Cooper Lighting 1499, MAF User Manual

FAIL-SAFE
A
B
MEDICAL/TASK & UNDERCABINET
®
DIMENSIONS
CEILING OPENING DOOR FRAME
ABC D
MAF 4" 10 3/4" 11 1/16" 48 5/16"
1'x 4' (102mm) (273mm) (281mm) (1227mm)
MAF 3 3/4" 22 11/16" 23 1/16" 24 5/16" 2'x 2' (95mm) (576mm) (586mm) (617mm)
MAF 3 3/4" 22 11/16" 23 1/16" 48 5/16" 2'x 4' (95mm) (576mm) (586mm) (617mm)
ORDERING INFORMATION
SAMPLE NUMBER: MAF-24-632-277-ASY/SYM-EB82-GLR
Product Family MAF=Medical
Asymmetric / Symmetric Fluorescent Flange
Width 12=12" 24=24"
Lamp Type
2' Fixture Length
T8 Fluorescents 117=(1) 17W Lamp 217=(2) 17W Lamps 317=(3) 17W Lamps 417=(4) 17W Lamps
T12 Fluorescents 120=(1) 20W Lamp 220=(2) 20W Lamps 320=(3) 20W Lamps 420=(4) 20W Lamps
U Lamps 2U 1 5/8=(2)31W T8 Lamps 3U 1 5/8=(3) 31WT8 Lamps 2U6T8=(2) 32WT8 Lamps 2U6=(2)40WT12Lamps
Biaxial Fluorescents 140BX=(1) 40W Lamp 240BX=(2) 40W Lamps 340BX=(3) 40W Lamps
4' Fixture Length
T8 Fluorescents 132=(1) 32W Lamp 232=(2) 32W Lamps 332=(3) 32W Lamps 432=(4) 32W Lamps 632=(6) 32W Lamps
T12 Fluorescents 140=(1) 40W Lamp 240=(2) 40W Lamps 340=(3) 40W Lamps 440=(4) 40W Lamps
3
Voltage 120=120V 277=277V 347=347V UNV=120V through 277V
Lens Type IK12=K-12 Prismatic
Acrylic
IP12=K-12 Prismatic
Polycarbonate
1
=Bat Wing
KSH25
Distribution
ASY/SYM=Asymmetric /
Symmetric Lens
ASY/SYM/RFI=Asymmetri
c / Symmetric Lens with RFI grid
Ballast LE3=Energy Saving
Ballast for use with T12 lamp
Electronic Ballast EB81=(1) Ballast for use
with T8 Lamp
EB82=(2) Ballasts for use
with T8 Lamp
EB21=(1) Ballast for use
with T12 Lamp
EB22=(2) Ballasts for use
with T12Lamp
EBX1=(1) Ballast for use
with Biaxial Lamp
EBX2=(2) Ballasts for use
with Biaxial Lamp
NOTE:
Electronic ballast not rec­ommended for surgical suites. Electronic ballast will nullify all RFI shielding. Please specify LE3 or LEOC8 ballast option
Door/Finish Options Blank=Standard, CRS with
baked white finish
SSN=Stainless Steel Door/
Brushed 304 Finish
SSP=Stainless Steel Door/
Polyester Powder Coat Finish
ALXP=Extruded
Aluminum/Polyester Powder Coat Finish
ALP=Formed
Aluminum/Polyester Powder Coat Finish
ALX=Extruded
Aluminum/Anodized
DESCRIPTION
The Fail-Safe MAF Series is designed for use in horizontal or non-laminar air flow clean rooms. The enclosed and gasketed housing and one­piece, outside flanged door protect against infiltration of airborne bacteria. The die formed edges on the door frame and the hole-free design of the housing prevent air exchange between the fixture and plenum, allowing relamping without contamination of the clean areas. These luminaires are U.L. listed and C.S.A. certified for wet locations and are manufactured in accordance with U.S.D.A., F.D.A., N.S.F. and Federal Standard 209E. The MAF Series is suitable for use in I.E.S. Class 100, 1,000, 10,000 and 100,000 clean room environments.
Options EBP=Emergency
Battery Pack
GLR=Fuse and
2, 4
Accessories
(Order Separately)
MFCF12-2FT=2FT Mounting
MFCF12-4FT=4FT Mounting
MFCF24-2FT=2FT Mounting
MFCF24-4FT=4FT Mounting
Holder
RIF=Radio
Frequency Interference Filter
Housing Options SHN=Stainless
Steel, Brushed 304 Finish
SHP=Stainless
Steel, Polyester Powder Finish
ALH=Aluminum,
Polyester Powder Finish
Frame
Frame
Frame
Frame
MAF
17W–240W
Fluorescent
1' X 4', 2' x 2', 2' x 4'
FLUORESCENT FLANGE
SYMMETRIC/
ASYMMETRIC LENS
ONE-PIECE DOOR
SOLID CEILING
PLASTER OR
DRYWALL
• Rated for high pressure hose down at 200 PSI
Flush mounted, stainless steel machine screws
Unique, Particulock™ lens retention system utilizes continuous, 18 ga. media clampdowns
Two braided, stainless steel cables on one side of door provide hinging
One-piece, 18 ga., fully gasketed, outside flanged door
Standard Class P, CBM/ETL ballast
White, closed cell,
Flexiseal™ gasketing system
* Gasketed access plate with
two flattened, 7/8" diameter knockouts
Notes: For additional options, consult your Cooper Lighting Representative. Specifications and Dimensions subject to change without notice.Electronic ballast may cause interference with other electronic devices. If interference occurs move the device away from the product or plug/connect into a different circuit/outlet.
1
The KSH25 provides improved visual performance and wide angle distribution. This lens has an integral prism pattern designed so that
prisms face the lamp cavity and still supply superior photometrics. Highly recommended for all high tech manufacturing environments.
2
For specific electronic ballast, specify brand and catalog number. 3Products available in non-US voltages and 50 Hz for international markets. Consult your Cooper Lighting Representative for availability and ordering information. lamps.
4
Electronic ballast not available with 20W
COOPER LIGHTING
1499
Loading...