TALON
VERSATILE PERFORMANCE
Talon’’s ingenious blend of performance and 
versatility allows application specific 
illumination by way of fourteen [14] high 
efficiency, field rotatable optical systems. 
Offered with the unrivaled Spill Light Eliminator 
[SL] optic for areas requiring strict light 
trespass control, and the premier Automotive 
Front Row [AF] optic for precisely illuminated 
automotive dealership front row displays. 
Flat glass or sag, vertical lamp or horizontal, 
segmented optic or formed, Talon offers a 
myriad of optical solutions to satisfy exacting 
application requirements. 
AREA LUMINAIRE
TABLE OF CONTENTS
Performance + Versatility.................................3
Quality + Durability .........................................5
Control + Efficiency .........................................7
Specification Features ....................................11
Options + Accessories ...................................13
Photometrics..................................................15
Ordering Information [TMU + TLU].................17
 

SITE + PARKING | ROADWAY | PATH OF EGRESS
IMPENETRABLE FORM
Coupling precise mechanical design with 
premium quality materials, the Talon site light 
is constructed to sustain the rigors of outdoor 
operation. Thick wall die-cast aluminum 
construction and channel set silicone gasketing 
form an impenetrable IP65 barrier optimizing 
optical efficiency and fixture longevity in the 
harshest of environments.
INNOVATIVE FOREFRONT
Forward Leaning— two words that describe 
Streetworks’ product development process 
and relentless commitment to providing 
progressive solutions for emerging market 
trends. Regardless of the ordinance governing 
your site—spill control, emergency egress, 
energy efficiency or curfew compliance, the 
Talon offers progressive features to address 
rigorous regulatory needs.
 

3 
4
PERFORMANCE + VERSATILITY
MAXIMIZE SITE UNIFORMITY
Add sparkle to your site and maximize 
pole spacings with sag glass optical 
systems offered in both cutoff and 
semi-cutoff configurations. 
For applications mandating full cutoff, 
choose from a complete offering of flat 
glass vertical lamp solutions. The vertically 
lamped family of optical systems 
minimizes light levels directly below 
the luminaire while increasing lateral 
illumination, maximizing overall site 
uniformity. Available in Type III, Area 
Round, Area Square, Type IV and 
Automotive Front Row [TLU only] 
distributions.
OPTICAL VERSATILITY
Never before has a single luminaire 
supported this magnitude of optical 
choices, touting four [4] distinct families 
of optical assemblies, all with compelling 
performance. Hydroformed, segmented, 
vertical and specialty application optical 
systems allow finely tuned site lighting 
solutions with unprecedented levels of 
uniformity and control.
 

LEADING SPILL CONTROL
The Spill Light Eliminator [SL] optic is the 
industry leader in effective spill light 
control, eliminating light beyond one [1] 
mounting height behind the pole with no 
sacrifice in forward illumination. Used 
along site perimeters and property lines, 
the Spill Light Eliminator keeps the light 
inside and the darkness out.
ROTATIONAL FLEXIBILITY
Maintain uniform site spacing and 
fixture orientation with rotatable optical 
assemblies. All optics are capable of 
rotating in 90° increments allowing for 
manipulation of distribution orientation 
independent of fixture position.
DARK SKY FRIENDLY
For applications requiring dark sky friendly 
solutions, look to full cutoff flat glass 
optical assemblies providing focused 
illumination with zero uplight and minimal 
high angle illumination while retaining 
superior uniformity. Available in 
hydroformed or segmented Type II, III, IV, 
V and SL distributions.
OPTICAL SOLUTIONS AS DIVERSE AS THE ENVIRONMENTS THEY ILLUMINATE.
Exterior lighting requirements continue to grow more stringent with added emphasis on light control and system efficiency. Whether the goal of your
site lighting design is safety, general illumination or highlighting prominent features, Talon offers application-specific optical solutions that provide the
highest level of photometric performance and control.
GET NOTICED
Accel Optics, the Talon’s family of 
automotive reflector solutions specialize in 
focused front row product displays that 
engage the customer, general merchandise 
lighting that creates an inviting dealership 
appearance emanating safety and security, 
and perimeter lighting that precisely 
frames the automotive dealership lot.
NOTE: In Flat Glass configurations only.
 

5 
6
QUALITY + DURABILITY
DURABLE CAST CONSTRUCTION
Low-copper alloy die-cast aluminum 
construction offers corrosion resistance 
while precise tolerance control ensures 
tight nesting of the door and housing. 
Combining heat extracting reveal channels 
with independent optical and electrical 
chambers that isolate heat producing 
sources, the Talon’s housing design is 
both functionally relevant and aesthetically 
pleasing.
TOOLLESS ENTRY
Invisibly integrated door retaining latches 
allow for a consistent outward aesthetic 
while providing maintenance-friendly, 
toolless entry into the optical and 
electrical chambers. The corrosionresistant stainless spring steel latch 
and door receiver pin create an audible 
engagement confirming secure door 
closure and fixture sealing.
RIGID OPTICAL CONSTRUCTION
A commitment to optical research and 
precision build quality result in unequaled 
levels of performance and repeatability. 
A rigid box enclosure shields segmented 
optical facets on all sides from performance 
degrading damage while each facet bank is 
secured to both the top and bottom of the 
enclosure providing repeatable facet 
orientation relative to light center. 
PREMIUM MATERIALS
Superior optical design and a commitment 
to premium 95% reflective sheet aluminum 
make Talon’s segmented reflector family 
the benchmark of optical excellence. 
Reflector facets are flat and unobstructed 
by rivets or other means of attachment 
which may cause streaks or striations in 
the light distribution. First class 
construction and attention to detail 
ensure dependable performance in 
every installation.
INGRESS PROTECTION
“IP” stands for Ingress Protection and is a 
rating system recognized internationally 
as the standard for electrical products 
and other related technologies. The two 
numbers proceeding the “IP” individually 
callout the fixture's protection rating 
against moisture and airborne  
particulates. The channel set silicone 
gasketing system incorporated in Talon 
is IP65 certified. Dust, insects and 
moisture simply have no chance of 
penetrating the outer enclosure.
 

CONFIDENCE-INSPIRING QUALITY BEYOND THE SUM OF ITS PARTS.
From the stainless steel hinges to the rugged housing, every detail of the Talon construction is precisely designed with industry leading craftsmanship.
Heavy-wall die-cast aluminum construction, premium TGIC [triglycidyl isocyanurate] polyester powder coat paint and an IP65 rated optical cavity ensure
Talon can endure the harshest environments.
FINISH OPTIONS
Streetworks’ premium polyester powder coatings are enhanced 
TGIC based coatings formulated to withstand extended outdoor 
exposure. The powders are designed not only to be functional, but 
decorative, combining good film appearance with excellent mechanical 
and exterior exposure qualities. Formulated with properties similar to 
a standard TGIC, the improved weathering characteristics of premium 
TGIC result from the integration of a new polyester resin technology. 
These coatings consistently display at least twice the gloss retention 
of standard TGIC materials in both weatherometer and QUV testing, 
making them ideal for outdoor lighting fixtures and poles. Applied to 
a nominal 2.5 mil thickness, Talon’s six (6) standard finishes offer 
superior protection against fade and wear.
GREY [AP]
WHITE [WH]
BLACK [BK]
DARK PLATINUM [DP]
BRONZE [BZ]
GRAPHITE METALLIC [GM]
100
96
92
88
84
Percentage To Original
0 6 12 18 24
Color Retention Over Time
Months Exposure
TGIC    Streetworksʼ Premium 
 

LUMINAIRE CLASSIFICATION
The IESNA’’s revised Luminaire Classification System 
[TM15-07 revised] creates a new basis of measurement 
for site lighting visibility and adjacent property 
interaction. This technical memorandum subdivides 
the luminaire distribution into smaller angular zones 
and subzones to more clearly represent how much 
light is emitted at various angles. The values for each 
subzone give an indication of the appropriate use for 
the luminaire within an application. For dark sky 
sensitive areas, the uplight component tells how 
much the luminaire will contribute to sky glow. 
For applications with strict light trespass regulations, 
the back light portion of the distribution helps 
determine how much light will reach neighboring 
properties. Talon reflector assemblies keep light on 
task by contributing as little as 0.0% total upward 
illumination and 0.8% total backlight. 
Forward Light
Forward Light Low [FL] 
Forward Light Mid [FM] 
Forward Light High [FH] 
Forward Light Very High [FVH]
Back Light
Back Light Low [BL] 
Back Light Mid [BM] 
Back Light High [BH] 
Back Light Very High [BVH]
Uplight
Uplight Low [UL] 
Uplight High [UH]
NEIGHBORHOOD AND DARK SKY FRIENDLY
National organizations work to educate the general public on best lighting practices in order to minimize light trespass, reduce sky-glow and improve 
nighttime visibility through glare reduction. Experts understand the visual system adapts to surrounding ambient conditions, spurring a move from 
universal light level recommendations to a set of custom tailored guidelines for each task based on an application’s lighting zone. When surrounding 
conditions are dim, lower levels of light are able to be detected more easily. In these environments, high light level applications can be a source of 
discomfort and glare. Careful selection and placement of luminaires eliminates glare and creates a comfortable nighttime environment. Talon’s 
assortment of specialty light control optical assemblies combined with a wide array of internal or external house-side shields provide the perfect 
solution for every application.
Uplight
180°
UH
100° 100°
UL UL
90° 90°
BVH FVH
80° 80°
BH FH
60° 60°
Back Forward
BM FM
BL FL
30° 30°
0°
[nadir]
Glare
Light Trespass
Uniform Task Illumination
Property
Line
 

STEPPING UP TO THE CHALLENGE.
As visual research advances so too the core understanding of how light interacts with surrounding communities and nocturnal environments. 
Utilizing this knowledge, Federal programs, national organizations and industry leaders institute guidelines for illuminating an area safely and 
securely while reducing energy, eliminating spill light and minimizing glare. Talon steps up to the challenge, offering innovative solutions to regulatory 
compliance issues.
ENERGY EFFICIENCY 
With the Federal Energy Independence and Security Act effective January 1, 2009, states are rapidly adopting energy legislation limiting the use of probe 
start sources in favor of higher efficiency options. Pulse start technology is being embraced for its efficacy, extended life, high lumen maintenance, and 
color consistency. The increased color rendering of a pulse start lamp improves visibility and heightens the overall safety and security of the site. Higher 
lumen maintenance levels reduce the number of fixtures needed to achieve a consistent light level over the fixture’’s installed life. Initial savings are 
compounded by decreased energy consumption and less frequent maintenance requirements. By supporting a full array of both horizontal and vertical 
lamp distributions, Talon offers the broadest selection of energy saving pulse start solutions. 
CURFEW COMPLIANCE
Certain regulatory documents incorporate energy saving measures beyond standard source efficacy, including curfew regulations calling for close 
of business site lighting power reduction. When alternating luminaires are turned off to accomplish the reduction, site lighting uniformity is greatly 
reduced, compromising visibility and the feeling of security. The Talon Hi/Low [HL] option enables curfew compliance through an integrated 
dimming relay internal to the housing that reduces power while closely maintaining critical-to-safety site lighting uniformity levels. 
120
Lumen Output Over Time
100
80
60
40
Lumen Output [In Thousands]
20
0
0 2000 4000 6000 8000 10000
12000 14000 1800016000
Hours of Operation [4000 hours ~ 1 year]
750W Pulse Start MH 1000W Probe Start MH
Alternating Fixture Switching
Hi/Low Dimming
 

11 
12
SPECIFICATION FEATURES
MOUNTING
Extruded 8" [TMU Talon Medium] or 10 
1/2" [TLU Talon Large] aluminum arm 
includes internal bolt guides allowing 
for easy positioning of fixture during 
installation to pole or wall surface. 
Standard single carton packaging of 
housing, square pole arm and round 
pole adapter for contractor friendly 
arrival of product on site.
CONSTRUCTION
Heavy-wall, die-cast low-copper alloy 
aluminum construction with integral 
reveal channels along top surface of 
housing to promote heat extraction and 
prolong electrical component life. Internal 
cast-in wall separates optical and electrical 
chambers, allowing components to operate 
cooler. One-piece heavy-wall, die-cast 
aluminum door frame with integral cast-in 
gasket channel seals optical chamber to an 
IP65 rating. Stainless steel latches and 
hinges.
OPTICAL SYSTEMS
Choice of fourteen [14] high efficiency 
optical systems utilizing horizontal and 
vertical lamp orientations, including five [5] 
optional high efficiency segmented optical 
systems constructed of premium 95% 
reflective anodized aluminum sheet. 
Optical segments are rigidly mounted 
inside a thick gauge aluminum housing for 
superior protection. All segment faces are 
clean of rivet heads, tabs or other means 
of attachment which may cause streaking 
in the light distribution. Standard with 
mogul-base socket for HPS and 
175-1000W MH. Standard with 
medium-base socket for 150W MH and 
below. All optical modules feature quick 
disconnect wiring plugs and are field 
rotatable in 90° increments.
ELECTRICAL
TMU offered standard with ballast and 
related electrical componentry hard 
mounted to die-cast housing for optimal 
heat transfer and improved operating 
efficiency. TMU optional and TLU standard, 
electrical componentry mounted to a 
swing-down galvanized steel power tray 
with integral handle. Electrical disconnects 
allow tray to be completely removed from 
the housing providing ample hand and 
tool room for attachment of fixture during 
installation.
Lamp Standard Door 70-200W 250-400W Lamp 250-1000W
Distribution Orientation Configuration Lens Type Lens Type Orientation Lens Type 
2F
Horizontal Recessed Flat/Sag Flat/Sag Horizontal Flat/Sag
2S Horizontal Recessed Flat/Sag Flat/Sag Horizontal Flat/Sag 
3F Horizontal Recessed Flat/Sag Flat/Sag Horizontal Flat/Sag 
3S Horizontal Recessed Flat/Sag Flat/Sag Horizontal Flat/Sag 
4F Horizontal Recessed Flat/Sag Flat/Sag Horizontal Flat/Sag 
4S Horizontal Recessed Flat/Sag Flat/Sag Horizontal Flat/Sag 
5F Horizontal Recessed Flat/Sag Flat/Sag Horizontal Flat/Sag 
5S Horizontal Recessed Flat/Sag Flat/Sag Horizontal Flat/Sag 
SL Horizontal Recessed Flat/Sag Flat/Sag Horizontal Flat/Sag 
AR Vertical Deep Flat/Sag Sag Vertical Flat/Sag 
AS Vertical Deep Flat/Sag Sag Vertical Flat/Sag 
3V Vertical Deep Flat/Sag Sag Vertical Flat/Sag 
4V Vertical Deep Flat/Sag Sag Vertical Flat/Sag 
AF Horizontal Recessed Flat/Sag Flat/Sag Vertical Flat/Sag
TALON MEDIUM [TMU] TALON LARGE [TLU]
 

FINISH
Housing and arm finished in a 5 stage 
premium TGIC polyester powder coat 
paint, 2.5 mil nominal thickness for 
superior protection against fade and 
wear. Standard colors include black, 
bronze, grey, white, dark platinum, 
and graphite metallic.
MOUNTING CONFIGURATIONS
Talon is available in seven [7] unique luminaire mounting configurations.
NOTE: In Flat Glass configurations only.
DRILLING PATTERNS 
Type “M” Wall Mount
Certifications
GM
Graphite Metallic
WH
White
DP
Dark Platinum
BZ
Bronze
BK
Black
AP
Grey
Wall Mount Arm Mount Single
E.P.A. 
TMU
Recessed Door 1.22 
Deep Door 1.45
TLU 2.51
Arm Mount 2 @ 180° 
E.P.A. 
TMU
Recessed Door 2.44 
Deep Door 2.90
TLU 5.02
Arm Mount 2 @ 90° 
E.P.A. 
TMU
Recessed Door 2.44 
Deep Door 2.90
TLU 5.02
Arm Mount 3 @ 120° 
E.P.A. 
TMU
Recessed Door 3.23 
Deep Door 3.92
TLU 6.85
Arm Mount 3 @ 90° 
E.P.A. 
TMU
Recessed Door 3.23 
Deep Door 3.92
TLU 6.85
Arm Mount 4 @ 90° 
E.P.A. 
TMU
Recessed Door 3.63 
Deep Door 4.43 
TLU 7.77
IP65 Rated   
CSA Listed
U.L. 1598 Listed
25°C Ambient
ISO 9001
2 5/16"
[59mm]
3/4" [20mm] 
dia. hole
2 7/16" [124mm]
4 7/8" [124mm]
[2] 5/8" [16mm] 
dia. holes 
6 1/2"
[165mm]
8"
[203mm]
12"
[305mm]
4 7/8"
[124mm]
10 1/2"
[267mm]
9/16" [14mm]
Dia. Hole [4]
 

[Arm Mount] [WM]
13 
14
OPTIONS + ACCESSORIES
ARM MOUNT
Standard 8" [TMU] or 10 1/2" [TLU] 
extruded aluminum arm features internal 
bolt guides for twin support rods. Round 
pole mounting accommodated by utilizing 
provided round pole adapter between the 
fixture arm and pole shaft. 
EXTERNAL MAST ARM ADAPTER [MS] 
Cast aluminum mast arm adapter secures 
fixture head to nominal 2" [2 3/8" O.D. pipe 
size] horizontal steel tenon arm. Adapter 
casting slip fits over tenon arm and is 
secured via two [2] stainless steel bolts. 
WALL BRACKET [WM] 
Wall bracket secured to wall via four [4] lag 
bolts [lag bolts supplied by other]. Wall 
bracket kit includes 1/2" thick steel adapter 
plate, a 8" [TMU] or 10 1/2" [TLU] machined 
extruded aluminum arm and two [2] fixture 
support rods. 
TENON ADAPTER
Tenon adapters available to slip fit over poles 
equipped with nominal 2" pipe size steel tenon 
[2 3/8" O.D., 4" length] or nominal 3" pipe size 
steel tenons [3 1/2" O.D., 5" length]. Adapter 
secures to tenon via six [6] stainless steel 
bolts. For complete configuration availability, 
see Tenon Adapters on page 14.
POLYCARBONATE VANDAL SHIELD [V] 
Internally mounted 3/16" thick molded 
polycarbonate lens, treated with UV inhibitor 
to discourage the gradual discoloration that 
results from exposure to sunlight and UV 
radiating sources.
QUARTZ RESTRIKE [Q + E] 
Optional quartz restrike [Q] energizes auxiliary 
quartz lamp upon power reactivation and 
extinguishes once HID lamp re-ignites. 
Quartz restrike with time delay [E] adds 
cold start activation. 
PHOTOCONTROL RECEPTACLE [4] 
Fixtures available with gasketed photocontrol 
receptacle for mounting a standard NEMA 
photocontrol [ordered separately]. Medium 
housing also available with a button-style 
photocontrol [P].
INTERNAL HOUSE-SIDE SHIELD [B] 
Internal house-side shield reduces light 
concentration behind the pole while 
maintaining street side efficiency. Internal 
house-side shields available on Type II, III, IV 
and AF distributions. 
EXTERNAL HOUSE-SIDE SHIELD
[MA1213-XX + MA1214-XX] 
External house-side shield provides sharp 
cutoff behind the pole and shields the lamp 
from direct view. Mounted to the door frame 
via double-sided VHB adhesive [TMU] or three 
[3] stainless steel fasteners [TLU]. Rotatable in 
90° increments, the external house-side shield 
provides industry leading glare and spill light 
control.
[MS]
 

OPTIONS
[Factory installed and shipped complete with luminaire]
Electrical 
1=Single Fuse [120, 277 or 347V] 
2=Double Fuse [208, 240 or 480V] 
3=3 Place Terminal Block 
4=NEMA Twistlock Photocontrol Receptacle 
E=Quartz Restrike w/Delay [Also Strikes at Cold Start] 
H=Plug-in Starter Receptacle 
HL=Hi/Low Dimming [Vertical Optics Only] 
P=Button Type Photocontrol [TMU Only] 
Q=Quartz Restrike [Hot Restrike Only] 
R=Removable Power Tray [Standard on TLU] 
U=U.L. Listed
Shields + Doors 
B=Internal House Side Shield 
DD=Deep Door [TMU Only] 
V=Polycarbonate Vandal Shield [TMU Only]
Mounting 
DM=Direct Mount for Round or Square Pole  
DW=Direct Wall Mount Kit 
MS=External Mast Arm Adapter [TMU Only] 
WM=Wall Bracket with Arm
ACCESSORIES
[Field installed and shipped independent of luminaire]
Electrical 
OA/RA1016=NEMA Photocontrol [105-285V] 
OA/RA1027=NEMA Photocontrol [480V] 
OA/RA1201=NEMA Photocontrol [347V] 
OA/RA1013=Shorting Cap
Tenon Adapters 
MA1010-XX=Single Tenon Adapter for 3 1/2" O.D. Tenon 
MA1011-XX=2 @ 180° Tenon Adapter for 3 1/2" O.D. Tenon 
MA1012-XX=3 @ 120° Tenon Adapter for 3 1/2" O.D. Tenon 
MA1013-XX=4 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon 
MA1014-XX=2 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon 
MA1015-XX=2 @ 120° Tenon Adapter for 3 1/2" O.D. Tenon 
MA1016-XX=3 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon 
MA1017-XX=Single Tenon Adapter for 2 3/8" O.D. Tenon 
MA1018-XX=2 @ 180° Tenon Adapter for 2 3/8" O.D. Tenon 
MA1019-XX=3 @ 120° Tenon Adapter for 2 3/8" O.D. Tenon 
MA1045-XX=4 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon 
MA1048-XX=2 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon 
MA1049-XX=3 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon
Shields 
MA1213-XX=External House-side Shield Kit [TMU Only] 
MA1214-XX=External House-side Shield Kit [TLU Only]
DEEP DOOR [DD]
Medium housing vertically lamped optics are 
shipped standard with Deep Door. For sites 
combining horizontal and vertical optics, specify 
the Deep Door [DD] option on horizontal lamp 
fixtures to maintain a uniform outward aesthetic. 
Reflector shifted downward toward the lens to 
maintain optimal photometric performance 
[TMU only].
Horizontal optic in recessed door position.
[MA1213 + MA1214]
[B]
[4]
[Tenon Adapter]
[V]
[Q + E]
Horizontal optic in deep door position.
 

15 
16
PHOTOMETRICS [Complete IES files available at www.cooperlighting.com]
FOOTCANDLE TABLE
Select mounting height and read across for 
footcandle values of each isofootcandle 
line. Distance in units of mounting height.
Mounting Footcandle Values for 
Height Isofootcandle Lines
AB C D E
100W [3F]
15' 3.40 1.70 0.86 0.34 0.17
20' 2.00 1.00 0.50 0.20 0.10
25' 1.28 0.64 0.32 0.13 0.06
150W [4V]/175W [3V/AS] 
15' 1.70 0.85 0.34 0.17 --
20' 1.00 0.50 0.20 0.10 --
25' 0.64 0.32 0.13 0.06 --
TMU10SXX3FF
100-Watt HPS 
9,500-Lumen Clear Lamp 
Type III Formed 
Flat Glass
TMU15SXX4VS
150-Watt HPS 
16,000-Lumen Clear Lamp 
Type IV Vertical 
Sag Glass
TMU17MXX3VF 
175-Watt MH 
14,000-Lumen Clear Lamp 
Type III Vertical 
Flat Glass
TMU17MXXASF
175-Watt MH 
14,000-Lumen Clear Lamp 
Area Square 
Flat Glass
FOOTCANDLE TABLE
Select mounting height and read across for 
footcandle values of each isofootcandle 
line. Distance in units of mounting height.
Mounting Footcandle Values for 
Height Isofootcandle Lines
AB C D E
250W [5F/SL]/400W [3S]
25' 2.88 1.44 0.72 0.29 0.14
30' 2.00 1.00 0.50 0.20 0.10
35' 1.46 0.73 0.37 0.15 0.07
250W [AS] 
25' 1.44 0.72 0.29 0.14 --
30' 1.00 0.50 0.20 0.10 --
35' 0.73 0.37 0.15 0.07 --
TMU25SXX5FF
250-Watt HPS 
30,000-Lumen Clear Lamp 
Type V Formed 
Flat Glass
TMU25SXXASS
250-Watt HPS 
30,000-Lumen Clear Lamp 
Area Square 
Sag Glass
TMU25MXXSLF
250-Watt MH 
20,500-Lumen Clear Lamp 
Spill Light Eliminator 
Flat Glass
TMU40MXX3SF
400-Watt MH 
36,000-Lumen Clear Lamp 
Type III Segmented 
Flat Glass
FOOTCANDLE TABLE
Select mounting height and read across for 
footcandle values of each isofootcandle 
line. Distance in units of mounting height.
Mounting Footcandle Values for 
Height Isofootcandle Lines
AB C D E
400W [3V/4V/5S/AR]
20' 3.00 1.50 0.75 0.30 0.15
25' 2.00 1.00 0.50 0.20 0.10
30' 1.38 0.69 0.34 0.13 0.06
TMU40MXX3VS 
400-Watt MH 
36,000-Lumen Clear Lamp 
Type III Vertical 
Sag Glass
TMU40MXX4VS
400-Watt MH 
36,000-Lumen Clear Lamp 
Type IV Vertical 
Sag Glass
TMU40MXX5SF
400-Watt MH 
36,000-Lumen Clear Lamp 
Type V Segmented 
Flat Glass
TMU40MXXARF
400-Watt MH 
36,000-Lumen Clear Lamp 
Area Round 
Flat Glass
FOOTCANDLE TABLE
Select mounting height and read across for 
footcandle values of each isofootcandle 
line. Distance in units of mounting height.
Mounting Footcandle Values for 
Height Isofootcandle Lines
AB C D E
400W [2F/3VB/5F/AR]
25' 2.88 1.44 0.72 0.29 0.14
30' 2.00 1.00 0.50 0.20 0.10
35' 1.46 0.73 0.37 0.15 0.07
TMU40SXX2FF
400-Watt HPS 
50,000-Lumen Clear Lamp 
Type II Formed 
Flat Glass
TMU40SXX3VSB
400-Watt HPS 
50,000-Lumen Clear Lamp 
Type III Vertical Sag Glass 
Internal House-side Shield
TMU40SXX5FF
400-Watt HPS 
50,000-Lumen Clear Lamp 
Type V Formed 
Flat Glass
TMU40SXXARS
400-Watt HPS 
50,000-Lumen Clear Lamp 
Area Round 
Sag Glass
ABCDE
AB C DE
ABCD
AB CD
AB CD
ABCDE
AB CD
ABCDE
AB C DE
ABCDE
ABCDE
AB CDE
ABCDE
ABCDE
ABCDE
 

PHOTOMETRICS [Complete IES files available at www.cooperlighting.com]
FOOTCANDLE TABLE
Select mounting height and read across for 
footcandle values of each isofootcandle 
line. Distance in units of mounting height.
Mounting Footcandle Values for 
Height Isofootcandle Lines
AB C D E
400W [3F/4F/3V]
25' 2.88 1.44 0.72 0.29 0.14
30' 2.00 1.00 0.50 0.20 0.10
35' 1.46 0.73 0.37 0.15 0.07
400W [AR] 
25' 1.44 0.72 0.29 0.14 --
30' 1.00 0.50 0.20 0.10 --
35' 0.73 0.37 0.15 0.07 --
TLU40SXX3VF
400-Watt HPS 
50,000-Lumen Clear Lamp 
Type III Vertical 
Flat Glass
TLU40MXX3FF 
400-Watt MH 
36,000-Lumen Clear Lamp 
Type III Formed 
Flat Glass
TLU40SXX4FF 
400-Watt HPS 
50,000-Lumen Clear Lamp 
Type IV Formed 
Flat Glass
TLU40MXXARS
400-Watt MH 
36,000-Lumen Clear Lamp 
Area Round 
Sag Glass
FOOTCANDLE TABLE
Select mounting height and read across for 
footcandle values of each isofootcandle 
line. Distance in units of mounting height.
Mounting Footcandle Values for 
Height Isofootcandle Lines
AB C D E
400W [AR]/1000W [3F]
25' 2.88 1.44 0.72 0.29 0.14
30' 2.00 1.00 0.50 0.20 0.10
35' 1.46 0.73 0.37 0.15 0.07
1000W [SL/3V] 
25' 7.20 2.88 1.44 0.72 0.29
30' 5.00 2.00 1.00 0.50 0.20
35' 3.65 1.46 0.73 0.37 0.15
TLU40SXXARF
400-Watt HPS 
50,000-Lumen Clear Lamp 
Area Round 
Flat Glass
TLU40SXXSLF
400-Watt HPS 
50,000-Lumen Clear Lamp 
Spill Light Eliminator 
Flat Glass
TLU91SXX3FF
1000-Watt HPS 
135,000-Lumen Clear Lamp 
Type III Formed 
Flat Glass
TLU91MXX3VF
1000-Watt MH 
110,000-Lumen Clear Lamp 
Type III Vertical 
Flat Glass
FOOTCANDLE TABLE
Select mounting height and read across for 
footcandle values of each isofootcandle 
line. Distance in units of mounting height.
Mounting Footcandle Values for 
Height Isofootcandle Lines
AB C D E
1000W [3V-EHS (HPS)/5F]
25' 2.88 1.44 0.72 0.29 0.14
30' 2.00 1.00 0.50 0.20 0.10
35' 1.46 0.73 0.37 0.15 0.07
1000W [3V-EHS (MH)/4VB] 
25' 7.20 2.88 1.44 0.72 0.29
30' 5.00 2.00 1.00 0.50 0.20
35' 3.65 1.46 0.73 0.37 0.15
TLU91MXX3VFEHS
1000-Watt MH 
110,000-Lumen Clear Lamp 
Type III Vertical Flat Glass 
External House-side Shield
TLU91SXX3VFEHS
1000-Watt HPS 
135,000-Lumen Clear Lamp 
Type III Vertical Flat Glass 
External House-side Shield
TLU91MXX4VFB
1000-Watt MH 
110,000-Lumen Clear Lamp 
Type IV Vertical Flat Glass 
House-side Shield
TLU91SXX5FF
1000-Watt HPS 
135,000-Lumen Clear Lamp 
Type V Formed 
Flat Glass
FOOTCANDLE TABLE
Select mounting height and read across for 
footcandle values of each isofootcandle 
line. Distance in units of mounting height.
Mounting Footcandle Values for 
Height Isofootcandle Lines
AB C D E
1000W [4V/SL/AS]
25' 2.88 1.44 0.72 0.29 0.14
30' 2.00 1.00 0.50 0.20 0.10
35' 1.46 0.73 0.37 0.15 0.07
1000W [AF] 
25' 30.00 10.00 3.00 1.00 0.20
27' 25.50 8.50 2.55 0.85 0.17 
30' 20.70 6.90 2.07 0.69 0.14
TLU91SXX4VFB 
1000-Watt HPS 
135,000-Lumen Clear Lamp 
Type IV Vertical Flat Glass 
Internal House-side Shield
TLU91MXXSLF 
1000-Watt MH 
110,000-Lumen Clear Lamp 
Spill Light Eliminator 
Flat Glass
TLU91MXXASF
1000-Watt MH 
110,000-Lumen Clear Lamp 
Area Square 
Flat Glass
TLU91MXXAFF
1000-Watt MH 
110,000-Lumen Clear Lamp 
Automotive Front Row 
Flat Glass
ABCDE
ABC DE
AB C DE
ABC ED
ABC DE
ABC DE
AB C D
ABCDE
AB CDE
ABC D E
ABC D F
ABCDE
ABCDE
ABCD E
ABCDF
 

17 
18
TMU TALON MEDIUM
ORDERING INFORMATION
SAMPLE NUMBER: TMU40SWW3SF
VOLTAGE 
2=120V 
0=208V 
4=240V 
7=277V 
8=480V 
9=347V 
N=Multi-Tap 
wired 277V
W=Multi-Tap 
wired 120V
V=Multi-Tap 
wired 240V
BALLAST TYPE 
C=CWI 
H=Reac./HPF 
K=10KV CWA 
N=Hi. Reac./NPF 
P=Hi. Reac./HPF 
R=Reac./NPF 
W=CWA
DISTRIBUTION 
Horizontal Lamp 
2F=Type II Formed 
2S=Type II Segmented 
3F=Type III Formed 
3S=Type III Segmented 
4F=Type IV Formed 
4S=Type IV Segmented 
5F=Type V Formed 
5S=Type V Segmented 
SL=Spill Light Eliminator 
AF=Automotive Front Row 
Vertical Lamp 
3V=Type III Vertical
5
4V=Type IV Vertical
5
AR=Area Round
5
AS=Area Square
5
LENS TYPE 
F=Flat Glass 
S=Sag Glass
COLOR
[add as suffix 
/must specify]
WH=White 
BK=Black 
AP=Grey 
BZ=Bronze 
DP=Dark Platinum 
GM=Graphite Metallic
PRODUCT 
FAMILY
1
TMU=Talon
Site 
Medium
LAMP TYPE 
S=High 
Pressure 
Sodium
R=Super Metal
Halide
M=Metal 
Halide
P=Pulse Start
Metal Halide
LAMP 
WATTAGE
2
70=70W 
10=100W 
15=150W 
17=175W 
20=200W 
25=250W 
32=320W
3, 4
35=350W
3, 4
40=400W
4
24=250/400W
wired 250W
42=250/400W
wired 400W
OPTIONS [add as suffix] 
1=Single Fuse [120, 277 or 347V]
6
2=Double Fuse [208, 240 or 480V]
6
3=Three Place Terminal Block  
4=NEMA Twistlock Photocontrol Receptacle 
B=Internal House-side Shield
7
DD=Deep Door  
DM=Direct Mount for Round or Square Pole  
DW=Direct Wall Mount Kit 
E=Quartz Restrike w/Delay [Also Strikes at Cold Start]
8
H=Plug-in Starter Receptacle 
HL=Hi/Low Dimming
9
L=Lamp Included 
MS=External Mast Arm Adapter 
P=Button Type Photocontrol [120, 208, 240 or 277V]
6
Q=Quartz Restrike [Hot Restrike Only]
8
R=Removable Power Tray 
U=U.L. Listed 
V=Polycarbonate Vandal Shield 
WM=Wall Bracket with 8" Arm
OPTIONS + ACCESSORIES [must be ordered in alphanumeric order]
ACCESSORIES [order separately/replace XX with color designation]
OPTIONS + 
ACCESSORIES
[See Below]
NOTES: 1 8" arm and round pole adapter included with fixture. 2 Standard with mogul-base socket for HPS and 100-400W MH. Standard with medium-base socket for 70W MH. 3 320/350W Pulse Start Metal Halide
lamp only. 4 Requires reduced envelope lamp. 5 Vertical lamp optics ship standard with deep door. Flat glass not available for 250W—400W. 6 Must specify voltage. 7 House-side shield not available on 5S, 
5F, AS, AR and SL optics. 8 Quartz options not available with SL and AF optics. 9 Requires vertical lamp orientation. Provides 24V low voltage leads used in dimming controls. 10 Specifications and 
dimensions subject to change without notice.
Lamp Type Wattage
Metal Halide
175, 250, 400W
Pulse Start Metal Halide
70, 100, 150, 175, 200, 250, 320, 350, 400W
Super Metal Halide
175, 250, 400W
High Pressure Sodium 70, 100, 150, 250, 400W
DIMENSIONS
WATTAGE TABLE
IP65 Rated
25° C Ambient Temperature
U.L. 1598 Listed
CSA Listed
ISO 9001
FCO [Full Cutoff] Flat Glass Only
CERTIFICATIONS
STANDARD COLORS
GM
Graphite Metallic
WH
White
DP
Dark Platinum
BZ
Bronze
BK
Black
AP
Grey
DRILLING PATTERNS
TYPE “M” WALL MOUNT
Effective Projected Area
Recessed Door w/o Arm: 0.79
Deep Door w/o Arm: 1.02
8" Arm: 0.43
EPA
Approximate Net Weight
Recessed Door 47 lbs. [21.79 kgs.]
Deep Door    52 lbs. [23.63 kgs.]
SHIPPING DATA
OA/RA1016=NEMA Photocontrol [105-285V] 
OA/RA1027=NEMA Photocontrol [480V] 
OA/RA1201=NEMA Photocontrol [347V] 
OA/RA1013=Shorting Cap 
MA1010-XX=Single Tenon Adapter for 3 1/2" O.D. Tenon 
MA1011-XX=2 @ 180° Tenon Adapter for 3 1/2" O.D. Tenon 
MA1012-XX=3 @ 120° Tenon Adapter for 3 1/2" O.D. Tenon 
MA1013-XX=4 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon 
MA1014-XX=2 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon 
MA1015-XX=2 @ 120° Tenon Adapter for 3 1/2" O.D. Tenon 
MA1016-XX=3 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon 
MA1017-XX=Single Tenon Adapter for 2 3/8" O.D. Tenon 
MA1018-XX=2 @ 180° Tenon Adapter for 2 3/8" O.D. Tenon 
MA1019-XX=3 @ 120° Tenon Adapter for 2 3/8" O.D. Tenon 
MA1045-XX=4 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon 
MA1048-XX=2 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon 
MA1049-XX=3 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon 
MA1213-XX=External House-side Shield Kit [EPA=0.38]
8"
[203mm]
11 7/8"
[302mm]
8"
 [203mm]
16 1/4" [412mm]
1 3/4"
[45mm]
23 1/4" [590mm]
2 5/16"
[59mm]
3/4" [20mm] 
dia. hole
2 7/16" [124mm]
4 7/8" [124mm]
[2] 5/8" [16mm] 
dia. holes 
12"
[305mm]
4 7/8"
[124mm]
10 1/2"
[267mm]
6 1/2"
[165mm]
8"
[203mm]
9/16" [14mm]
Dia. Hole [4]
 

COLOR
[add as suffix 
/must specify]
WH=White 
BK=Black 
AP=Grey 
BZ=Bronze 
DP=Dark Platinum 
GM=Graphite Metallic
TLU TALON LARGE
ORDERING INFORMATION
SAMPLE NUMBER: TLU91SWW3VF
BALLAST TYPE 
C=CWI 
H=Reac./HPF 
K=10KV CWA 
M=Mag. Reg.  
N=Hi. Reac./NPF 
P=Hi. Reac./HPF 
R=Reac./NPF 
W=CWA
VOLTAGE 
2=120V 
0=208V 
4=240V 
7=277V 
8=480V 
9=347V 
N=Multi-Tap 
wired 277V
W=Multi-Tap 
wired 120V
V=Multi-Tap 
wired 240V
DISTRIBUTION 
Horizontal Lamp 
2F=Type II Formed 
2S=Type II Segmented
4
3F=Type III Formed 
3S=Type III Segmented
4
4F=Type IV Formed 
4S=Type IV Segmented
4
5F=Type V Formed 
5S=Type V Segmented
4
SL=Spill Light Eliminator
3
Vertical Lamp 
3V=Type III Vertical 
4V=Type IV Vertical  
AR=Area Round 
AS=Area Square 
AF=Automotive Front Row
LENS TYPE 
F=Flat Glass 
S=Sag Glass
PRODUCT 
FAMILY
1
TLU=Talon
Site 
Large
LAMP TYPE 
S=High 
Pressure 
Sodium
R=Super Metal
Halide
M=Metal 
Halide
P=Pulse Start
Metal Halide
LAMP 
WATTAGE 
25=250W 
32=320W
2
35=350W
2
40=400W 
75=750W 
87=875W
2
91=1000W
3
Lamp Type Wattage
Metal Halide
250, 400, 1000W
Pulse Start Metal Halide
250, 320, 350, 400, 450, 750, 875, 1000W
Super Metal Halide
250, 400, 750, 1000W
High Pressure Sodium 250, 400, 1000W
OPTIONS [add as suffix] 
1=Single Fuse [120, 277 or 347V]
5
2=Double Fuse [208, 240 or 480V]
5
3=Three Place Terminal Block  
4=NEMA Twistlock Photocontrol Receptacle 
B=Internal House-side Shield
6
DM=Direct Mount for Pole  
E=Quartz Restrike w/Delay [Also Strikes at Cold Start]
7
H=Plug-in Starter Receptacle
8
HL=Hi/Low Dimming
9
L=Lamp Included 
Q=Quartz Restrike [Hot Restrike Only]
7
U=U.L. Listed 
WM=Wall Bracket with 10 1/2" Arm
OA/RA1016=NEMA Photocontrol [105-285V] 
OA/RA1027=NEMA Photocontrol [480V] 
OA/RA1201=NEMA Photocontrol [347V] 
OA/RA1013=Shorting Cap 
MA1010-XX=Single Tenon Adapter for 3 1/2" O.D. Tenon 
MA1011-XX=2 @ 180° Tenon Adapter for 3 1/2" O.D. Tenon 
MA1012-XX=3 @ 120° Tenon Adapter for 3 1/2" O.D. Tenon 
MA1013-XX=4 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon 
MA1014-XX=2 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon 
MA1015-XX=2 @ 120° Tenon Adapter for 3 1/2" O.D. Tenon 
MA1016-XX=3 @ 90° Tenon Adapter for 3 1/2" O.D. Tenon 
MA1017-XX=Single Tenon Adapter for 2 3/8" O.D. Tenon 
MA1018-XX=2 @ 180° Tenon Adapter for 2 3/8" O.D. Tenon 
MA1019-XX=3 @ 120° Tenon Adapter for 2 3/8" O.D. Tenon 
MA1045-XX=4 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon 
MA1048-XX=2 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon 
MA1049-XX=3 @ 90° Tenon Adapter for 2 3/8" O.D. Tenon 
MA1214-XX=External House-side Shield Kit [EPA=0.94]
OPTIONS + ACCESSORIES [must be ordered in alphanumeric order]
DIMENSIONS
WATTAGE TABLE
IP65 Rated
25° C Ambient Temperature
U.L. 1598 Listed
CSA Listed
ISO 9001
FCO [Full Cutoff] Flat Glass Only
CERTIFICATIONS
DRILLING PATTERNS
TYPE “M” WALL MOUNT
ACCESSORIES [order separately/replace XX with color designation]
OPTIONS + 
ACCESSORIES
[See Below]
NOTES: 1 10 1/2" arm and round pole adapter included with fixture. 2 320/350/875W Pulse Start Metal Halide lamp only. 3 Requires reduced envelope lamp. 4 Maximum wattage on segmented optical 
distributions is 400W. 400W Metal Halide lamp must use reduced envelope ED-28 lamp. 5 Must Specify Voltage. 6 House-side shield not available on 5S, 5F, AS, AR and SL optics. 7 Quartz options not 
available with SL and AF optics. 8 Not available in 1000W. 9 Requires vertical lamp orientation. Provides 24V low voltage leads used in dimming control. 10 Specifications and dimensions subject to change 
without notice.
STANDARD COLORS
GM
Graphite Metallic
WH
White
DP
Dark Platinum
BZ
Bronze
BK
Black
AP
Grey
Effective Projected Area
Without Arm: 1.82
10 1/2" Arm: 0.6
EPA
Approximate Net Weight
400W 91 lbs. [41.36 kgs.]
1000W  98 lbs. [44.54 kgs.]
SHIPPING DATA
14 1/8"
[359mm]
10 1/2"
 [267mm]
21 5/8" [549mm]
3 1/8"
[79mm]
31" [787mm]
2 5/16"
[59mm]
3/4" [20mm] 
dia. hole
2 7/16" [124mm]
4 7/8" [124mm]
[2] 5/8" [16mm] 
dia. holes 
4 7/8"
[124mm]
10 1/2"
[267mm]
6 1/2"
[165mm]
8"
[203mm]
12"
[305mm]
9/16" [14mm]
Dia. Hole [4]
 

Cooper Lighting
Customer First Center 
1121 Highway 74 South 
Peachtree City, GA 30269
P: 770-486-4800 
F: 770-486-4801
www.cooperlighting.com
International Sales, USA
Cooper Lighting 
1121 Highway 74 South 
Peachtree City, GA 30269
P: 770-486-4800 
F: 770-486-4801
Canada
Cooper Lighting 
5925 McLaughlin Road 
Mississauga, Ontario L5R 1B8
P: 905-507-4000 
F: 905-568-7049
The Cooper Lighting Family
Halo 
Metalux 
Lumark 
Sure-Lites 
Neo-Ray 
Corelite 
Portfolio 
Iris 
Shaper 
io 
Lumière 
Invue 
McGraw-Edison 
Streetworks 
Fail-Safe 
MWS 
DLS 
RSA 
Ametrix
Printed in USAADW080322
Domestic Facilities
Cranbury, New Jersey 
Elk Grove Village, Illinois 
Irving, Texas 
Ontario, California 
Peachtree City, Georgia
Canadian Facility
Calgary, Alberta T2E 7V9
Cooper Industries, Ltd.
600 Travis, Ste. 5800 
Houston, TX 77002-1001 
P: 713-209-8400 
www.cooperindustries.com
Cooper Lighting, Streetworks, Talon and Accel Optics are valuable trademarks of Cooper Industries in the United States and other countries. 
You are not permitted to use the Cooper Trademarks without the prior written consent of Cooper Industries.