Cooper Lighting E362, E380, E370, E360 User Manual

DIMENSIONS
COMPLIANT
Cutoff
DARK SKY
CO
12 1/2"
Round
[318 mm]
11 1/2"
[292 mm]
4 5/8"
[118 mm]
5 3/4"
[146 mm]
14 3/16"
[360 mm]
1/2" [13 mm]
Max.
ORDERING INFORMATION
SAMPLE NUMBER: SRF-M-39-MHT6-MT-MB-PC-BK
Product Family SRF=Solas Series
Round Flush
Wall Type D=Dry Wall C=Concrete Pour M=Masonry Wall
Options F=Single Fuse (120, 277 or 347V) Specify Voltage FF=Double Fuse (208, 240 or 480V) Specify Voltage TP=Tamper Proof Hardware (TORXTMCenter Pin Reject) EM/SC=Quartz Emergency Separate Circuit L=Lamp included
1, 2
17
Lamp Wattage
3
HID 35=35W 50=50W 70=70W 100=100W HID T6 Lamps 39=39W 70=70W Compact Fluorescent 26=26W 32=32W 42=42W 52=52W 57=57W 64=(2) 32W 84=(2) 42W LED H.O. 18=18W
Lamp Type MH=Metal Halide
4
HPS=High Pressure Sodium MHT6=Metal Halide T6 CF=Compact Fluorescent
5
LEDRD=LED Red Lamps LEDBL=LED Blue Lamps LEDGN=LED Green Lamps LEDOR=LED Orange Lamps LEDCY=LED Cyan Lamps
6
LEDWH=LED White Lamps
7
18
19
18
6
8
8
8
8
8
Accessories SSRFC=Stainless Steel Round Flush Cover CURFC=Copper Round Flush Cover LED Replacement Lamp Kit (order separately) LED RD/RK=Red LED Lamp Replacement Kit LED BL/RK=Blue LED Lamp Replacement Kit LED GN/RK=Green LED Lamp Replacement Kit LED OR/RK=Orange LED Lamp Replacement Kit LED CN/RK=Cyan LED Lamp Replacement Kit LED WH/RK=White LED Lamp Replacement Kit
9
Voltage 120=120V 208=208V 240=240V 277=277V 347=347V 480=480V DT=Dual-Tap
8
Wired 277V
MT=Multi-Tap
Wired 277V
TT=Triple-Tap
Wired 347V
UNV=120/277V
Universal Electronic Ballast
21
10, 11
12
13
ORDERING INFORMATION (Back Housing. Must be order separately)
SAMPLE NUMBER: SRBH-D
13 15/16"
Product Family SRBH=Solas Series
Round Back Housing
Product Family D=Dry Wall CM=Concrete Pour or
2, 3
Masonry Wall
11 1/2"
[292 mm]
12 1/16"
[306 mm]
[354 mm]
DESCRIPTION
The SOLASTMSeries family of modular faceplate designs provide a tasteful architectural statement equally suitable for indoor and outdoor environments. Available solid stainless and copper faceplate covers add a premium look to flush faceplate fixtures. SOLAS Series luminaires are for recessed wall mounted applications only.
In HID lamps with “SL” lens option.
16
14
20
Colors BK=Black AP=Grey BZ=Bronze WH=White DP=Dark Platinum GM=Graphite Metallic
Ballast Type MB=Magnetic
Ballast
EB=Electronic
Ballast
Lens Type FR=Frosted
Flat Glass
SL=Clear Prismatic
Spread Lens
PC=Polycarbonate
Lens, Translucent
15
White
(See Below)
INVUE
TM
SOLAS SERIES
18-100W
High Pressure Sodium
Compact Fluorescent
ARCHITECTURAL
RECESSED LOW LEVEL
WALL LUMINAIRE
• One piece die-cast aluminum construction
• One piece die-cast aluminum faceplate utilizes a continuous silicone gasket to seal securely to housing. Faceplate is mounted with two (2) point screws. ADA compliant
• 95% reflective anodized aluminum sheet. Optical segments are rigidly mounted inside a heavy wall aluminum housing for superior protection
• Removable power tray for ease of maintenance. Conduit splice box provides six (6) 3/4" NPS hubs for supply connection
TM
SRF
ROUND
Metal Halide
LED
LOW LEVEL
WATTAGE TABLE
SRF
Metal Halide ED-17 50, 70, 100W
High Pressure Sodium 35, 50, 70W
Metal Halide T6 39, 70W
Compact Fluorescent 26, 32, 42, 57W
Dual Compact Fluorescent (2) 26, (2) 32, (2) 42W
LED High Output 18W
NOTES: 1 If insulation material is used, it must be kept minimum 3" away from luminaire on all sides. 2 All HID units for drywall or combustible applications will require a
dual- or multi-tap magnetic ballast allowing use of insulation detector as required by Code. CF units have built in thermal protection; insulation detector will be taken out of circuit. 3 All HID ED-17 lamps are medium-base. 4 35W HPS available in 120V only. 5 100W MH available only in "C" Concrete Pour and "M" Masonry Wall units. 6 CF lamps use electronic ballast 120-277V (UNV) only. 7 Nominal M.O.L lamp length of 57W CFL not to exceed 7". 8 Available with electronic ballast, 120V only. 9 Products also available in non-US voltages and 50Hz for international markets. Consult factory for availability and ordering information. 10 Dual-tap is 120/277V wired 277V. 11 Not available in 70W MH medium-base M98 lamp. 12 Multi-tap is 120/208/240/277V wired 277V. 13 Triple-tap is 120/277/347V wired 347V. 14 Available in 50W MH or less, 120-277V universal voltage, not available with HID units in Dry Wall (D) applications. "EB" standard on all Compact Fluorescent. 15 70W HID max., 84W compact fluorescent max. 16 Custom and RAL color matching available upon request. Consult your INVUE Lighting Systems Representative for further information. 17 Add as suffix in the order shown. 18 Available on 50W or less only. 19 For use only with 39W T6 MH lamp. Backup lamp is Halogen 120V T4, G9 base 40W maximum. 20 Copper cover supplied with baked lacquer finish to maintain finish prior to installation. Over time copper will weather to a natural patina finish. 21 Order separately. 22 Specifications and dimensions subject to change without notice.
4 7/16"
[112 mm]
5 3/4"
[146 mm] MAX.
Certifications
IP66 Rated
CSA Listed
Recessed wall mount only.
U.L. 1598 ADA Compliant
25°C Rated ISO 9001
CO
Cutoff
• Available for indoor and outdoor applications utilizing drywall, OSB, concrete pour and brick/masonry. Maximum depth back housing protrudes into wall is 5 3/4"
• Available in stainless steel or pure copper and comes with circular brushed finish
• Approximate net weight: 19 lbs. (8.64 kgs.)
COOPER LIGHTING
1125