SHAPER
18" ø
4-1/2"
8"
14" ø
12" ø
5-3/4"
28" ø
4"
8-1/2"
12" ø
5-3/4"
3-3/4"
8-1/4"
24" ø
12" ø
5-3/4"
™
RECESSED PENDANTS
420-RP SERIES
420-RP features an 18" pendant
designed for low ceiling applications
and offers performance optics by
Portfolio.
Sample Number: 420-RP-CFL/2/32-347V-SAL
Series
420-RP =18" Pendant
445-RP SERIES
445-RP features a 28" pendant
designed for low ceiling applications
and offers performance optics by
Portfolio.
Sample Number: 445-RP-CFL/2/32-347V-PC
Series
445-RP =28" Pendant
Lamp
CFL/2/26
CFL/2/32
CFL/2/42
Lamp
CFL/2 /26
CFL/2 /32
CFL/2 /42
Voltage
120V
277V
347V
Voltage
120V
277V
347V
Finish
NA (standard),
CC, MW, SAL
Finish
MW (standard),
CC, PB, PC, PCP,
SB, SC, SCL, SCP,
SN, SNL
Options
DL
EM
Options
DL
EM
FB
MATERIAL
Painted or natural
aluminum supplied with
an aluminum cube cell
louver, painted white.
LAMP/SOCKET
Two (2) 26W, 32W
(GX24q-3) or 42W
(GX24q-4) 4-pin triple
CFL lamps. Universal
4-pin CFL socket injection
molded plastic with guide
post inserts reject 2-pin
lamp to ensure proper
lamping. Lamps
furnished by others.
FINISH AND OPTIONS
See page 1020 for finish
details and options.
MATERIAL
Painted or plated cold
rolled steel trim ring with
a matte white acrylic
bowl.
LAMP/SOCKET
Two (2) 26W, 32W
(GX24q-3) or 42W
(GX24q-4) 4-pin triple CFL
lamps. Universal 4-pin
CFL socket injection
molded plastic with guide
post inserts reject 2-pin
lamp to ensure proper
lamping. Lamps
furnished by others.
FINISH AND OPTIONS
See page 1020 for finish
details and options.
BALLAST/EMERGENCY BATTERY PACK
One (1) integral multi-voltage (120V/277V)
electronic CFL (347V Canada) ballast for a 26W,
32W or 42W CFL lamp. Optional - One (1) integral
emergency battery pack option (EM) is shipped
pre-wired. Sealed Ni-Cad battery powers CFL
lamps for 90 minutes of emergency illumination.
Integral test switch/ indicator light is located
inside the reflector, out of view but easily
accessible for testing.
INSTALLATION
Recessed mounting requires 9" (23cm) diameter
by 6 3/8" (16cm) deep opening in ceiling.
Accommodates ceilings up to 2" (5 cm) thick. No
Fuss Bar Hangers (tm) and T-Bar provided with
centering mechanism that allows consistent
centering of luminaire. Thermal protection
deactivates unit if improper lamp type or
wattage is used or if insulation is placed too
close to the housing. Decorative trim/bowl
assembly is securely suspended from the
mounting ring by three stainless steel cables
(provided). No cutting or adjustment of cables is
required to achieve standard overall height and
level mounting.
BALLAST/EMERGENCY BATTERY PACK
One (1) integral multi-voltage (120V/277V)
electronic CFL (347V Canada) ballast for 26W,
32W or 42W CFL lamps. One (1) integral
emergency battery pack option (EM) is shipped
pre-wired. Sealed Ni-Cad battery powers CFL
lamps for 90 minutes of emergency
illumination. Integral test switch/indicator light
is located inside the reflector, out of view but
easily accessible for testing.
INSTALLATION
Recessed mounting requires 9" (23cm) diameter
by 6 3/8" (16cm) deep opening in ceiling.
Accommodates ceilings up to 2" (5 cm) thick. No
Fuss Bar Hangers (tm) and T-Bar provided with
centering mechanism that allows consistent
centering of luminaire. Thermal protection
deactivates unit if improper lamp type or
wattage is used or if insulation is placed too
close to the housing. Decorative trim/bowl
assembly is securely suspended from the
mounting ring by three stainless steel cables
(provided). No measuring, cutting or adjustment
of cables is required to achieve standard overall
height and level mounting.
494-RP SERIES
494-RP features a 24" pendant
designed for low ceiling applications
and offers performance optics by
Portfolio.
COOPER LIGHTING
956
Sample Number: 494-RP-CFL/2/32-347V-PC
Series
494-RP =24" Pendant
Lamp
CFL/2/26
CFL/2/32
CFL/2/42
Voltage
120V
277V
347V
Finish
MW (standard),
CC, PB, PC, PCP,
SB,SC, SCL, SCP,
SN, SNL
Options
DL
EM
FB
MATERIAL
Painted or plated cold
rolled steel trim ring with
a matte white acrylic
bowl.
LAMP/SOCKET
Two (2) 26W, 32W
(GX24q-3) or 42W
(GX24q-4) 4-pin triple CFL
lamps. Universal 4-pin
CFL socket injection
molded plastic with guide
post inserts reject 2-pin
lamp to ensure proper
lamping. Lamps
furnished by others.
FINISH AND OPTIONS
See page 1020 for finish
details and options.
BALLAST/EMERGENCY BATTERY PACK
One (1) integral multi-voltage (120V/277V)
electronic CFL (347V Canada) ballast for 26W,
32W or 42W CFL lamps. One (1) integral
emergency battery pack option (EM) is shipped
pre-wired. Sealed Ni-Cad battery powers CFL
lamps for 90 minutes of emergency illumination.
Integral test switch/indicator light is located
inside the reflector, out of view but easily
accessible for testing.
INSTALLATION
Recessed mounting requires 9" (23cm) diameter
by 6 3/8" (16cm) deep opening in ceiling.
Accommodates ceilings up to 2" (5 cm) thick. No
Fuss Bar Hangers (tm) and T-Bar provided with
centering mechanism that allows consistent
centering of luminaire. Thermal protection
deactivates unit if improper lamp type or
wattage is used or if insulation is placed too
close to the housing. Decorative trim/bowl
assembly is securely suspended from the
mounting ring by three stainless steel cables
(provided). No measuring, cutting or adjustment
of cables is required to achieve standard overall
height and level mounting.