Cooper Lighting H750T Installation Manual

Page 1
HALO
®
WARNING AVERTISSEMENT
Risk of Fire Supply conductors (power wires) con­necting the fixture must be rated mini­mum 90°C If uncertain, consult an electrician
Risk of Electric Shock Disconnect power at fuse or circuit breaker before installing or servicing
Risk of Fire/Electric Shock If not qualified, consult an electrician
WARNING: For your safety read and understand instruc-
tions completely before starting installation. Before wiring to power supply, turn off electricity at the fuse or circuit breaker box. Halo recessed fixtures are designed to meet the latest NEC requirements and are UL listed in full compliance with UL 1598. Before attempting installation of any recessed fixture check your local electrical code. This code sets the wiring standards for your locality and should be carefully studied before starting.
NOTE: If fixture is to be switched from wall switch or dimmer, make sure black supply wire is properly con­nected to the switch or dimmer ( follow switch/dimmer instructions). DO NOT connect the white supply wire to the switch.
• Make certain no bare wires are exposed outside the connectors.
• Fixture is designed for installation where it will NOT come in contact with insulation. Thermal insulation must be kept a minimum of 3” away from the hous­ing (Fig. 1).
• Bar hangers for this fixture are of interlocking design to allow positioning of housing along entire length of bars. Position bar hangers as shown (Fig. 2).
• Bar Hangers may be shortened to fit 12" framing by breaking at score lines. Pass bar hangers through each end until the bars overlap, then break off at score lines (no tools required and bar hangers do not need to be removed from plaster frame) (Fig. 3).
Step 1. Locate fixture between joists (Fig. 1) Step 2. Extend bar hangers to fit between joists. Position
fixture by hammering nails into joists. Bar hangers should be level with bottom of joists (Fig. 2)
Step 3. Follow steps 1 through 4 under “Electrical Connection”.
Step 4. Adjust position of fixture on bar hangers as needed. To secure fixture in position, tighten screw and/or bend prongs on plaster frame over bar hangers (Fig. 2).
Step 5. Adjust fixture for ceiling thickness by loosening the hex screws that attach the housing to the plaster frame. Bring bottom edge of housing flush with ceiling line (Fig. 3).
Step 1. Locate center of proposed opening on ceiling
Step 2. Place ceiling tile in T-Bar grid.
Figure 1
Installation in New Construction
Installation in Suspended Ceilings
tile and cut a 6-1/2” size hole:
Ceiling Line / Plafond /Linea del techo
Figure 3
Risque d'incendie Le calibre des fils d'alimentation de l'appareil d'éclairage doit être d'au moins 90 °C. En cas de doute, consultez un électricien.
Risque de chocs électriques Coupez l'alimentation au niveau du fusible ou du disjoncteur avant d'effectuer toute installation ou réparation.
Risque d'incendie/de chocs électriques Si vous n'avez pas les qualifications requises, consultez un électricien.
AVERTISSEMENT: Pour votre sécurité, veuillez lire et comprendre toutes les instructions avant de débuter l'installation. Avant de raccorder l'alimentation, coupez le courant au niveau du boîtier de fusibles ou de dis­joncteurs. Les appareils d'éclairage encastrés Halo sont conçus pour répondre aux exigences les plus récentes du Code national de l'électricité et sont homologués UL conformément à la norme UL 1598. Avant d'entreprendre l'installation de tout appareil d'éclairage encastré, consultez votre code électrique local. Ce code indique les normes de câblage de votre localité et doit être revu attentivement avant de débuter l'installation.
Installation dans une construction neuve
REMARQUE : Si l'appareil d'éclairage est destiné à être commandé par un interrupteur mural ou un gradateur, assurez-vous que le fil d'alimentation noir est bien rac­cordé à l'interrupteur ou au gradateur (suivez les instructions de l'interrupteur/du gradateur). Ne rac­cordez PAS le fil d'alimentation blanc à l'interrupteur.
• Assurez-vous qu'aucun fil nu n'est exposé, en dehors des connecteurs.
• Le dispositif a été conçu pour une instalaltion où ce dernier risque de toucher le matériau isolant. L'isolation thermique doit demeurer à au moins 3" du logement (Voir fig. 1).
• Les barres de suspension de cet appareil d'éclairage ont une caractéristique de verrouillage. Le boîtier peut ainsi être positionné sur toute la longueur des barres. Positionnez les barres de suspension comme illustré (fig. 2).
• Les barres de suspension peuvent être raccourcies pour s'adapter à un cadre de (12 po). Pour cela, il faut les casser au niveau des traits de coupe.
Étape 1. Positionnez l'appareil d'éclairage entre les solives, (fig. 1).
Étape 2. Déployez les barres de suspension pour qu'elles se calent entre les solives. Positionnez l'appareil d'éclairage en enfonçant des clous dans les solives à l'aide d'un marteau. Les barres de suspension doivent être alignées avec le bas des solives (fig. 2).
Étape 3. Suivez les étapes 1 à 4 de la section « Raccordement électrique ».
Étape 4. Ajustez la position de l'appareil d'éclairage sur les barres de suspension, selon nécessité. Pour immo­biliser l'appareil d'éclairage, serrez la vis et/ou repliez les broches du cadre en plâtre sur les barres de suspen­sion (fig. 2).
Figure 2
Crimp slot for pliers Fente de sertissage pour les pinces Ranura de engaste para los alicates
Bar hanger locking screw Vis de verrouillage de barre de suspension Tornillo de fijación del col­gador de barra
Bar Hanger Locking Prongs Broches de verrouillage de barre de suspension Puntas de fijación del colgador de barra
ADVERTENCIA
Riesgo de incendio Los conductores de suministro (cables eléctricos) que conectan el accesorio deben estar clasificados para 90˚C míni­mo. Si usted no está seguro de esto, con­sulte a un electricista
Riesgo de choque eléctrico Desconecte la corriente en la caja de fusibles o interruptor de circuito antes de instalar o darle servicio al accesorio
Riesgo de incendio/choque eléctrico Si usted no está calificado, consulte a un electricista
ADVERTENCIA: para su seguridad, lea y entienda com­pletamente las instrucciones antes de empezar la insta­lación. Antes de cablear el accesorio al suministro eléc­trico, apague la electricidad en la caja de fusibles o interruptor de circuito. Los accesorios empotrados Halo están diseñados para cumplir con los últimos requer­imientos del Código Eléctrico Nacional (NEC, por sus siglas en inglés) y están listados por UL en cumplim­iento total con la clasificación UL 1598. Antes de inten­tar la instalación de cualquier accesorio empotrado, revise su código eléctrico local. Este código fija los estándares de cableado para su localidad y debe ser cuidadosamente estudiado antes de empezar.
Instalación en construcciones nuevas
NOTA: si el accesorio va a ser encendido desde un
interruptor de pared o atenuador, asegúrese de que el cable de suministro negro esté conectado adecuada­mente al interruptor o atenuador (siga las instrucciones del interruptor/atenuador). NO conecte el cable de sum­inistro blanco al interruptor.
• Cerciórese de que no hayan cables desnudos expuestos fuera de los conectores.
• La unidad está diseñada para ser instalada de modo que no tenga contacto directo con ningún material aislante. Este material debe mantenerse a una distan­cia minima de tres pulgadas (3") de la cubierta (Fig 1).
• Los colgadores de barra para este accesorio tienen un
diseño de acoplamiento que permite el posicionamien­to de la caja a lo largo de toda la longitud de las barras. Coloque los colgadores de barra como se muestra (Fig.
2).
• Los colgadores de barra pueden ser acortados para
ajustarse al marco de 12” (30,5 cm) rompiéndolos en las líneas marcadas.
Paso 1. Localice el accesorio entre las vigas fig. 1). Paso 2. Extienda los colgadores de barra para que
quepan entre las vigas. Coloque el accesorio martillan­do los clavos dentro de las vigas. Los colgadores de barra deben estar nivelados con la parte inferior de las vigas (fig. 2).
Paso 3. Siga los pasos del 1 al 4 bajo “Conexión eléctri­ca”.
Paso 4. Ajuste la posición del accesorio en los col­gadores de barra como sea necesario. Para asegurar el accesorio en posición, apriete el tornillo y/o doble las puntas en el marco de yeso sobre los colgadores de barra (fig. 2).
Bar hanger lip fits against joist bottom Le rebord de la barre de sus­pension repose contre le bas de la solivegador de barra El borde del colgador de barra se ajusta contra la parte inferior de la viga
Paso 5. Ajuste el accesorio para el grosor del techo aflojando los tornillos hexagonales que acoplan la caja al marco de yeso. Mueva el borde inferior de la caja hasta que quede a ras con la línea del techo (fig. 3).
Instalación en un Cielo Falso
Paso 1. Marque, sobre el ele-
mento móvil del cielo raso falso,
el punto por donde entrará el
portalámpara y recorte unhueco
H7=6-1/2” diámetro Paso 2. Coloque sobre el ele-
mento móvil del cielo raso fal­sola rejilla de la barra en “T”.
Paso 3. Encaje la lámpara sobre las bar-ras en T Asegurar con un tornillo (noincluido) como se muestra (Fig. 4).
de
Cooper Lighting 1121 Highway 74 South, Peachtree City GA 30269 704632
Page 2
Hanger tab Hole Orificio de le lengueta del colgador Trou de la languette du support
(1-5) Alternate Mounting Holes Los puntos de montaje alternados Autres points de montage
Automatic levelling flange La brida de nivelacion automática La bride de mise à niveau automatique
Step 3. Snap fixture on T-bars. Secure with screw (not included as shown (Fig. 4).
Step 4. Follow Steps 1 through 4 under “Electrical Connection”.
Step 5. Center fixture over opening. To secure fix­ture position in ceiling, tighten screw and/or squeeze tabs into hanger bars to lock fixture in place (Fig.2)
4
3
1
Strapped Ceiling Guide Hole
5
Trou de la langette du support Perfaracion guia para cielo raso elistnado
2
Installation in New Construction - Strapped Ceiling
Option 1. Nail installation on the joist
• Use guide hole below nail to align bar hanger bracket below joist to adjust for the strapping.
• Align guide hole below the joist to where you just see through the guide hole and nails into joists.
• Additional fasteners may be used in hanger tab hole
Option 2. Installation on strapping
• Use levelling flange to position housing on bot­tom of strapping ( strapping must be 12” to 24” apart).
• Use slot or hole in levelling flange to secure the
bar hanger bracket to the strapping with nails or screw (not included).
Electrical Connection
• Make certain no bare wires are exposed outside the connectors.
• For housings with push-nut connectors:
- Strip insulation on supply wires 1/2"
- Use 12-16 AWG stranded (stranded pattern 19 or
less) or use 12-18AWG solid copper wire.
Step 1. Provide electrical service according to the “National Electrical Code" or your local electrical code from a suitable junction box to the wiring box (located on the plaster frame). Supply wire insula­tion must be rated for at least 90°C.
Step 2. Remove the fixture wiring box cover. Note: The fixture wiring box will accept metal con-
duit or non-metallic cable, but metal conduit must be used if your electrical code requires it.
Metal conduit: Remove appropriate round knock­out(s) and connect conduit to wiring box with prop­er connector(s) (not included). Figure 5
Non-metallic Cable Open door of required cable traps. After making connections per Step 3, cable is to be inserted into cable trap as outlined in Step 4.
Step 3. Connect supply wires to wires in fixture wiring box with proper size wire nuts (not included) or push wires into “push-in” connectors (included on select models). Be sure to cover all bare current­carrying conductors. Connect white to white; black to black; and green or bare copper wire (from electrical service) to bare copper wire (in wiring box). Figure 5
Note: The ground wire at the service junction box may need to be secured to a ground screw.
Step 4. Insert non metallic cable into cable trap, then make a 90° L-shaped bend in cable as shown (Fig. 6).
Step 5. Place wires and connections back in wiring box and replace cover.
LED Module installation
Follow instructions with LED module for installation
Non-metallic cable Câble non métallique Cable no metálico
Make a 90° L shaped bend in cable Puis tordez-le à 90° de manière à former un L Cable no metálico Luego haga un doblez a 90˚ en forma de L en el cable
T grid clip Pinza de rejilla de la barra en T Clip de frille en T
Étape 5. Ajustez l'appareil d'éclairage en fonction de l'épaisseur du plafond en desser­rant les vis à tête hexag­onale qui fixent le boîti­er sur le cadre en plâtre. Alignez le bord inférieur du cadre de niveau avec le plafond (fig. 3).
Installation pour les Plafonds Suspendus
Étape 1 Marquer le cen-
tre de l’ouverture sur la tuile du plafond et faire un trou.
Figure 5
Cable traps Pièges à câble Trampas para cable
Round knockouts for metal conduit Trous défonçables ronds pour câble métallique Troqueles redondos para conducto metálico
Figure 6
H7=6-1/2”
Étape 2 Placer la tuile dans la grille de la barre en «T». Étape 3. Placer l’appareil sur les supports en T. Les fixer à l’aidede vis
(non fournies) comme illustré (Fig. 3). Étape 4. Suivre dans l’ordre les étapes 1 à 4 de la section intitulée
«Connexions Électriques». Étape 5. Centrer l’appareil par-dessus l’ouverture. Pour qu’ildemeure
fixé au plafond, serrer la vis et/ou rentrer les pattesdans les supports afin de bloquer l’appareil contre les supports(Fig. 2).
Installation dans une nouvelle construction – Plafonds suspendus
Option 1 Clouer l’installation sur l’entretoise.Utiliser le trou de guidage
au-dessous du clou pour alignerle support au-dessous de l’entretoise afin de l’ajuster à l’é-paisseur du plafond suspendu
Aligner le trou de guidage au-dessous de l’entretoise en face del’endroit où il est possible de voir à travers celui-ci et enfoncerles clous dans les entretoises.
Des clous et des vis supplémentaires peuvent être utilisés dansle trou de la languette du support.
Option 2 Installation sur un plafond suspendu Utiliser une bride de mise à niveau pour positionner le boîtier aubas du
plafond suspendu (le plafond suspendu doit être espacéd’environ 12 po à 24 po)Utiliser une encoche ou un trou dans la bride de mise à niveaupour fixer le support au plafond suspendu à l’aide de clous oude vis (non fournis)
Raccordement électrique
• Assurez-vous qu'aucun fil nu n'est exposé, en dehors des connecteurs.
• Pour les boîtiers à connecteurs à écrou capuchon :
- Dénudez les fils d'alimentation sur 1,3 cm (1/2 po).
- Utilisez un fil torsadé de calibre AWG 12 à 16 (motif torsadé de 19 ou moins) ou un fil en cuivre massif de calibre AWG 12 à 18.
Étape 1. Effectuez le raccordement électrique conformément au Code national de l'électricité ou à votre code local, d'une boîte de jonction appropriée à la boîte de câblage (située sur le cadre en plâtre). Le calibre de l'isolant des fils d'alimentation doit être d'au moins 90 °C.
Étape 2. Retirez le couvercle de la boîte de câblage de l'appareil d'éclairage.
Remarque : La boîte de câblage de l'appareil d'éclairage est compatible avec les câbles métalliques et non métalliques, mais un câble métallique doit être utilisé si votre code électrique le requiert.
Câble métallique: Retirez le(s) trou(s) défonçable(s) rond(s) approprié(s) et raccordez le câble à la boîte de câblage avec le(s) connecteur(s) approprié(s) (non compris). Figure 5
Câble non métallique: Ouvrez le couvercle des pièges à câble requis. Après avoir effectué les raccordements décrits dans l'étape 3, insérez le câble dans le piège à câble.
Étape 3. Raccordez les fils d'alimentation aux fils de la boîte de câblage de l'appareil d'éclairage avec les capuchons de connexion appropriés (non compris) ou enfoncez les fils dans les connecteurs à écrou capu­chon (compris avec certains modèles). Veillez à recouvrir tous les con­ducteurs nus sous tension. Raccordez le fil blanc au fil blanc, le fil noir au fil noir et le fil vert ou de cuivre nu (de raccordement électrique) au fil de cuivre nu (de la boîte de câblage). Figure 5
Remarque: Il peut s'avérer nécessaire d'immobiliser le fil de terre de la boîte de jonction avec une vis de terre.
Étape 4. Insérez le câble métallique dans le piège à câble, puis tordez-le à 90° de manière à former un L, comme illustré (fig. 6).
Étape 5. Replacez les fils et les connexions dans la boîte de câblage et remettez le couvercle en place.
DEL Module Installation
Follow instructions with LED module for installation
Figure 4
Optional Facultatif Opcionales
Paso 4. Siga los Pasos 1 a 4 descritos en“Conexión Eléctrica.”
Paso 5. Centre la lámpara sobre elhue­co en el cielo raso. Para fijar la posi-ción de la lámpara sobre el cielo raso, ase­gure el tornilo y/o inserte las lengüetas en los colgadores de barra para blo­quear la lámpara sobre los col­gadores(Fig. 2)
Instalación en una Construcción Nueva
– Cielos rasos enlistonados
Opción 1 Colocar clavos en la
viga.Utilice la perforación guía debajo delclavo para alinear el soporte del col­gador de barra debajo de la viga y regu­lar el grosor del enlis-tonado.
Alinee la perforación guía que está debajo de la viga hasta quepueda ver a través de la perforación guía y coloque los clavoscon la ayuda de un martillo.
Los clavos y los tornillos adicionales pueden ser utilizados en elorificio de la lengüeta del col­gador.
Opción 2 Instalación del listonado Use la brida de nivelación para colocar el bastidor
en la parte inferior de la conexión (debe haber espacio de 12” a 24” entre las conexiones)
Use la ranura o el orificio de la brida de nivelación para asegurar el soporte del colgador de barra al enlistonado, con clavos o tornillos (no incluidos)
Conexión eléctrica
• Cerciórese de que no hayan cables desnudos expuestos fuera de los conectores.
• Para cajas con conectores de tuerca a presión:
- pele el aislante de los cables de suministro 1/2” (1,3 cm).
- use cable de cobre sólido 12-16 AWG trenzado (patrón trenzado de 19 o menos) o 12-18 AWG.
Paso 1. Provea el servicio eléctrico según el “Código Eléctrico Nacional” o su código eléctrico local de una caja de conexiones adecuada a la caja de cables (localizada en el marco de yeso). El aislante del cable de suministro debe estar clasifi­cado para al menos 90˚C.
Paso 2. Retire la cubierta de la caja de cables del accesorio.
Nota: la caja de cables del accesorio aceptará cable de conducto metálico o cable no metálico, pero debe usarse conducto metálico si su código eléctrico así lo requiere.
Conducto metálico: quite el troquel redondo apropiado y conecte el conducto a la caja de cables con el(los) conector(es) adecuado(s) (no incluido [s]). Figura 5
Cable no metálico: abra la puerta de las trampas para cable requeridas. Después de hacer las conexiones como se explican en el Paso 3, el cable debe ser insertado dentro de la trampa para cable.
Paso 3. Conecte los cables de suministro a los cables en la caja de cables del accesorio con las tuercas del tamaño adecuado (no incluidas) o empuje los cables dentro de los conectores “a presión” (incluidos en modelos seleccionados). Cerciórese de cubrir todos los conductores de corriente desnudos. Conecte el blanco con el blanco, el negro con el negro, el verde o el cable de cobre desnudo (del servicio eléctrico) al cable de cobre desnudo (en la caja de conexiones). Figura 5
Nota: el cable de conexión a tierra en la caja de conexiones del servicio podría necesitar ser ase­gurado a un tornillo de conexión a tierra.
Paso 4. Inserte el cable no metálico dentro de la trampa para cable y luego haga un doblez a 90˚ en forma de L en el cable como se muestra (fig.
6).
Paso 5. Coloque los cables y las conexiones de nuevo en la caja de cables y vuelva a colocar la cubierta.
Screw Vis Tornillo
LED Module Instalacíon
Follow instructions with LED module for installation
Cooper Lighting 1121 Highway 74 South, Peachtree City GA 30269 704632