SPECIFICATION FEATURES
08/02/2008 12:56:40 PM
Consult your representative for additional options and finishes.
Specifications and Dimensions subject to change without notice.
ADF070949
MOUNTING DATA
LAMP CONFIGURATIONS
CEILING COMPATIBILITY
DESCRIPTION
The accord(TM) redefines fluorescent lighting by improving on aesthetics,
comfort and energy savings. The accord(TM) provides the right amount of
light while eliminating surface shadows commonly found in parabolics.
Therefore, accord(TM) increases the comfort level while providing
significant energy savings.
The accord(TM) is the ideal solution for offices, schools, hospitals, retail and
other applications.
A ... Construction
Shallow 3-1/4" deep housing is die
formed of code gauge, prime cold
rolled steel. Heavy gauge end
plates are securely attached with
screws for strength and rigidity
and the elimination of gaps. Four
auxiliary fixture end suspension
points are provided. KOs for
continuous row wiring. Large
access plate for supply connection.
B ... Electrical*
Ballasts are Class "P" and are
positively secured. UL/CUL listed.
Suitable for damp locations.
C ... Ballast Access
Ballast can be removed from
below without tools.
D ... Finish
Durable cold rolled steel with
multistage, iron phosphate
pretreatment and white enamel
finish to ensure maximum bonding
and rust inhibition.
E ... Reflectors
Reflector has high reflectance
baked matte white enamel finish
for luminous uniformity.
F ... Shielding
Positiviely retained frosted acrylic
profile lenses provide a soft but
effective distribution of light.
G ... Air Return
Optional Air Return model
provides air flow through air slots
in the housing.
2AC
2BX40
COMPACT
FLUORESCENT LAMPS
2' x 2' Recessed
Troffer Series
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power
23-3/4"
[603 mm]
3-1/4"
[83mm]
A
B C D FE
EB Ballast & STD Lamps @ 120V
2BX40T5 (78)
Luminaire Efficacy Rating
LER =FL56 Catalog Number: 2AC-2BX40
Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.28
*Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements.
**Consult Pre Sales Technical Support.
***See Drywall Frame Kit Accessory
E N ER G Y DAT A
Input Watts:
Access Plate
23-3/4"
[603mm]
24" [610mm]
3-1/16"
[78mm]
3-3/8"
[86mm]
1-1/2"
[39mm]
23-3/4" [603mm]
3-1/4"
[83mm]
11-3/4" [298mm]
G
Grid/Lay-in Standard
F
Drywall Frame Kit
Ceiling Trim Type** Type
Exposed Grid G Concealed T G or T Slot Grid G or T Flange ***
COOPER LIG HT IN G - ME TA LU X
®
Specifications and Dimensions subject to change without notice.
PHOTOMETRICS
ORDERING INFORMATION
SHIPPING DATA
2BX40
2AC
C o e ffi c ie nt s of U ti li za ti on
Effective floor cavity reflectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0 1 2 3 4 5 6 7 8 9
10
Z o n al L um en S um ma ry
Zone Lumens %Lamp %Fixture 0-30 0-40 0-60 0-90 0-180
||
C a n de la
Angle Along II 45° Across
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
2AC-2BX40
Electronic Ballast (2) F40BX lamps
3000 lumens Spacing criterion:
(II) 1.3 x mounting height, ( ) 1.4 x mounting height
Efficiency 79.6% Test Report:
241P137 LER = FL-58 Yearly Cost of 1000
lumens, 3000 hrs at .08 KWH = $4.28
1558 1558 1558 1555 1554 1558 1537 1541 1545 1508 1516 1526 1463 1481 1497 1405 1435 1459 1336 1380 1415 1256 1316 1362
1167 1244 1302
1068 1162 1232
960 1072 1152 843 973 1059 717 864 926 586 743 751 449 580 571 312 406 391 186 237 218
81 84 68
0 0 0
95 95 95 95 93 93 93 93 88 88 88 85 85 85 81 81 81 80 86 82 79 75 84 80 77 74 77 74 72 74 72 70 71 69 68 66 78 71 65 61 76 70 64 60 67 62 58 64 60 57 62 59 56 54 71 62 55 50 69 61 54 49 58 53 48 56 51 48 54 50 47 45 65 55 47 42 63 54 47 41 51 46 41 50 44 40 48 43 40 38 59 49 41 36 57 48 41 35 46 40 35 44 39 35 43 38 34 33 55 44 36 31 53 43 36 31 41 35 30 40 34 30 39 34 30 28 50 39 32 27 49 39 32 27 37 31 27 36 31 27 35 30 26 25 47 36 29 24 46 35 29 24 34 28 24 33 28 24 32 27 24 22 44 33 26 22 43 32 26 22 31 26 21 31 25 21 30 25 21 20 41 30 24 19 40 30 24 19 29 23 19 28 23 19 28 23 19 18
1238 19.7 24.7 2061 32.7 41.1 3814 60.5 76.0 5016 79.6 100.0 5016 79.6 100.0
L u m in an ce D at a
Average Average Average Angle 0-Deg 45-Deg 90-Deg in Deg cd/sm cd/sm cd/sm
45 4238 4611 4888 55 4124 4759 5180 65 3890 4933 4986 75 3382 4401 4239 85 2608 2704 2189
S A M PL E NU MB ER : 2A C- 2 BX 40 -1 20 -E B5 1 -U
Voltage
1
UNV=Universal
120= 120V 277= 277V
Options GL=Single Element Fuse GM=Double Element Fuse Flex=Flex installed EL=Emergency Installed
Packaging U=Unit Pack PALC=Job Pack,
in carton
Shielding Blank=Frosted Acrylic SQP=Lens with Square
Pattern Insert RDP=Lens with Round Pattern Insert
NOTES:
1
Products also available in non-US voltages and frequencies for international markets.
Specifications & dimensions subject to change without notice. Consult your
Ballast Type EB5
=T5 Biax Electronic Instant Start.
Total Harmonic Distortion < 20%
No. of Ballast 1
Number of Lamps
(Not included)
2=2 Lamp
Wattage (Length) BX40=40W Compact
Fluorescent (24")
Series AC=Accord Series
Width 2=2' Width
Rating Blank=
Standard NY=New York Rated ATW-SW4= Chicago Rated
Type A=Air (optional)
2
For universal voltage, program Rapid Start ballast must be specified.
Cooper Lighting Representative for availability and ordering information.
LB35=Biax lamp, 40W, 3500K
LB41=Biax lamp, 40W, 4100K
(Dedicated voltage required)
2
2AC-2BX40 28 lbs.
Catalog No. Wt.
Metalux • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
08/02/2008 12:56:40 PM
ADF070949
Loading...