Cooper Lighting CFF User Manual

FAIL-SAFE
D
C
A
B
®
CLEANROOM
CFF
17W-160W
Fluorescent
1' x 2', 1' x 4', 2' x 2', 2' x 4' FLUORESCENT FLANGE ONE PIECE DOOR
• Lens is clear extruded with prisms positioned inside fixture and smooth surface on the outside for easy cleaning
DESCRIPTION
The Fail-Safe CFF Series is designed for use in horizontal or non-laminar air flow clean rooms. The enclosed and gasketed housing and one­piece, outside flanged door protect against infiltration of airborne bacteria. The die formed edges on the door frame and the hole-free design of the housing prevent air exchange between the fixture and plenum, allowing relamping without contamination of the clean areas. These luminaires are U.L. listed and C.S.A. certified for wet locations and are manufactured in accordance with U.S.D.A., F.D.A., N.S.F. and Federal Standard 209E guidelines. 200 PSI Hose Down Rating standard. The CFF Series is suitable for use in I.E.S. Class 100, 1,000, 10,000 and 100,000 clean room environments.
DIMENSIONS
B
CEILING CUT-OUT DIMENSIONS DOOR FRAME
C
D
CFF 4" 10 3/4" 11 1/16" 24 5/16"
1' x 2' (102mm) (273mm) (281mm) (617mm) CFF 4" 10 3/4" 11 1/16" 48 5/16"
1' x 4' (102mm) (273mm) (281mm) (1227mm) CFF 3 3/4" 22 11/16" 23 1/16" 24 5/16"
2' x 2' (95mm) (576mm) (586mm) (617mm) CFF 3 3/4" 22 11/16" 23 1/16" 48 5/16" 2' x 4' (95mm) (576mm) (586mm) (1227mm)
ABCD
A
• Flush mounted, stainless steel machine screws
• Die-formed, 20 ga. CRS housing contains no holes. Standard white high reflectance polyester powder coat finish
• Unique, Particulock™ lens retention system utilizes continuous, 18 ga. media clampdowns
• Two braided, stainless steel cables on one side of door provide hinging
• One-piece, 18 ga., fully gasketed, outside flanged door
• Standard Class P, CBM/ETL ballast
• White, closed cell, Flexiseal™ triple gasketing system
• Gasketed access plate with two flattened, 7/8" diameter knockouts
ORDERING INFORMATION
SAMPLE NUMBER: CFF-24-340-277-IK12-LE3-GLR
Series CFF=Fluorescent
Flange Type
Width 12=12" (3 Lamp Max) 24=24"
Lamp Type
2' Fixture Length
T5 Fluorescents 114=(1) 14W Lamp 214=(2) 14W Lamps 314=(3) 14W Lamps 414=(4) 14W Lamps
T8 Fluorescents 117=(1) 17W Lamp 217=(2) 17W Lamps 317=(3) 17W Lamps 417=(4) 17W Lamps
T12 Fluorescents 120=(1) 20W Lamp 220=(2) 20W Lamps 320=(3) 20W Lamps 420=(4) 20W Lamps
U Lamps 2U 1 5/8=(2)31W T8
Lamps
3U 1 5/8=(3) 31WT8
Lamps
2U6T8=(2) 32WT8
Lamps
2U6=(2)40WT12Lamps
Biaxial Fluorescents 140BX=(1) 40W Lamp 240BX=(2) 40W Lamps 340BX=(3) 40W Lamps
4' Fixture Length
T5 Fluorescents 128=(1) 28W Lamp 228=(2) 28W Lamps 328=(3) 28W Lamps 428=(4) 28W Lamps
T8 Fluorescents 132=(1) 32W Lamp 232=(2) 32W Lamps 332=(3) 32W Lamps 432=(4) 32W Lamps 632=(6) 32W Lamps
T12 Fluorescents 140=(1) 40W Lamp 240=(2) 40W Lamps 340=(3) 40W Lamps 440=(4) 40W Lamps
Voltage 120=120V 277=277V UNV=120V
through 277V
Lens Type IK12=K-12 Prismatic
Acrylic
IP12=K-12 Prismatic
Polycarbonate
1
=Bat Wing
KSH25
Distribution
93=Prismatic
Tempered Glass
Ballast LE3=Energy
Saving Ballast for use with T12 Lamp
Electronic
2
Ballast EB51=(1) Ballast
for use with T5 Lamp
EB52=(2) Ballasts
for use with T5 Lamp
EB81=(1) Ballast
for use with T8 Lamp
EB82=(2) Ballasts
for use with T8 Lamp
EB21=(1) Ballast
for use with T12 Lamp
EB22=(2) Ballasts
for use with T12Lamp
EBX1=(1) Ballast
for use with Biaxial Lamp
EBX2=(2) Ballasts
for use with Biaxial Lamp
Door/Finish Options Blank=Standard, CRS
with baked white finish
SSN=Stainless Steel
Door/ Brushed 304 Finish
SSP=Stainless Steel
Door/ Polyester Powder Coat Finish
ALP=Aluminum Door/
Polyester Powder Finish
ALX=Extruded
Aluminum Door/Clear Anodized Finish
ALXP= Extruded
Aluminum Door/Polyester Powder Finish
Accessories
(Order Separately)
MFCF24-2FT=Mounting
MFCF24-4FT=Mounting
Options EBP=Emergency
Battery Pack
GLR=Fuse and
Holder
RIF=Radio
Frequency Interference Filter
TAD=Top Access
Door
Housing Options SHN=Stainless
Steel, Brushed 304 Finish
3
SHP=Stainless
Steel, Polyester Powder
3
Finish
ALH=Aluminum,
Polyester Powder Finish
Frame (not required for installation)
Frame (not required for installation)
4
1480
COOPER LIGHTING
Notes: For additional options, consult your Cooper Lighting Representative. Specifications and Dimensions subject to change without notice. Electronic ballast may cause interference with other electronic devices. If interference occurs move the device away from the product or plug/connect into a different circuit/outlet.
1
The KSH25 provides improved visual performance and wide angle distribution. This lens has an integral prism pattern designed so that
prisms face the lamp cavity and still supply superior photometrics. Highly recommended for all high tech manufacturing environments.
2
For specific electronic ballast, specify brand and catalog number. 3Not rated for 200 PSI hose down. 4Contact your Cooper Lighting
Representative for dimensional details.