Cooper Lighting ADY071451 User Manual

Vault
These installation instructions valid with the above Ametrix styles.
C-Scroll
Roundel
Installation Instructions
Sheet 3 of 5
Small, OUTDOOR
CYI
(Continuous, Yoke mount, Integral ballast)
Visor and Non-Visor
Warning
that all sources of power are turned off. All work must meet local/national codes and be performed by a certified electrician.
: Before starting any work ensure
4
Center hub assembly
1. Remove gasket and cover plate from center hub assembly.
2. Feed wire from new fixture into center hub assembly.
3. Secure fixture head with both #6-32 x1/4" tapered set screws.
4. Attach all wires and ensure all connections are properly matched.
5. Hide wires in hub assembly and re-attach cover plate and gasket.
6
Attaching fixture to center hub assembly Attaching fixture to end hub assembly
Gasket
Cover plate and gasket
Powerside fixture
Hub end cap
#6-32 x1/4" Tapered set screw (x2)
Ensuring the fixtures are sealed for outdoor use
5
Final hub assembly
#6-32 x1/4" Final fixture in run
Hub end cap
Hub gasket
1. To end run, secure fixture head to end hub assembly inserting hub cap and securing both #6-32 x1/4" tapered set screw end screw.
2. Replace end cap and gasket and secure with #6-32 x1/4" tapered set screws.
Tapered set screw
(x4)
End cap
Hub gasket
Hub gasket
#6-32 x1/2" Socket cap screw
#6-32 x1/4" Tapered set screw (x4)
1. Ensure all socket cap screws are tightened to 10 in/lbs. (For proper torque sequence refer to supplemental page)
2. Ensure all hub caps are secured with two #6-32 x.25 tapered set screws to ensure proper compression of the hub gaskets.
3. Ensure a proper seal between the hub assembly mounting plate and the outdoor surface.
ADY071451 REV A(ECN070306)
#6-32 x5/8" Socket cap screw
#6-32 x5/8" Socket cap screw
#6-32 x1/2" Socket cap screw
#6-32 x5/8" Socket cap screw
Vault w/ visor
These installation instructions are valid with the above Ametrix styles
C-Scroll w/ visor
Roundel w/ visor
Installation Instructions
Sheet 4 of 5
Small, OUTDOOR
CYI
(Continuous, Yoke mount, Integral ballast)
Visor and Non-Visor
Warning
that all sources of power are turned off. All work must meet local/national codes and be performed by a certified electrician. mount fixtures vertically.
: Before starting any work ensure
Do not
27
2
32
72.39
(Dimensions are valid for both power, end and center(shown) hub mounting plates)
Mounting Plate Dimensions
in [mm]
133.35
1
4
"
2
114.30
"
21
7 "
32
194.64
Standard Length
1
5
"
4
Front View of mounting plate
1
"
4
6.35
Side View
9
3
"
16
90.42
ADY071451 REV A(ECN070306)
2"
50.80
Top View
Vault w/ visor
Actual
Actual
These installation instructions are valid with the above Ametrix styles
C-Scroll w/ visor
Continuous Row Layouts
Roundel w/ visor
Installation Instructions
Sheet 5 of 5
Small, OUTDOOR
CYI
(Continuous, Yoke mount, Integral ballast)
Visor and Non-Visor
Warning
that all sources of power are turned off. All work must meet local/national codes and be performed by a certified electrician. mount fixtures vertically.
: Before starting any work ensure
Do not
Nominal Row Length (ft)
3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
Overall Row Length: Outdoor (ft)
Row Breakdown/ Installation Sequence
2.6 2C
3.6 3C
4.6 4C
5.1 2C,2C
6.1 2C,3C
7.1 3C,3C
8.1 3C,4C
9.1 4C,4C
10.7 3C,3C,3C
11.7 4C,2C,4C
12.7 4C,3C,4C
13.7 4C,4C,4C
14.2 3C,3C,3C,3C
15.2 3C,3C,3C,4C
16.2 3C,4C,4C,3C
17.2 4C,4C,4C,3C
18.2 4C,4C,4C,4C
19.8 4C,3C,3C,3C,4C
20.8 3C,4C,4C,4C,3C
21.8 4C,4C,3C,4C,4C
21.8 4C,4C,3C,4C,4C
23.4 2C,4C,4C,4C,4C,2C
23.4 2C,4C,4C,4C,4C,2C
25.4 3C,4C,4C,4C,4C,3C
Nominal Row Length (ft)
27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
Overall Row Length: Outdoor (ft)
Row Breakdown/ Installa tion Sequence
25.4 3C,4C,4C,4C,4C,3C
27.4 4C,4C,4C,4C,4C,4C
28.9 4C,4C,3C,3C,3C,4C,4C
29.9 3C,4C,4C,4C,4C,4C,3C
30.9 4C,4C,4C,3C,4C,4C,4C
31.9 4C,4C,4C,4C,4C,4C,4C
31.9 4C,4C,4C,4C,4C,4C,4C
32.5 2C,4C,4C,4C,4C,4C,4C,2C
34.5 3C,4C,4C,4C,4C,4C,4C,3C
35.5 4C,4C,4C,4C,3C,4C,4C,4C
36.5 4C,4C,4C,4C,4C,4C,4C,4C
38.0 4C,4C,4C,3C,3C,3C,4C,4C,4C
39.0 3C,4C,4C,4C,4C,4C,4C,4C,3C
39.0 3C,4C,4C,4C,4C,4C,4C,4C,3C
40.0 4C,4C,4C,4C,3C,4C,4C,4C,4C
41.0 4C,4C,4C,4C,4C,4C,4C,4C,4C
42.6 4C,4C,4C,4C,3C,3C,3C,4C,4C,4C
43.6 3C,4C,4C,4C,4C,4C,4C,4C,4C,3C
44.6 4C,4C,4C,4C,4C,3C,4C,4C,4C
45.6 4C,4C,4C,4C,4C,4C,4C,4C,4C,4C
46.1 3C,3C,4C,4C,4C,4C,4C,4C,4C,3C,3C
47.1 4C,4C,4C,4C,3C,3C,3C,4C,4C,4C,4C
48.1 3C,4C,4C,4C,4C,4C,4C,4C,4C,4C,3C
49.1 4C,4C,4C,4C,4C,3C,4C,4C,4C,4C,4C
ADY071451 REV A(ECN070306)
Loading...