Warning
that all sources of power are turned off. All
work must meet local/national codes and be
performed by a certified electrician.
mount fixtures vertically.
: Before starting any work ensure
Do not
J-box
(by others)
Canopy
1/4-20 x1"
Aiming screw
Installation Instructions
Sheet 1 of 3
Roundel, XL
INDOOR
PS
(Pendant Swivel)
Visor and Non-Visor
Exploded View and Part Call-Out
Pendant length dependant
Mounting bracket
on order(multiple sections
may be required, consult
factory for coupler and
safety wire installation
requirements).
End cap
#8-32 x.75"
Cap screw
(x2)
3/8-16 x1"
Hex end screw
(x2)
All extra large fixtures require additional bracing/structure around J-box to support fixture.
1.
Securing Power side Pendant to Ceiling
J-box
(by others)
Mounting plate
Appropriate fasteners
(by others)
(x2)
Attention:
2.
Appropriate fasteners
(by others)
(x2)
Fixture door
Securing non-Power side Pendant
Mounting plate
Canopy
1.
Remove canopy and allow it slide down pendant.
2.
Using appropriate fasteners(by others), secure mounting
plate to structure/ bracing around J-box.
3.
For mounting plate dimensions refer to page three(3).
ADY080864 REV B(ECN080377)
Canopy
1.
To mount non-power side pendant, use dimensions provided
on page three(3).
2.
Using appropriate fasteners(by others), secure mounting plate
to structure/ bracing in ceiling.
Warning
that all sources of power are turned off. All
work must meet local/national codes and be
performed by a certified electrician.
mount fixtures vertically.
: Before starting any work ensure
Do not
Installation Instructions
Sheet 2 of 3
Roundel, XL
INDOOR
PS
(Pendant Swivel)
Visor and Non-Visor
3. 4.
1/4-20 x1"
Aiming Screw
(x2)
Fixture wire
1.
After hanging both pendants, carefully lift fixture head into
place.
2.
Secure fixture using both 3/8 -16 x 1" End screws.
3.
Secure desired angle using 1/4-20 x 1" Aiming screws.
5.
Mounting Fixture to Pendants
Canopy
Fixture wire
3/8-16 x1"
End Screw
(x2)
1.
up pendant tube to J-box.
2.
matched.
3.
Securing Safety Wires and Aiming the Fixture
Wiring the Fixture
After securing the fixture head to the pendants, run fixture wire
Attach appropriate wires ensuring all connections are properly
Secure canopy to mounting plate.
#8-32 x.75"
End Screw
(x2)
1/4"-20 safety wire
connector
(x2)
End Cap
1.
To secure safety wire to fixture, screw 1/4"-20 wire connector to bottom of pendant bracket.
2.
Run safety wire up pendant tube and secure to structure in ceiling.
3.
To adjust angle of fixture head, loosen both 1/4-20 x1" aiming screws.
4.
Rotate fixture head to desired angle and secure with both 1/4-20 x1" aiming screws.
5.
Replace end cap using 8-32 x.75" end screw.
J-box hidden
for clarity
40
Side view
ADY080864 REV B(ECN080377)