Cooper Lighting Fail-Safe MPWA series Specifications

Page 1
COOPER LIGHTING
FAIL-SAFE
®
MEDICAL/TASK & UNDERCABINET
• Up light: .125" thick, prismatic K12 pattern, acrylic lens is standard; Down light: .125" thick, contoured drape formed, prismatic K12 pattern, acrylic lens is standard
• Nickel-plated thumbscrews are standard (requires no tools to remove lens assembly)
• Housing is 18 gauge, die­formed, cold rolled steel with seam-welded ends
• MPWA uses T8 Linear Fluorescent or T5 HO Linear Fluorescent
• Ballast Options include T8 Electronic Instant Start, T5 Electronic Programmed Start and T8 Magnetic-HPF
• High gloss white polyester powder coat finish is standard on exterior housing; interior reflector is high reflectance white
• UL/CUL Listed for Damp Locations
DIMENSIONS DESCRIPTION
Fail~Safe’s MPWA series combines a multi-function, wall mounted luminaire with the architectural styling of today’s healthcare environment. Through innovative features, the MPWA accommodates for multiple applications throughout the healthcare environment while offering an appealing and highly styled design for all architectural tastes. The MPWA luminaire has been designed with the patient and healthcare professional in mind.
MPWA
51W–216W
Fluorescent
ARCHITECTURAL
HEALTHCARE
WALL MOUNTED
LUMINAIRE
1493
MOUNTING
ORDERING INFORMATION
SAMPLE NUMBER: MPWA-2/232-120-EB83-EXLL-PS4
Series
MPWA = Medical
Patient Wall Architectural
Ballast
3 Electronic Ballasts are Standard
EB83=T8 EB53=T5
LEOC8=Magnetic
energy savings ballast (T8 only, min. 3 per fixture)
1
Switching Control Options PICK ONE BELOW
or (if no switching option is specified, fixture ships with leads left unwired for switch wiring completed in field)
PS4=4 position pull chain
2
PS1D=2 position
pull chain (controls bottom lamp only, upper lamps on separate circuit)
2
LVCP=Low voltage
controller, patient controlled (patient controls all lamps)
1
LVCF=Low voltage
controller, facility controlled as needed
1
Finish Options
(If not specified, fixture ships with standard high gloss white finish)
MF=Metallic Finish DP=Dark Platinum IH=Almond Finish
Custom Colors are available (specify or supply sample, requires a flat fee, consult customer service) SSN=Stainless Steel Natural (brushed
finish)
SSP=Stainless Steel Painted (Standard
high gloss white or specify finish)
(i.e. SSP-DP)
Options EBP=Emergency battery pack
1
(no red, yellow, or green charge light will be provided)
FNL=Fluorescent Night Light,
2-pin (G23 Base), 7 or 9w twin tube (Lamps by others).
GCO=Grounded Convenience
Outlet, right side mounted facing unit
2
(Non Hospital Grade Only)
GCOL=Grounded Convenience
Outlet, left side mounted facing unit
2
GLR=Fuse and holder NRLR=White LED Nurse Chart
Reading Light, right side mounted facing unit
2
NRLL=White LED Nurse Chart
Reading Light, left side mounted facing unit
2
RIF=Radio Interference Filter. For
use with T8 magnetic ballast only (1 per ballast)
1
SFP=Machine Screws, Philips Head
Natural Stainless Steel
SF1=Tamper-proof Torx™-Head
Fasteners
Exam Light EXLR=Exam Light,
Switch Right Side Mounted Facing Unit. EXLL=Exam Light, Switch Left Side Mounted Facing Unit.
Voltage 120=120V 277=277V 347=347V UNV=120V
through 277V
Lamp Type
24" Nom. Length
T8 Fluorescents 1/217=(3) 17W
Lamps 1 Up, 2 Down
2/217=(4) 17W
Lamps 2 Up, 2 Down
T5HO Fluorescents 1/224=(3) 24W
Lamps 1 Up, 2 Down
2/224=(4) 24W
Lamps 2 Up, 2 Down
36" Nom. Length
T8 Fluorescents 1/225=(3) 25W
Lamps 1 Up, 2 Down
2/225=(4) 25W
Lamps 2 Up, 2 Down
T5HO Fluorescents 1/239=(3) 39W
Lamps 1 Up, 2 Down
2/239=(4) 39W
Lamps 2 Up, 2 Down
48" Nom. Length
T8 Fluorescents 1/232=(3) 32W
Lamps 1 Up, 2 Down
2/232=(4) 32W
Lamps 2 Up, 2 Down
T5HO Fluorescents 1/254=(3) 54W
Lamps 1 Up, 2 Down
2/254=(4) 54W
Lamps 2 Up, 2 Down
Accessories
(Order Separately) MBC=Momentary button cord switch.
May be used with LVCP or LVCF options to control lamps. (See Switching Controls).
VRSD=TORX
®
-Head Vandal Resistant
Screwdriver
Notes: For additional options, consult your Cooper Lighting Representative.
Special Claims: When mounting, installer must verify fixture weight in selecting proper
anchoring; when not anchoring directly to stud. Refer to installation instructions.
The depicted luminaire is not rated for hazardous locations or adverse environments. Illustrations and photographs depicted in this literature are representative examples only. Consult the appropriate certified and licensed lighting engineering and installation professionals for site-specific applications of products and codes.
Specifications and dimensions subject to change without notice.
1
Due to internal size limitations, some configurations and options are not available with other options. Consult customer service.
2
120V only