Cooper Lighting E7T, M42T, P7 User Manual

CATALOG#: TYPE:
Specification grade 42 Watt triple tube compact fluorescent fixture rated for direct contact with insulation. The 50° cutoff to lamp and lamp image provides a glare free, smooth, medium beam distribution. Triple tube lamps provide excellent
color, long life, and low radiant heat. Unit can be relamped from above. Lamp module and
A
...
Reflector
.040 thick aluminum spun parabolic upper and lower reflector. Upper reflector is specular clear, lower reflector available in iridescent free Clear, Gold, Haze, Warm Haze Alzak®, or painted gloss white finish. Special cone colors listed below.
B
...
Flange
Self flange reflector or die-cast flange with either matte white or clear coat finish. Die-cast flanges are easily removed for field painting. Elements are keyed for proper insertion.
C
...
Attachment
Positive torsion springs pull flange tight to ceiling. Mechanical light trap eliminates spill light at edge of flange or reflector. The two reflectors are keyed for top relamping.
D
...
Socket
4 pin G24q4 base for 42W PLT, TBX and TTT lamps (G24q3 for 32W lamps). Fatigue-free stainless steel spring ensures positive lamp retention. Fixed socket height ensures consistent lamp position.
E
...
Electronic Ballast
Thermally protected, current controlled rapid start ballast produces full light output and rated lamp life. Provides flicker-free and noise-free operation and starting with 120 or 277 volt input. Meets strin­gent Class B requirements, FCC part 18, for non­commercial applications.
F
...
Electrical
Keyed quick connect provides easy lamp module installation.
G
...
Frame/Housing
Hot dipped galvanized 20 gauge steel frame with built in 1/2 inch plaster lip. Gunsights allow for consistent alignment. Aluminum .032 thick housing allows for heat dissipation and reduces weight. Top is removable for above ceiling access.
H
...
Junction Box
18 cubic inches, listed for 4#12 AWG or 6#14 AWG 90° C additional feed through conductors, has six 1/2 inch pryouts.
I
...
Bar Hangers
No Flex®bar hangers with positive locking, for use with wood, engineered wood and steel frame joists spaced up to 24" O.C. ship with platform. For use in T-bar ceilings order accessory MBCLP clips. Nailess barb and locator lip provide consis­tent installation height.
Codes
Thermally protected, IP labeled, for use in direct contact with insulation. Meets Air tight require­ments, 1995 CABO Model Energy Code.
Labels
UL and cUL listed, standard damp label, IBEW union made.
ADI030703
SPECIFICATION FEATURES
H
C
B
A
D
G
I
E
F
M42T=42W Compact Fluorescent Ballast
M32T=32/26W Compact Fluorescent Ballast
M32TLutron=32W Tu Wire Dimmable Ballast (32W lamp only)
Blank=White Die-cast SF=Self Flange RAW=Natural Die-cast SWF=Self Flange
Painted White
ORDERING INFORMATION
Complete unit consists of a platform, module and element
P7
P7=7" Airtight IC rated
FlangeLamp ModulePlatform
COOPER LIGHTING
P7 M42T M32T
E7T
42W Triple 32W Triple
Compact Fluorescent
7" DOWNLIGHT
6
3/4
"
ENERGY DATA M42T
Input Power: 120V = 48W Input Current (Max.): 120V = .45A Power Factor: 120V = > .99 T.H.D.: 120V = < 10%
M32T
Input Power: 120V = 36W Input Current (Max.): 120V = .306 Power Factor: 120V = > .98 T.H.D.: 120V = < 10%
M32T Lutron
Input Power: 120V = 36W Input Current (Max.): 120V = .33A Power Factor: 120V = > .95 T.H.D.: 120V = < 20%
DESCRIPTION
11"
[280mm]
12 1/4"
[312mm]
8 1/4"
[210mm]
16 3/4"
[426mm]
6 3/4"
[172mm]
7 3/4"
[197mm]
8 1/4"
[210mm]
For Emergency Option order P732TEMER or P742 TEMER and E7T— see catalog for order­ing information. For additional options please consult factory.
Accessories
MBCLP=40 Push On T Bar Clips (for 10 Units)
PLE7=Plaster Lip Extension for Max 2" Thick Ceiling
Finish
Standard
C=Clear H=Haze G=Gold WMH=Warm Haze W=Gloss White B=Black MW=Matte White
Custom
K=Cognac KH=Cognac Haze
Custom Cont.
CC=Chocolate CCH=Chocolate Haze BU=Blush BUH=Blush Haze GP=Graphite GPH=Graphite Haze PN=Pine PNH=Pine Haze SK=Sky SKH=Sky Haze
Optical
Element
E7T= 7" Triple Tube Downlight Relfector
Ceiling Cutout
7 3/4" (197mm)
PHOTOMETRICS
P7-M42T-E7TC
Test No. H35091 Lamp: 42W PLT
Lumens: 3200 Cutoff: 50°
Spacing: 1.0 Efficiency: 44.8% Unit LPW: 27.0
Unit Number: P7-M42T-E7T_
P7-M32T-E7T_
Candelas
Vertical CD Angle
90 0 85 0 75 0 65 0 55 1 45 142 35 594 25 947 15 1313
5 1397 0 1279
Luminance
Degree cd/m
2
85
˚
0
75
˚
0
65
˚
0
55
˚
76
45
˚
8768
4'6" 5'6" 6'6" 8'0" 10'0" 12'0"
4'6" 5'6" 6'6"
8'0" 10'0" 12'0"
63 42 30 20 13
9
Cone of Light
Distance to Initial Nadir Beam Illuminated Plane Footcandles Diameter
Notes and Formulas:
Luminance: To convert cd/m
2
to footlamberts, multiply by 0.2919
Cone of Light:
• Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
• Footcandle values are initial. Apply appropriate light loss factors where necessary. See page 64-65 of catalog.
CU Notes/Formulas:
• maintained illuminance=lamp lumens x CU x light loss factors room area
• total number of luminaires=total room area x maintained illuminance
lamp lumens x CU x light loss factors
• CU data based on 20% effective floor cavity reflectance.
80% 70% 50% 30% 0%
70 50 30 10 50 10 50 10 50 10 0
53 53 53 53 52 52 50 50 48 48 45 50 48 47 45 47 44 45 43 43 42 40 47 45 43 41 44 40 42 39 41 39 37 45 42 39 37 41 37 40 36 39 36 35 43 39 36 34 38 34 37 34 37 33 32 40 36 34 32 36 31 35 31 34 31 30] 38 34 31 29 34 29 33 29 32 29 28 36 32 29 27 32 27 31 27 31 27 26 34 30 27 25 30 25 29 25 29 25 24 33 28 25 24 28 23 27 23 27 23 23 31 26 24 22 26 22 26 22 26 22 21
Ceiling Reflectance
Wall Reflectance
Room Cavity Ratio
0 1 2 3 4 5 6 7 8 9
10
Coefficient of UtilizationZonal Lumen Summary
Zone Lumens %Lamp %Luminaire
0-30 933 29.2 65.1 0-40 1299 40.6 90.6 0-60 1433 44.8 100.0 0-90 1433 44.8 100.0 90-180 0 0.0 0.0 0-180 1433 44.8 100.0
Distribution
P7-M32T-E7TC
Test No. H35094 Lamp: 32W PLT
Lumens: 2400 Cutoff: 50°
Spacing: 0.9 Efficiency: 43.4% Unit LPW: 28.9
Candelas
Vertical CD Angle
90 0 85 0 75 0 65 0 55 1 45 75 35 371 25 701 15 1083
5 1159 0 1083
Luminance
Degree cd/m
2
85
˚
0
75
˚
0
65
˚
0
55
˚
76
45
˚
4631
4'6" 5'6" 6'6" 8'0" 10'0" 12'0"
4'0" 5'0" 6'0" 7'6" 9'0"
11'0"
54 36 26 17 11
8
Cone of Light
Distance to Initial Nadir Beam Illuminated Plane Footcandles Diameter
80% 70% 50% 30% 0%
70 50 30 10 50 10 50 10 50 10 0
52 52 52 52 50 50 48 48 46 46 43 48 46 45 43 45 43 44 41 42 40 38 46 43 41 39 42 39 41 38 40 37 36 44 40 38 36 40 36 39 35 38 35 33 41 38 35 33 37 33 36 33 36 32 31 39 35 33 31 35 31 34 30 34 30 29 37 33 31 29 33 29 32 28 32 28 27 35 31 29 27 31 27 30 26 30 26 26 34 29 27 25 29 25 29 25 28 25 24 32 28 25 23 27 23 27 23 27 23 22 30 26 24 22 26 22 26 22 25 22 21
Ceiling Reflectance
Wall Reflectance
Room Cavity Ratio
0 1 2 3 4 5 6 7 8 9
10
Coefficient of UtilizationZonal Lumen Summary
Zone Lumens %Lamp %Luminaire
0-30 733 30.5 70.4 0-40 964 40.2 92.6 0-60 1041 43.4 100.0 0-90 1041 43.4 100.0 90-180 0 0.0 0.0 0-180 1041 43.4 100.0
Distribution
Note: Specifications and Dimensions subject to change without notice.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801
ADI030703
Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1B8 905.507.4000 FAX 905.568.7049