Cooper Lighting ELTXL6N534KZ, TXL4N474KZ, TXL5W754KZ, TXL5W554KZ, ELTXL4N254KZ Installation Instructions

...
Instruction Leaflet K1040V4
September 2015
IP66
FOR SENSOR
Tufflite LED
Product luminaires comply with EN60598 and are suitable for use in normal interior conditions. This luminaire has an ambient temperature range of -25 C to 25 C for the non-emergency version For Emergency variants - This luminaire has an ambient temperature range of 5 C to 25 C, to ensure the batteries work correctly
1
IMPORTANT: ISOLATE
SUPPLY BEFORE
SERVICING
Unclip diffuser and remove. Squeeze centre clips to remove geartray assembly
a
b
3
Use fixing brackets supplied to either surface mount or suspend fitting from fixing surface. WARNING: Direct mounting without using the supplied
fixing brackets may damage the luminaire
Surface Mounted/Suspended Mounted (Suspension wires supplied seperately)
(See table in box 2)
Top View
10.0
This luminaire is IP66 rated, this rating only applies when the luminaire is mounted observing the correct orientation and must not be positioned in direct sunlight. In exterior applications luminaires must be protected under a canopy or cover. Housings are not suitable for mounting with the base directly on a vertical surface in the horizontal orientation.
6.0
R3.0
D
D2
(See table in box 2)
o o
Note: 1840mm length fittings have 4 mounting positions, 2 of the 4 are to be used
o o
Drill suitable cable entry at specified locations only. Use cable gland, nut
2
and sealing washer supplied (ensure sealing washer is on outside of fitting) to maintain IP rating and provide strain relief. NOTE: Gland is suitable for min 6mm - 12mm max dia cable. Ensure any unused cable entry points are sealed to maintain IP rating
C
C2
Wattage
1200mm 1200mm 1500mm 1500mm 1800mm
1800mm
4
Hang geartray from hooks in housing, feed mains cable through cable entry and wire terminal block as per below:
Mains
Emergency
Note: Product suitable for looping with max conductor size 2 x 2.5mm²
SINGLE
TWIN
SINGLE
TWIN
SINGLE
TWIN
N
L
N
L
L1
L W H
101 101
1277 1277
101 101
1573 1573
101 101
1840 1840
- Blue (Neutral)
- Green/Yellow (Earth)
- Brown (Switched) Live
- Blue (Neutral)
- Green/Yellow (Earth)
- Brown (Switched) Live
- (Unswitched) Live
101145
101145
101145
VERSIONS
C
1050 1050
1340 1340 1620 1620
For Sensor Versions:
Sensor supplied loosely connected for packing. Please secure the sensor to the housing in accordance with the sensor leaflet supplied.
NOTE: If a sensor is used, the fitting will be rated IP65.
DALI Dimming:
Where applicable a 2 way terminal is provided in the luminaire geartray.
IP65
C2
1170 1170
1460 1460 1742 1742
D
800 800
1100 1100 1480 1480
20.5
D2
-
-
-
­510 510
5
CLICK!
Push geartray back into posiiton, ensuring it secures back into housing clips
6
Fit diffuser back to housing, ensuring all clips are fastened
b
a
Instruction Manual - K1040V4
September 2015
7
!! CRITICAL TO SAFETY !!
Fit Qty 4 fixing screws (supplied)
Tufflite LED
All Fitting Sizes - Second clip position from each end, on both sides.
Housing clip has two holes, one in the front par t and one in the hinge part. Align holes and initially insert screw by hand. If fitting is surface mounted, it is recommended to use a flexible screwdriver adaptor for final tightening
DO NO OVER TIGHTEN SCREWS!
Housing
Clip Hole
Safe Operation
1. Check the rating label for voltage and frequency before connecting this luminaire to the electrical supply.
2. Ensure that the mains supply is sw itched off when working on this luminaire, whether installing or carrying out any other servicing.
3. To prevent damage to driver, do not mix with conventional mag netic ballasts on the same electrical circuit.
4. Where use in more onerous situations is required, e.g. In part-completed buildings before “dr ying-out” is completed, or areas where ambient temperatures are outside the normal temperature range, then consult our Sales Office.
5. The light source contained in this luminaire shall only be replaced by the manufacturer or his ser vice agent or a similar qualified person.
6. Do not alter dip switch settings.
Servicing and Disposal
1. At commissioning and handing over of installation ensure that a copy of these instructions is presented to the authority responsible for the operation and maintenance of the luminaries.
2. Servicing , e.g. cleaning, must only be car ried out after the electricity supply has been switched off. It must not be assumed that luminaries with lamps not lit are switched off-always check before servicing.
3. Cleaning should be carried out at regular intervals to ensure that dirt does not accumulate to an extent that will impair the thermal safety or optical per formance of the luminaire. Regular cleaning will also ensure that the optical performance of the luminaries is maintained.
4. Avoid touching the LED array sur face. To clean - Blow surface with either dry air or nitrogen gas.
5. At the end of life the luminaire is classed as WEEE under directive 2002/96/EC and should be disposed of in accordance with local legislation.
Luminaire Cleaning
End of Life and Components Disposal
WEEE
Eaton
Wheatley Hall Road, Doncaster, South Yorkshire, DN2 4NB
Sales
T: +44 (0)1302 303303 F: +44 (0)1302 367155 E: sales@cooper-ls.com
General
+44 (0)1302 321541 +44 (0)1302 303220 technical@cooper-ls.com
International Sales
+44 (0)1302 303250 +44 (0)1302 303251 export@cooper-ls.com
K1040V4
Loading...