WSC 4329 WIRELESS CELLMITE
®
he WSC 4329 wireless signal conditioner directly connects to
standard strain gage load cells or pressure transducers. Wireless
T
signals can reach up to 1500 feet. The system consists of the
WSC 4329 which connects to the load cell and also offers a 0-10Vdc
output which may be connected to a digital display. The WSC 4329M
directly connects to a PC with RS232. Monitor and control networked
units with Graphical User Interface (GUI).
The WSC 4329 also features a nonvolatile memory for parameter and
calibration storage, the ability to select between three transducers, multipoint and mV/V calibration, remote sense excitation, and a 24-bit
internal resolution with 16-bit analog output. The WSC 4329 compensates for transducer nonlinearities using its integrated 6-point calibration. Its wireless communication port and simple command set allows
for easy set up.
APPLICATION
• STORES CALIBRATION DATA FOR
3 SENSORS
• SETUP A TEST TO START AND STOP
AUTOMATICALLY
• USER PROGRAMMABLE ANALOG OUTPUT
• 60 SAMPLES PER SECOND
• 6 POINT LINEARIZATION CALIBRATION
WSC 4329
DIGITAL FORCE INDICATOR
SPECIFICATIONS
GENERAL
• CHANNELS 1
• TEMPERATURE: Internal Temperature compensation
• MATERIAL Plastic Case
• POWER: 110/240VAC,
Optional 4340 Rechargeable Battery
Pack
Compatible with 4 x AA NiMH
• PEAK HOLD: Tare and Reset Peak and Valley
• RELAY Solid State
TRANSDUCER
• EXCITATION: Voltage: 5 VDC. Nom. Load 350 Ω
• INPUTS ±5.5 mv/v
• CALIBRATION METHOD: 6 Pt Linearization, 2Pt, Shunt Cal
AMPLIFIER
• OUTPUTS: Analog: 16-bit Scalable, ±10V.
Serial Data: Multi-drop RS232
• STORAGE: For three calibrated load cells.
• UNITS: LB, Kg, In, Cm, %, User-Defined
• RESOLUTION: 24-bit internal resolution,
error 0.01%, ±1 count.
• WIRELESS: Nominal Frequency 900 MHz
Classification: Mobile
This device complies with Part 15
of the FCC Rules.
COOPER INSTRUMENTS & SYSTEMS
PHYSICAL
• DIMENSIONS: 5.5" x 2.75" x 1.2".
• WEIGHT: 8.9 oz (252g).
SOFTWARE
• CellViewLite (CellView Multi-Display for up to 4 Units).
• Guides user through adding/removing WSC Units.
• Stores calibration data for three sensors.
• Guides user through sensor calibrations.
• Tare and reset peak and valley for the sensor.
• Set output data with a quadratic filter.
• Save/Load the WSC unit and sensor setup information.
• Setup a test to start and/or stop automatically.
• LEDs indicate operational status of the GUI.
• Save data, calibration, and sensor test information to spreadsheets.
• Control ouput with relay switch.
• User programmable analog output voltage.
www.cooperinstruments.com sales@cooperinstruments.com
1-800-344-3921