and Halo-2 two-circuit track. An adjustable con­tact allows you to select the circuit position. Use a narrow blade screwdriver as shown (Fig.1A) to adjust the contact. Lift or lower the contact until it touches the upper or lower plastic stop of the contact assembly. To use with Halo or Lazer by Halo single circuit track the adjustable contact must be in the circuit #1 or lower position. To use with Halo-2 two circuit track adjust the contact position to the desired circuit position, circuit #1 down or circuit #2 up position (Fig. 1B).
ADJUSTABLE CONTACT
FIG. 1A
FIG.1B
Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • 770.486.4800 • FAX 770.486.4801
11/06 rev.4 702505
Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • 770.486.4800 • FAX 770.486.4801
11/06 rev.4 702505
FOCUSING KNOB
HORIZONTAL LOCK
9/64" ALLEN WRENCH
FIG.13
VERTICAL LOCK
9/64" ALLEN WRENCH
FIG. 12
FIG. 11
Changing Media
The fixture bezel assembly can accept two clear glass lenses or one color filter with or without a clear lens.
Focusing Beam
Focus by rotating knob 1/4 turn on fixture. Beam can be adjusted from a spot to a flood (Fig. 11).
Instructions for Lockable Aiming
Lockable aiming is only available for L530070E series fixtures.
Step 1 Aim fixture to desired position.
Step 2 Insert 9/64 allen wrench, provided by others, into hole under track
adapter. Turn clockwise to tighten. This will lock vertical rotation (Fig.12).
Step 3 Insert 9/64 allen wrench into hole near on/off switch. Turn clock-
wise to tighten. This will lock horizontal rotation (Fig. 13).
DOWN POSITION
UP POSITION
HALO
®
SWITCH
LAMP (do not twist)
Do not touch lamp with bare fingers - hold lamp with cloth
FIG. 7
FIG. 10
HALO
®
TRACK POLARITY GROOVE
INSERT FIXTURE IN TRACK AND THEN TWIST 90°
FIXTURE POLARITY GROOVE
FIXTURE POLARITY GROOVE
THUMB LATCH
FIG. 1C
FIG. 1D
To install the fixture to the track, insert the contact assembly into the track and rotate the fixture neck 90° so the polarity line on the power supply aligns with the polarity line on the track. Pull back and release the thumb latch allowing the power supply to lock into position (Fig 1C and 1D).
To remove the fixture, slide thumb latch down until latch is clear of the track channel opening. Twist the fixture neck and turn (90°) until the contact assembly is free and remove power supply from track.
Installation Instructions for LA5300 Series Track Fixture (Fig. 2)
The LA5300 track fixture can be used with Halo two circuit Architectural Track.
Fixture can be rotated 180° to second circuit.
To install fixture into track, open switch cover so that contacts are concealed inside fixture. Insert fixture into track so the contact will engage the desired circuit. Close switch cover.
To remove fixture, rotate switch cover 90° and remove from track. (Fig. 2)
Installation Instructions for LF5300 Series Track Fixture (Fig. 3)
The LF5300 track fixture can be used with Halo ‘LF’ series 2 two-circuit track only.
Step 1. Open connector cover by pulling downward on the connector sleeve
and connector cover so that the contacts are exposed.
Step 2. Raise fixture to track with contacts facing intended circuit. Step 3. Move connector into position and close connector cover until it snaps
into position.
To remove fixture from track.
Step 1. Open connector cover by pulling downward on the connector sleeve. Step 2. Raise fixture from track and remove.
Note: To access the other circuit, rotate fixture 180 degrees and follow
installation instruction above.
Relamping Instructions
Warning: Before working on fixture, be sure to turn off AC power or remove
fixture from track.
Step 1 Allow unit to cool then remove from track
Step 2 Remove bezel and glass assembly by rotating assembly counter-
clockwise (Figs 4 & 5).
Step 3 Remove glare shield by pulling both ends of the glare shield straight
out (Fig. 6).
Step 4 Locate the relamp label on the outer surface of the reflector to deter-
mine the required lamp wattage for proper fixture operation (Fig. 6).
Step 5 Remove the existing lamp by pulling straight out.
Step 6 Using a soft cloth to avoid contacting the new lamp with bare hands,
insert the replacement lamp into the socket by carefully aligning the lamp pins to the socket and pushing the lamp straight into the socket without twisting (Fig. 7). Insure lamp pins are inserted properly into the socket for proper lamp function.
FIG. 2
FIG. 3
BEZEL & GLASS ASSEMBLY
FIG. 4
CONNECTOR COVER
CONNECTOR SLEEVE
Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • 770.486.4800 • FAX 770.486.4801
11/06 rev.4 702505
Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • 770.486.4800 • FAX 770.486.4801
11/06 rev.4 702505
FIG. 9
REFLECTOR HOUSING
FIG.8
LUGS
Step 7 Replace the glare shield and bezel and glass assembly by carefully
engaging all three lugs on the bezel with the corresponding lugs on the reflector housing (Fig. 8). Turn the bezel and glass assembly clockwise until the positive ‘click’ is felt, indicating the home position has been engaged in the reflector housing (Fig. 9). Verify the bezel and glass assembly is securely retained in the reflector housing.
Step 8 DO NOT OPERATE FIXTURE WITHOUT GLASS LENS. RISK OF FIRE.
Be sure on-off switch is returned to ON position (Fig 10).
FIG. 5
FIG. 6
GLARE SHIELD
BEZEL & GLASS ASSEMBLY
RELAMP LABEL