Cooper Lighting FAIL-SAFE SCG, FAIL-SAFE SCH Specification Sheet

COOPER LIGHTING
FAIL-SAFE
®
CLEANROOM
DIMENSIONSDESCRIPTION
The Fail-Safe SCG12, SCG24 and SCH24 Series are designed for use in horizontal or non­laminar air flow clean rooms and features the added convenience of field retrofitting for flange or grid installations.The enclosed and gasketed housing and door protect against infiltration of airborne bacteria. Fixtures tested to 100 PSI hose down. Higher ratings available (consult factory). The mitered edges on the door frame and the hole-free design of the housing prevent air exchange between the fixture and plenum, allowing relamping without contamination of the clean areas. An emergency battery pack is available as an option. Fixtures are U.L. listed and C.S.A. standard wet label. These luminaires are manufactured in accordance with U.S.D.A., F.D.A., N.S.F. and Federal Standard 209E. The SCG12 Series is suitable for use in I.E.S. Class 10 (M2.5), 100 (M
3.5), 1,000 (M 4.5), 10,000 (M
5.5) and 100,000 (M 6.5) clean room environments.
• Lens is clear extruded with prisms positioned inside fixture and smooth surface on the outside for easy cleaning
• Flush mounted, stainless steel machine screws
• Nominal 4-1/4" (SCG24) or 5" (SCG12/SCH24) deep recessed one-piece 20 ga. CRS housing
• Unique, Particulock™ lens retention system. Lens is hermetically sealed to door frame
• Optional extruded aluminum, mitered, fully gasketed, outside flanged door; or one-piece, die­formed stainless steel door
• Standard Class P, CBM/ETL ballast
• MicroSeal
TM
gasketing system features silicone RTV sealant sealing lens to door frame and extruded silicone rubber gasketing seals door to ceiling. White, closed cell Flexiseal™ seals fixture to ceiling
• Gasketed access plate with two flattened, 7/8" diameter knockouts
SCG SCH
34W-160W
Fluorescent
1' x 2', 1' x 4', 2' x 2', 2' x 4'
SPECIFICATION GRADE FLUORESCENT GRID 1", 1-1/2" or 2" Grid
B
C
MOUNTING
B
C
B
A
A
B
DOOR FRAME
AB C
SCG12 5" 11 11/16" 24"
1'x 2' (127mm) (297mm) (610mm) SCG12 5" 11 11/16" 48" 1'x 4' (127mm) (297mm) (1219mm) SCG24 4 1/4" 23 11/16" 24" 2'x 2' (108mm) (602mm) (610mm) SCG24 4 1/4" 23 11/16" 48" 2'x 4' (108mm) (602mm) (1219mm) SCH24 5" 23 3/16" 24" 2'x 2' (127mm) (589mm) (610mm) SCH24 5" 23 3/16" 48" 2'x 4' (127mm (589mm) (1219mm)
Extruded aluminum mitered door frame and housing trim flange with extruded silicone rubber perimeter gasketing
One piece stainless steel door frame and housing trim flange with extruded closed cell silicone perimeter gasketing
ORDERING INFORMATION
SAMPLE NUMBER: SCG-24-340-277-IK12-LE3-ALP-GLR
Voltage 120=120V 277=277V 347=347V UNV=120V
through 277V
Lens Type IK12=K-12
Prismatic Acrylic
IP12=K-12
Prismatic Polycarbon ate
KSH25
1
=Bat
Wing Distributi on
93=Prismatic
Tempered Glass
Ballast LE3=Energy
Saving Ballast
Electronic Ballast
2
EB81=(1) Ballast
for use with T8 Lamp
EB82=(2) Ballasts
for use with T8 Lamp
EB21=(1) Ballast
for use
with T12
Lamp
EB22=(2) Ballasts
for use with T12Lamp
EBX1=(1) Ballast
for use with Biaxial Lamp
EBX2=(2) Ballasts
for use with Biaxial Lamp
Options EBP=Emergency
Battery Pack
GLR=Fuse and
Holder
RIF=Radio Frequency
Interference Filter
Housing Options SHN=Stainless Steel,
Brushed 304 Finish
SHP=Stainless Steel,
Polyester Powder Finish
ALH=Aluminum,
Polyester Powder Finish
Door/Finish Options ALP=Aluminum
Door & Trim, Polyester Powder Finish
ALX=Extruded
Aluminum Door & Trim, Clear Anodized Finish
ALXP=Extruded
Aluminum Door & Trim, Polyester Powder Finish (Standard)
Series SCG=Specification
Grade Cleanroom Grid Type
SCH=Specification
Grade Cleanroom Heavy Grid Type
Width 12=12" 24=24"
Lamp Type
24" Fixture Length
T8 Fluorescents 117=(1) 17W Lamp 217=(2) 17W Lamps 317=(3) 17W Lamps 417=(4) 17W Lamps
T12 Fluorescents 120=(1) 20W Lamp 220=(2) 20W Lamps 320=(3) 20W Lamps 420=(4) 20W Lamps
U Lamps* 2U 1 5/8=(2)31W T8
Lamps
3U 1 5/8=(3) 31WT8
Lamps
2U6T8=(2) 32WT8 Lamps 2U6=(2)40WT12Lamps
Biaxial Fluorescents 140BX=(1) 40W Lamp 240BX=(2) 40W Lamps 340BX=(3) 40W Lamps
48" Fixture Length
T8 Fluorescents 132=(1) 32W Lamp 232=(2) 32W Lamps 332=(3) 32W Lamps 432=(4) 32W Lamps
T12 Fluorescents 140=(1) 40W Lamp 240=(2) 40W Lamps 340=(3) 40W Lamps 440=(4) 40W Lamps
Notes: For additional options, consult your Cooper Lighting Representative. Specifications and Dimensions subject to change without
notice.
1
The KSH25 provides improved visual performance and wide angle distribution. This lens has an integral prism pattern designed so that
prisms face the lamp cavity and still supply superior photometrics. Highly recommended for all high tech manufacturing environments.
2
For specific electronic ballast, specify brand and catalog number.
1488
Loading...